- Product Certifications
- CSA || GOST || CCC || C-tick || UL || BT 2006/95/EC
- Ik Degree Of Protection
- IK03 IEC 50102
- Ambient Air Temperature For Operation
- -40-70 °C
- Electromagnetic Compatibility
- electrostatic discharge immunity test - test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2 || electrostatic discharge immunity test - test level: 4 kV (on contact (on metal parts)) conforming to IEC 61000-4-2 || susceptibility to electromagnetic fields - test level: 20 V/m (80...3000 MHz) conforming to IEC 61000-4-3 || susceptibility to electromagnetic fields - test level: 6 V/m (3000...6000 MHz, distance = 20 m) conforming to IEC 61000-4-3
- Shock Resistance
- 25 gn 6 ms) 6000 shocks IEC 60068-2-27 || 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
- Vibration Resistance
- 5 gn 11-500 Hz)IEC 60068-2-6 || +/- 10 mm 2-11 Hz)IEC 60068-2-6
- Ip Degree Of Protection
- IP30 IEC 60529 back face)
- Directives
- 1999/5/EC - R&TTE directive || 2004/108/EC - electromagnetic compatibility
- Ambient Air Temperature For Storage
- -40-70 °C
- Relative Humidity
- 95-95 % -40-70 °C without condensation
- Mechanical Durability
- 1000000 cycles