- [Us] Rated Supply Voltage
- 24 V DC - 20...20 %
- Range Of Product
- Telemecanique Safety light curtains XUSL
- Product Or Component Type
- safety module
- Number Of Inputs
- 2 MA, MB)muting function || 4 Z1, Z2, Z3, Z4)sensor
- Safety Module Name
- XPSCM
- Output Type
- relay 2 NO 13-14, 23-24), volt-free
- Connections - Terminals
- captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid or flexible without cable end || captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel || captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel || captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid or flexible without cable end || captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel || captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
- Input Compatibility
- XC limit switch muting function || XU2M18PP340... muting function || XU2S18PP340... (infrared) sensor || XU9M18PP340... muting function
- Number Of Additional Circuits
- 0
- Input Voltage
- 24 V DCsensor || 24 V DC U+, U-)muting function
- Safety Module Application
- for monitoring of single beam photo-electric sensor
- Safety Reliability Data
- MTTFd = 16.6 years EN/ISO 13849-1 || DC = 95.5 % EN/ISO 13849-1 || PFH = 3.12E-7 1/h EN/IEC 61508 || PFHd = 3.12E-7 1/h EN/IEC 62061
- Function Of Module
- built-in muting
- Safety Level
- can reach category 2 with the appropriate control system and correctly wired EN/ISO 13849-1 || can reach SILCL 1 with the appropriate control system and correctly wired EN/IEC 62061 || can reach PL = c with the appropriate control system and correctly wired EN/ISO 13849-1