Schneider Electric

XUBLAKCNM12T

1 / 1
thumbnail

Description

Active Mature
This photo-electric sensor is part of the XU Application range. It is recommended for material handling applications. This transmitter is a separate component for the thru-beam system sensors XUBLAPCNM12 or XUBLANCNM12, laser transmission. It features a plastic body, design 18, and an M12 connector. 3-wire DC.
Country of Origin
FR
Part Number
XUBLAKCNM12T
Tariff Code
85365080
EAN
3389119021043
UNSPSC
39121528
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Specifications

Series Name
Application material handling
Electrical Connection
1 male connector M12, 4 pins
Range Of Product
Telemecanique Photoelectric sensors XU
Emission
red laser thru beam class 1 670 nm IEC 60825-1
Detection System
thru beam
Sensor Design
cylindrical M18
Supply Circuit Type
DC
Electronic Sensor Type
photo-electric sensor transmitter
Sensor Name
XUB
[Sn] Nominal Sensing Distance
0-100 m thru beam need a receiver
Material
plastic
Wiring Technique
3-wire

Contractual warranty

Warranty
18 months

Complementary

Current Consumption
25 mA no-load
Switching Frequency
<= 1500 Hz
Maximum Delay Response
0.4 ms
Maximum Delay Recovery
0.4 ms
Diameter
18 mm
Maximum Delay First Up
80 ms
Status Led
1 LED green)supply on
Lens Material
PMMA
Supply Voltage Limits
10-30 V DC
Switching Capacity In Ma
<= 100 mA overload and short-circuit protection)
Maximum Voltage Drop
<1.5 V closed state)
Enclosure Material
PBT
Add On Input
test by emission breaking
Length
66 mm
Net Weight
0.04 kg
[Us] Rated Supply Voltage
12...24 V DC reverse polarity protection

Offer Sustainability

Circularity Profile
ENVEOLI111208EN
Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111230EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product Certifications
UL || CE || CSA
Ambient Air Temperature For Operation
-10-45 °C
Ambient Air Temperature For Storage
-40-70 °C
Ip Degree Of Protection
IP67 double insulation IEC 60529
Vibration Resistance
7 gn +/- 1.5 mm 10-55 Hz) IEC 60068-2-6
Shock Resistance
30 gn 11 ms) IEC 60068-2-27