Schneider Electric
XPSABV11330P
1 / 6
Description
Active Mature
This XPSABV safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of PL e/Category 4 (instantaneous safety outputs), PL d/Category 3 (time delayed safety outputs) conforming to EN/ISO 13849-1. It meets also the requirements of SILCL3 (instantaneous safety outputs) and SILCL2 (time delayed safety outputs) conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring Emergency stop circuits conforming to EN/ISO 13850 and EN/IEC 60204-1 standards, and electrical monitoring of switches in protection devices conforming to EN/ISO 14119 standard. It has removable terminals for easier and better control wires tightening, thus improving installation reliability.- Country of Origin
- DE
- Part Number
- XPSABV11330P
- Tariff Code
- 85364190
- EAN
- 3389118376083
- UNSPSC
- 32151802
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 50 pcs.In-StockUpdated at: 22-11-2024
- Warranty:
- 12 months
- Estimated Delivery:
- On Request
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Specifications
- [Us] Rated Supply Voltage
- 24 V DC - 15...10 %
- Range Of Product
- Preventa Safety automation
- Product Or Component Type
- Preventa safety module
- Safety Module Name
- XPSABV
- Output Type
- relay instantaneous opening, 2 NO, volt-free || relay time delay opening, 1 NO, volt-free
- Connections - Terminals
- captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end || captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end || captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel || captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel || captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable end || captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² flexible without cable end || captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel || captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1 mm² flexible with cable end, with double bezel
- Number Of Additional Circuits
- 0
- Safety Module Application
- for emergency stop and switch monitoring
- Safety Reliability Data
- MTTFd = 53 years instantaneous safety outputs EN/ISO 13849-1 || MTTFd = 53 years time delay safety outputs EN/ISO 13849-1 || DC > 99 % instantaneous safety outputs EN/ISO 13849-1 || DC = 60...90 % time delay safety outputs EN/ISO 13849-1 || PFHd = 3E-8 1/h instantaneous safety outputs EN/IEC 62061 || PFHd = 2E-7 1/h time delay safety outputs EN/IEC 62061
- Safety Level
- can reach PL d/category 3 time delay safety outputs EN/ISO 13849-1 || can reach PL e/category 4 instantaneous safety outputs EN/ISO 13849-1 || can reach SILCL 3 instantaneous safety outputs EN/IEC 62061 || can reach SILCL 2 time delay safety outputs EN/IEC 62061
Contractual warranty
- Warranty
- 18 months
Complementary
- [Uc] Control Circuit Voltage
- 24 V DC
- Mounting Support
- 35 mm symmetrical DIN rail
- Output Thermal Current
- 6 A instantaneous and time delay outputs
- Minimum Output Voltage
- 17 V relay output
- Minimum Output Current
- 10 mA relay output
- [Ith] Conventional Free Air Thermal Current
- 12 A
- Associated Fuse Rating
- 6 A gG instantaneous and time delay outputs
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV III IEC 60947-5-1 || 4 kV III DIN VDE 0110 part 1
- Net Weight
- 0.28 kg
- Time Delay Range
- 0.15...3 s || 1.5...30 s
- [Ui] Rated Insulation Voltage
- 300 V 2)IEC 60947-5-1 || 300 V 2)DIN VDE 0110 part 1
- Local Signalling
- 3 LEDs
- Input Protection Type
- internal, electronic
- Synchronisation Time Between Inputs
- < 0.5 s
- Breaking Capacity
- 1.5 A 24 V DC-13)50 ms relay output
- Maximum Power Consumption In W
- 3 W
- Maximum Response Time On Input Open
- 200 ms
- Breaking Capacity
- 3600 VA inrush AC-15 B300 || 360 VA holding AC-15 B300
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1406024EN
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI1406024EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- UL || BG || CSA
- Ambient Air Temperature For Operation
- -25-55 °C
- Standards
- EN/IEC 60947-5-1 || EN 1088/ISO 14119 || EN/ISO 13850 || EN/IEC 60204-1
- Ip Degree Of Protection
- IP20EN/IEC 60529 || IP40EN/IEC 60529
- Ambient Air Temperature For Storage
- -25-75 °C