Specifications

Pressure Sensor Type
pressure transmitter
Range Of Product
Telemecanique Pressure sensors XM
Pressure Switch Type Of Operation
pressure transmitter with 1 switching output
Product Or Component Type
electronic pressure sensors
Fluid Connection Type
1/4" - 18 NPT (female)
Pressure Sensor Size
3620 psi || 250 bar
Controlled Fluid
fresh water 0-80 °C) || air -20-80 °C) || hydraulic oil -20-80 °C) || refrigeration fluid -20-80 °C)
Maximum Permissible Accidental Pressure
10875 psi || 75 MPa || 750 bar
[Us] Rated Supply Voltage
24 V DC SELV 17-33 V)
Destruction Pressure
1500 bar || 150 MPa || 21750 psi
Device Short Name
XMLR

Complementary

Display Accuracy
<= 1 % of the measuring range
Electrical Connection
male connector M12, 4 pins
Height
88 mm
Accuracy
<= 1 % of the measuring range
Linearity Error
<= 0.5 % of the measuring range
Type Of Output Signal
analogue + discrete
Display Response Time Type
fast 50 ms || normal 200 ms || slow 600 ms
Maximum Voltage Drop
2 V
Repeat Accuracy
<= 0.2 % of the measuring range
Drift Of The Zero Point
+/- 0.1 % of measuring range/°C
Time Delay Range
0...50 s in steps of 1 second
Electromagnetic Compatibility
susceptibility to electromagnetic fields 10 V/m 80...2000 MHz EN/IEC 61000-4-3 || immunity to conducted RF disturbances 10 V 0.15...80 MHz EN/IEC 61000-4-6 || surge immunity test 1 kV EN/IEC 61000-4-5 || electrical fast transient/burst immunity test 2 kV EN/IEC 61000-4-4 || electrostatic discharge immunity test 8 kV air, 4 kV contact EN/IEC 61000-4-2
Maximum Switching Current
250 mA
Adjustable Range Of Switching Point On Falling Pressure
181-3516 psi || 12.5-242 bar || 1.25-24.2 MPa
Operating Position
any position, but disposals can falsified the measurement in case of upside down mounting
Materials In Contact With Fluid
316L stainless steel
Net Weight
0.186 kg
Minimum Differential Travel
0.75 MPa || 109 psi || 7.5 bar
Current Consumption
<= 50 mA
Contacts Type And Composition
NO/NC programmable
Maximum Delay First Up
300 ms
Analogue Output Function
4...20 mA
Scale Type
fixed differential
Local Signalling
for light ON when switch is actuated 1 LED (yellow)
Mechanical Durability
10000000 cycles
Housing Material
polyacrylamide || 316L stainless steel
Measurement Accuracy
<= 0.6 % of the measuring range
Protection Type
overvoltage protection || short-circuit protection || reverse polarity || overload protection
Adjustable Range Of Switching Point On Rising Pressure
2-25 MPa || 20-250 bar || 290-3625 psi
Drift Of The Sensitivity
+/- 0.03 % of measuring range/°C
Width
41 mm
Display Type
4 digits 7 segments
Front Material
polyester
[Uimp] Rated Impulse Withstand Voltage
0.5 kV DC
Hysteresis
<= 0.2 % of the measuring range
Depth
42 mm
Response Time On Output
<= 10 ms analog output || <= 5 ms discrete output
Discrete Output Type
solid state NPN, NO/NC programmable

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
cULus || EAC
Ambient Air Temperature For Operation
-20-80 °C
Standards
UL 61010-1 || EN/IEC 61326-2-3
Shock Resistance
50 gn EN/IEC 60068-2-27
Marking
CE
Vibration Resistance
20 gn 10-2000 Hz)EN/IEC 60068-2-6
Ip Degree Of Protection
IP65 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60529
Ambient Air Temperature For Storage
-40-80 °C