Description
SAK Series, Fuse terminal, Rated cross-section: 4 mm², Screw connection, Direct mounting- Part Number
- 0105260000
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Approvals
- Approvals
- CE, EAC
- ROHS
- Conform
Display Element
- Operating voltage for display, max.
- 500 V
- Type of voltage for indicator
- DC
Dimensions And Weights
- Width
- 8.1 mm
- Width (inches)
- 0.319 inch
- Height
- 58 mm
- Height (inches)
- 2.283 inch
- Depth
- 43 mm
- Depth (inches)
- 1.693 inch
- Net weight
- 14.64 g
Fuse Terminals
- Cartridge fuse
- G-Si. 5 x 20
- Display
- Without LED
- Fuse holder (cartridge holder)
- Pivoting
- Operating voltage, max.
- 500 V
- Type of voltage for indicator
- DC
Additional Technical Data
- Explosion-tested version
- No
- Installation advice
- Direct mounting
- Number of similar terminals
- 1
- Open sides
- right
- Type of mounting
- Snap-on
Material Data
- Material
- PA 66
- Colour
- orange
- UL 94 flammability rating
- V-2
Safety Note
- Safety notice
- Safety Information
Classifications
- ETIM 6.0
- EC000899
- ETIM 7.0
- EC000899
- EClass 9.0
- 27-14-11-16
- EClass 9.1
- 27-14-11-16
- EClass 10.0
- 27-14-11-16
- UNSPSC
- 30-21-18-11
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
System Specifications
- Version
- Screw connection, Fuse cartridge, One end without connector
- End cover plate required
- Yes
- Number of potentials
- 1
- Number of levels
- 1
- Number of clamping points per level
- 2
- Number of potentials per tier
- 1
- Levels cross-connected internally
- No
- PE connection
- No
- Rail
- TS 35, TS 32
- N-function
- No
- PE function
- No
- PEN function
- No
Temperatures
- Storage temperature, max.
- 40 °C
- Storage temperature, min.
- 10 °C
- Storage temperature
- 10 °C...40 °C
- Continuous operating temp., min.
- -50 °C
- Continuous operating temp., max.
- 100 °C
Rating Data
- Rated cross-section
- 4 mm²
- Rated voltage
- 500 V
- Rated current
- 19 A
- Volume resistance according to IEC 60947-7-x
- 1 mΩ
- Power loss in accordance with IEC 60947-7-x
- 1.02 W
- Rated impulse withstand voltage
- 6 kV
- Pollution severity
- 3
Conductors For Clamping (Rated Connection)
- Blade size
- 0.6 x 3.5 mm
- Clamping range, max.
- 4 mm²
- Clamping range, min.
- 0.13 mm²
- Clamping screw
- M 3
- Connection cross-section, stranded, max.
- 4 mm²
- Connection cross-section, stranded, min.
- 1.5 mm²
- Connection direction
- on side
- Gauge to IEC 60947-1
- A3
- Number of connections
- 2
- Stripping length
- 9 mm
- Tightening torque, max.
- 1 Nm
- Tightening torque, min.
- 0.5 Nm
- Torque level with DMS electric screwdriver
- 2
- Twin wire-end ferrules, max.
- 1.5 mm²
- Twin wire-end ferrules, min.
- 0.5 mm²
- Type of connection
- Screw connection
- Wire connection cross section AWG, max.
- AWG 12
- Wire connection cross section AWG, min.
- AWG 26
- Wire connection cross section, finely stranded, max.
- 4 mm²
- Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.
- 4 mm²
- Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.
- 0.5 mm²
- Wire connection cross-section, finely stranded, min.
- 0.5 mm²
- Wire connection cross-section, solid core, max.
- 4 mm²
- Wire connection cross-section, solid core, min.
- 0.5 mm²
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther