1 / 2
thumbnail
thumbnail

Description

Active Mature
Country of Origin
ID
Part Number
XPSPVT1180
Tariff Code
85364190
EAN
3389110724837
UNSPSC
32151802
Payment methods:
Best offer from:
ITTrusted Automa.Net Supplier
Availability:
5 pcs.
In-Stock
Updated at: 21-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
A total of 8 Parts In-Stock from 2 Distributors
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (1)

XPSPVT1180 product image
Schneider Electric

XPSPVT1180

Condition:
New Surplus
Available:
3 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
GBTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
£751.37
net

Environment

Product Certifications
CSA || UL || TÜV
Ambient Air Temperature For Operation
-10-55 °C
Standards
IEC 693 || IEC 60204-1 || IEC 60947-5-1
Ip Degree Of Protection
IP20 terminals)IEC 60529 || IP40 enclosure)IEC 60529
Ambient Air Temperature For Storage
-25-85 °C

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1408008EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1408008EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Complementary

Height
73 mm
Mounting Support
35 mm symmetrical DIN rail
Power Consumption In W
6 W
Minimum Output Voltage
17 V relay output
Minimum Output Current
10 mA relay output
[Ith] Conventional Free Air Thermal Current
2.5 A
Associated Fuse Rating
4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum Output Wiping Time
100 ms
[Uimp] Rated Impulse Withstand Voltage
4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
Net Weight
0.54 kg
Connections - Terminals
captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² with cable end || captive screw clamp terminals, 2 x 2.5 mm² without cable end
[Ui] Rated Insulation Voltage
300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
Local Signalling
8 LEDs
Number Of Terminal Blocks
20
Enclosure Material
polycarbonate
Width
100 mm
Depth
118 mm
Breaking Capacity
1.5 A 24 V DC-13)50 ms relay output
Maximum Response Time On Input Open
15 ms
Breaking Capacity
180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output

Specifications

[Us] Rated Supply Voltage
24 V DC - 10...10 %
Range Of Product
Preventa Safety automation
Product Or Component Type
Preventa safety module
Enclosure Type
removable
Safety Module Name
XPSPVT
Output Type
relay, 2 NO + 1 NC, volt-free
Safety Module Application
for dynamic monitoring of hydraulic valves on linear presses
Safety Reliability Data
MTTFd = 50.9 years ISO 13849-1 || DC = 0...99 % ISO 13849-1 || PFHd = 2.24E-8 1/h IEC 62061
Function Of Module
monitoring hydraulic valves
Safety Level
can reach PL e/category 4 ISO 13849-1 || can reach SILCL 3 IEC 62061