module XPS-MP - 2 independent functions - 24 V DC
XPSMP11123P
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
$675.00
1
Payment methods:
A total of 11 Parts In-Stock from 10 Distributors
Offer with manufacturer lead time
Ships in:1 - 2 business days
Best price:
€225.44

Additional Information

Part Number
XPSMP11123P
UNSPSC
32151802
Tariff Code
8537109170
Country of Origin
ID

Specifications

Product Certifications
UL || BIA || CSA
Type Of Start
automatic or unmonitored 1) || monitored 15) || monitored 2) || monitored 4) || monitored 6) || monitored 8) || monitored 9) || automatic or unmonitored 10) || automatic or unmonitored 11) || automatic or unmonitored 14) || automatic or unmonitored 3) || automatic or unmonitored 5) || automatic or unmonitored 7) || monitored 12) || monitored 13)
[Us] Rated Supply Voltage
24 V DC - 20...20 %
Range Of Product
Preventa Safety automation
Standards
DIN V VDE 801 + A1 || EN/IEC 60204-1 || EN/IEC 60947-1 + A11 || EN/IEC 60947-5-1
Product Or Component Type
safety controller with pre-defined function
Safety Module Name
XPSMP
Connections - Terminals
captive screw clamp terminals, removable terminal block solid 0.2...1 mm² without cable end, 2 wires || captive screw clamp terminals, removable terminal block flexible 0.2...1.5 mm² without cable end, 2 wires || captive screw clamp terminals, removable terminal block flexible 0.2...2.5 mm² without cable end, 1 wire || captive screw clamp terminals, removable terminal block solid 0.2...2.5 mm² without cable end, 1 wire || captive screw clamp terminals, removable terminal block flexible 0.25...1 mm² with cable end, without bezel, 2 wires || captive screw clamp terminals, removable terminal block flexible 0.25...2.5 mm² with cable end, with bezel, 1 wire || captive screw clamp terminals, removable terminal block flexible 0.25...2.5 mm² with cable end, without bezel, 1 wire || captive screw clamp terminals, removable terminal block flexible 0.5...1.5 mm² with cable end, with double bezel, 2 wires
Safety Module Application
2 independent functions
Checks
configuration 10) || configuration 13) || configuration 3) || configuration 4) || configuration 5) || configuration 6) || configuration 9)
Safety Use Category
category 4 maximum EN/IEC 60954-1
Safety Level
can reach PL e/category 4 EN/ISO 13849-1 || can reach SIL 3 EN/IEC 62061

Contractual warranty

Warranty
18 months

Complementary

Height
99 mm
Mounting Support
35 mm symmetrical DIN rail
Output Thermal Current
2 A for 1 output and 4 A for the other 2 outputs relay || 3.3 A for all 3 outputs relay simultaneously || 6 A for 1 output and 2 A for the other 2 outputs relay
Power Consumption In W
5 W
Minimum Output Voltage
17 V relay output
Minimum Output Current
10 mA relay output
[Ith] Conventional Free Air Thermal Current
20 A
Associated Fuse Rating
4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 || 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
[Uimp] Rated Impulse Withstand Voltage
4 kV III EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
Net Weight
0.32 kg
Number Of Additional Circuits
3 solid state outputs
[Ui] Rated Insulation Voltage
300 V 2)EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
Local Signalling
12 LEDs
Maximum Line Resistance
100 Ohm <2000 m
Input Protection Type
internal, electronic
Width
45 mm
Number Of Safety Circuits
3 NO relays per function (6 NO total), volt-free
Depth
114 mm
Synchronisation Time Between Inputs
0.5 s 13) || unlimited 8) || 1.5 s 14) || 1.5 s 15) || 1.5 s 5) || 1.5 s 6) || 1.5 s 9) || unlimited 3) || unlimited 4) || unlimited 7)
[Uc] Control Circuit Voltage
24 V
Function Of Module
0 functions disabled (factory setting) || 3 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 || 4 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 || 5 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 || 6 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 || 7 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 || 8 emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 || 9 guard monitoring for injection presses and blowing machines, category 4 || 1 emergency stop monitoring 1-channel wiring, category 2 || 10 enabling grip switch monitoring (3-position switch), category 4 || 11 sensing mat and edges monitoring, category 3 || 12 sensing mat and edges monitoring, category 3 || 13 relay output safety light curtain monitoring, category 4 || 14 coded magnetic switch monitoring, category 4 || 15 coded magnetic switch monitoring, category 4 || 2 emergency stop monitoring 1-channel wiring, category 2
Breaking Capacity
20 mA 24 V static output circuit || 1.5 A 24 V DC-13)50 ms relay output
Maximum Response Time On Input Open
30 ms
Breaking Capacity
180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1406024EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1406024EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Ambient Air Temperature For Operation
-10-55 °C
Ip Degree Of Protection
IP20 terminals) || IP40 enclosure)
Ambient Air Temperature For Storage
-25-85 °C

Documents

Data Sheet

Download