Weidmuller

1059750015

1 / 2
thumbnail
thumbnail

Description

Dragline cable, PROFINET, M12 D-code – IP 67 angled pin, Open, Cat.5 (ISO/IEC 11801) / Cat.5e (TIA T568-B), PUR, 1.5 m
Part Number
1059750015
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Electrical Properties

Insulation strength
500,000 Ω

Cable Structure

Wire material
Stranded tin-plated copper wire
Standard designations
2YH(ST)C11Y 2x2x0,75/1,5-100 LI VZN GN FRNC
Strands
7
Cross-section
4*AWG 22/7 - 0.36 mm²
Insulation
PE
Insulation cross-section
1.5 mm
Wire core insulation thickness
0.38 mm
Number of wires
4
Arrangement of wire cores
Star-quad
Colour sequence or wires - wire pairs
white, yellow, blue, orange
Diameter of inner sheathing
3.9 mm
Filler
As central element
Shielding
SF/UTP
Complete shielding
Aluminium foil, Shielding braid made from copper wiring
Shielding braid thickness
0.13 mm
Overlap of shielding braid
85 %
Material sheath
PUR
Sheath diameter, min.
6.3 mm
Sheath diameter, max.
6.7 mm
Sheathing material thickness
0.9 mm
Sheathing colour
green (RAL 6018)

Approvals

Approvals
CULUS
ROHS
Conform
UL File Number Search
E316369

Mechanical And Material Properties Of Cable

Min. bending radius, once only
5 x cable diameter
Min. bending radius, repetitive
7.5 x cable diameter
Bending cycles
3 Mio
Pulling force
≤ 150 N
Speed
180 m/min
Acceleration
4 m/s²
Abrasion resistance
very good
Resistance to spread of flame
in accordance with IEC 60332-1
Resistance to oils
in accordance with IEC 60811-2-1
UV-resistant
Yes
Silicone-free
Yes
Halogen
halogen-free, according to IEC 60754-2
Fire propagation
No

Dimensions And Weights

Length
1.5 m
Length (inches)
0.059 inch
Net weight
116 g
Insulation cross-section
1.5 mm

Plug

Connector left
M12 D-code – IP 67 angled pin
Connector right
Open

Standards

Connector standard
IEC 61076-2-101
Standard, insulating material
DIN EN 50290-2-23 (VDE 0819) Table 2/A (HD 624.3)
Standard, wire material
DIN EN 13602 Cu-ETP-A
Standard, shielding material
DIN EN 13602 Cu-ETP-A..B
Certificate no. (cULus)
E316369

Classifications

ETIM 6.0
EC002599
ETIM 7.0
EC002599
EClass 9.0
27-06-03-08
EClass 9.1
27-06-03-08
EClass 10.0
27-06-03-08

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Electrical Properties Of Cable

Category
Cat.5 (ISO/IEC 11801) / Cat.5e (TIA T568-B)
Operating voltage (UL rating)
600 V undefined
Test voltage: wire-wire-shield
2000 Veff, 50 Hz, 1 min
Characteristic impedance
100 ± 15 Ω at 1–100 MHz
Loop resistance
120 Ω/km
Deviation
40 ns/100m
Resistance differential
3 %
Transfer impedance
20 mΩ/m at 10 MHz
Insulation strength
500,000 Ω
Capacity at 1 kHz
52 nF/km
Signal propagation time
5.3 ns/m
Speed
180 m/min

Temperatures

Operating temperature, max.
70 °C
Operating temperature, min.
-40 °C
Storage temperature, max.
70 °C
Storage temperature, min.
-50 °C
Operating temperature
-40 °C...70 °C
Storage temperature
-50 °C...70 °C
Installation temperature
-20 °C...60 °C