Wago
750-880/040-000
1 / 2
- Part Number
- 750-880/040-000
- Tariff Code
- 85371091990
- UPC
- 4050821460121
- ETIM
- Group Code : EG000024
- Group Description : PLC's
- Class Description : PLC CPU-module
- Class Code : EC000236
- Version : 7
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Environmental Requirements
- Ambient temperature (operation)
- -40 … +70 °C
- Ambient temperature (storage)
- -40 … +85 °C
- Protection type
- IP20
- Pollution degree
- 2 per IEC 61131-2
- Operating altitude
- Without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)
- Relative humidity (without condensation)
- 95 %
- Relative humidity (with condensation)
- Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
- Mounting position
- Horizontal (standing/lying); vertical
- Mounting type
- DIN-35 rail
- Vibration resistance
- Per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373
- Shock resistance
- Per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373
- EMC immunity to interference
- Per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26; EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994
- EMC emission of interference
- Per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
- Exposure to pollutants
- Per IEC 60068-2-42 and IEC 60068-2-43
- Fire load
- 2.471 MJ
- Permissible H2S contaminant concentration at a relative humidity 75 %
- 10 ppm
- Permissible SO2 contaminant concentration at a relative humidity 75 %
- 25 ppm
Connection Data
- Connection technology: communication/fieldbus
- EtherNet/IPTM: 2 x RJ-45; Modbus (TCP, UDP): 2 x RJ-45
- Connection technology: system supply
- 2 x CAGE CLAMP®
- Connection technology: field supply
- 4 x CAGE CLAMP®
- Connection type 1
- System/field supply
- Solid conductor
- 0.25 … 2.5 mm² / 24 … 14 AWG
- Fine-stranded conductor
- 0.25 … 2.5 mm² / 24 … 14 AWG
- Strip length
- 8 … 9 mm / 0.31 … 0.35 inches
- Connection technology: device configuration
- 1 x Male connector; 4-pole
Physical Data
- Width
- 61.5 mm / 2.421 inches
- Height
- 100 mm / 3.937 inches
- Depth
- 71.9 mm / 2.831 inches
- Depth from upper-edge of DIN-rail
- 64.7 mm / 2.547 inches
Technical Data
- Communication
- EtherNet/IPTM || Modbus (TCP, UDP) || ETHERNET
- ETHERNET protocols
- HTTP || BootP || DHCP || DNS || SNTP || FTP || SNMP
- Visualization
- Web-Visu
- CPU
- 32 bits
- Programming languages per IEC 61131-3
- Instruction List (IL) || Ladder Diagram (LD) || Function Block Diagram (FBD) || Continuous Function Chart (CFC) || Structured Text (ST) || Sequential Function Chart (SFC)
- Programming environment
- WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)
- Configuration options
- WAGO-I/O-CHECK || Web-Based Management
- Baud rate (communication/fieldbus 1)
- 10/100 Mbit/s
- Baud rate
- 10/100 Mbit/s
- Transmission medium (communication/fieldbus)
- Twisted pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length
- Transmission performance
- Class D per EN 50173
- Program memory
- 1024 KB
- Data memory
- 1024 KB
- Non-volatile software memory
- 32 KB
- Type of memory card
- SD and SDHC up to 32 GB (all guaranteed properties only valid with WAGO 758-879/000-001 Memory Card)
- Memory card slot
- Push-push mechanism; cover lid (sealable)
- Number of modules per node (max.)
- 64
- Input and output process image (fieldbus) max.
- 1020 words/1020 words
- Indicators
- LED (LINK/ACT) green: Network connection via ports 1 … 2; LED (MS, NS) red/green: Status of node, network; LED (I/O, USR) red/green/orange: Local data bus status, status programmable by user; LED (A, B) green: System power supply status, field supply
- Derating
- Total current for system supply: 1700 mA (ambient (operating) temperature < 60 °C; 1500 mA (ambient (operating) temperature: 60 … 70 °C); Derating (supply voltage): Ambient temperatures under laboratory conditions: (−25 … +30 %); for −40 … +55 °C: 24 V (−25 … +20 %); for +55 … +70 °C: 24 V (−25 … +10 %); Lower limit in all temperature ranges: −27.5 % (including 15 % residual ripple)
- Supply voltage (system)
- 24 VDC; via pluggable connector (CAGE CLAMP® connection); Derating must be observed!
- Input current (typ.) at nominal load (24 V)
- 500 mA
- Power supply efficiency (typ.) at nominal load (24 V)
- 90 %
- Current consumption (5 V system supply)
- 450 mA
- Total current (system supply)
- 1700 mA
- Supply voltage (field)
- 24 VDC; Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power jumper contacts; Derating must be observed!
- Current carrying capacity (power jumper contacts)
- 10 A
- Number of outgoing power jumper contacts
- 2
- Ratings per
- IEC/EN 60664-1
- Rated surge voltage
- 1 kV
Mechanical Data
- Weight
- 167.000 g
- Color
- Dark gray
- Housing material
- Polycarbonate; polyamide 6.6
- Conformity marking
- CE
Specifications
- Product Group Code
- 0015
Commercial Data
- Packaging type
- Box
- Country of origin
- DE
- GTIN
- 4050821460121
- Customs tariff number
- 85371091990