Schneider Electric

XPSMCMC10804B

1 / 1
thumbnail

Description

Active Mature
This Modicon MCM safety controller CPU is supplied with 24Vdc, has 8 safe digital inputs, 4 start/restart interlock inputs, 4 single channel OSSD, 4 test outputs, 4 configurable status outputs, fitted with captive screw clamp terminals. It embeds a Mini USB 2.0 connector to receive the configuration done with the software EcoStruxure Machine Expert - HVAC. It is an appropriate solution for machines with a small number of safety functions requiring the configuration flexibility of a safety controller. It can be used as standalone or with fourteen expansion modules. The system is expandable up to 128 inputs, 16 outputs and up to 32 diagnostic status outputs, ideal for machines requiring multiple safety function monitoring. This safety controller CPU figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, communication, master enable, restart signal, output channels). It is a CPU with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. It weighs 0.26kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The kit includes 1 x safety controller CPU and 1 x backplane expansion connector. The safety controller CPU instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Country of Origin
IT
Part Number
XPSMCMC10804B
Tariff Code
85371091
EAN
3606481987075
UNSPSC
32151707
Payment methods:
Best offer from:
GBTrusted Automa.Net Supplier
Availability:
1 pc.
In-Stock
Updated at: 21-10-2024
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
A total of 2 Parts In-Stock from 2 Distributors
Delivery from:
GB
GB
DE
DE
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (1)

XPSMCMC10804B product image
Schneider Electric

XPSMCMC10804B

Condition:
New Surplus
Available:
1 pc.
In-Stock
Updated at: 08-11-2024
Offer from:
DETrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
Offer with manufacturer lead time
Ships in:On Request
Best price:
€237.83

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1409010EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Free of Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc
Yes
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1409010EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
TÜV || RCM || cULus
Ambient Air Temperature For Operation
-10-55 °C
Standards
IEC 61496-1 || ISO 13849-1 || IEC 61508 || IEC 61800-5-1 || IEC 62061
Pollution Degree
2
Electromagnetic Compatibility
electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2 || electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2 || susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3 || susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3
Shock Resistance
10 gn 16 ms) 1000 shocks on each axis IEC 61496-1
Vibration Resistance
+/-0.35 mm 10-55 Hz)IEC 61496-1
[Uimp] Rated Impulse Withstand Voltage
4 kV IEC 61800-5-1
Ip Degree Of Protection
IP20
Relative Humidity
10-95 %
Ambient Air Temperature For Storage
-20-85 °C
Service Life
20 year(s)
Safety Reliability Data
PFHd = 1.35E-8 1/h high || DC > 99 % || MTTFd < 100 years
Overvoltage Category
II
Insulation
250 V AC between power supply and housing IEC 61800-5-1

Specifications

Discrete Output Type
PNP
Discrete Input Type
safety input || PNP
Range Of Product
Modicon Safety automation
Discrete Input Voltage
24 V
Number Of Outputs
4.0 safety outputs OSSD contactor/drive connection || 4.0 test line control outputs || 4.0 configurable diagnostic connection
Discrete Input Current
400 mA
Product Or Component Type
modular safety controller CPU kit
Number Of Inputs
8.0 digital input connection || 4.0 digital interlock start/restart or external device monitoring
[Us] Rated Supply Voltage
24 V - 20...20 % DC
Kit Composition
1 safety controller CPU || 1 backplane expansion connector
Electrical Connection
screw terminal
Discrete Output Current
400 mA
Function Of Module
emergency stop ISO 13850 || guard monitoring EN/ISO 14119 || enabling switch monitoring IEC 60947-5-1 || light curtain monitoring IEC 61496-1 || foot switch monitoring IEC 60947-5-1 || light curtain monitoring EN/ISO 14119 || switch monitoring EN 574 || two-hand control EN/ISO 14119 || safety mat monitoring IEC 61326-1 || switch monitoring IEC 61800-5-2 || muting function of light curtains IEC 61800-5-2 || safety time delays || counter functions
Device Short Name
XPSMCM

Complementary

Connections - Terminals
2 captive screw terminals, removable terminal block || 1 captive screw terminals, removable terminal block
Height
99 mm
Integrated Connection Type
backplane expansion bus || USB 2.0 port
Cable Cross Section
0.2-1.5 mm² - AWG 24...AWG 16 flexible without cable end || 0.2-2.5 mm² - AWG 24...AWG 14 flexible without cable end || 0.25-1 mm² - AWG 23...AWG 18 flexible with cable end, without bezel || 0.25-2.5 mm² - AWG 23...AWG 14 flexible with cable end, with bezel || 0.25-1.5 mm² - AWG 23...AWG 16 flexible with cable end, without bezel || 0.5-1.5 mm² - AWG 20...AWG 16 flexible with cable end, with double bezel || 0.2-1 mm² - AWG 24...AWG 18 solid without cable end || 0.2-2.5 mm² - AWG 24...AWG 14 solid without cable end
Local Signalling
1 LED green PWR power ON || 1 LED green RUN RUN (status) || 1 LED red E IN internal error || 1 LED red E EX external error || 1 LED orange COM communication || 1 LED blue EN master enable || 8 LEDs yellow IN input status || 2 LEDs green/red OUT output status || 2 LEDs yellow RST restart signal || 2 LEDs yellow STATUS output channel
Maximum Number Of I/O Expansion Module
14 128 input || 14 32.0 output
Net Weight
0.155 kg
Power Dissipation In W
3 W
Quality Labels
CE
Mounting Support
omega 35 mm DIN rail EN 50022
Load Capacitance
0.82 µF
Width
22.5 mm
Inductive Load
2.4 mH
Depth
114.5 mm
Synchronisation Time Between Inputs
< 0.5 ms
Data Storage Equipment
SD card optional)
Safety Level
can reach category 4 ISO 13849-1 || can reach PL = e ISO 13849-1 || type 4 IEC 61496-1 || SILCL 3 IEC 62061