Ratings Per Iec/En

Ratings per
IEC/EN 60947-7-1
Nominal voltage (III/3)
1000 V
Rated impulse voltage (III/3)
8 kV
Rated current
192 A
Current at conductor cross-section (max.) mm²
232 A
Legend (ratings)
(III / 3) ≙ Overvoltage category III / Pollution degree 3

Environmental Requirements

Continuous operating temperature
-35 … +105 °C

Physical Data

Width
20.5 mm / 0.807 inches
Height
76.5 mm / 3.012 inches
Depth from upper-edge of DIN-rail
84 mm / 3.307 inches

Material Data

Note (material data)
Information on material specifications can be found here
Color
Gray
Insulation material
Polyamide (PA66)
Flammability class per UL94
V0
Fire load
0.000 MJ
Weight
141.000 g

Mechanical Data

Tightening torque
6 … 12 Nm
Mounting type
DIN-rail 35 x 7.5
Marking level
Side marking

Specifications

Product Group Code
0001

Commercial Data

Packaging type
Box
Country of origin
DE
GTIN
4055143940757
Customs tariff number
85369010000

Ratings Per Csa

Approvals per
CSA 22.2 No 158
Rated voltage CSA (Use Group B)
600 V
Rated current CSA (Use Group B)
205 A
Rated voltage CSA (Use Group C)
600 V
Rated current CSA (Use Group C)
205 A
Rated voltage CSA (Use Group D)
600 V
Rated current CSA (Use Group D)
205 A

Power Loss

Power loss, per pole (potential)
6.2669 W
Rated current IN for specified power loss
192 A
Resistance value for specified, current-dependent power loss
0.00017 Ω

Connection 1

Connection technology
Screw connection
Actuation type
T-wrench; 6 mm
Connectable conductor materials
Copper || Aluminum
Connectable conductor materials (note)
Terminating Aluminum Conductors Both restrictions and application notes must be observed when terminating aluminum conductors. These instructions can be found in the WAGO Webshop under “Downloads – Documentation – Additional Information: Terminating Aluminum Conductors.”
Nominal cross-section
70 mm²
Solid conductor
10 … 95 mm² / 8 … 3/0 AWG
Stranded conductor
10 … 95 mm² / 8 … 3/0 AWG
Fine-stranded conductor
10 … 70 mm² / 8 … 2/0 AWG
Fine-stranded conductor; with insulated ferrule
10 … 70 mm² / 8 … 2/0 AWG
Strip length
22 mm / 0.87 inches
Wiring direction
Side-entry wiring
Screw thread
M8

Ratings Per Ul 1059

Approvals per
UL 1059
Rated voltage UL (Use Group B)
600 V
Rated current UL (Use Group B)
205 A
Rated voltage UL (Use Group C)
600 V
Rated current UL (Use Group C)
205 A
Rated voltage UL (Use Group D)
600 V
Rated current UL (Use Group D)
205 A