Weidmuller

1063260000

1 / 4
thumbnail
thumbnail
thumbnail
thumbnail

Description

PCB plug-in connector Orange release lever BHZ 5.00/02/90LH SN BK/OR BX
Part Number
1063260000
Payment methods:
Best offer from:
USTrusted Automa.Net Supplier
Availability:
3 pcs.
In-Stock
Updated at: 21-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Rated Data Acc. To Ul 1059

Institute (cURus)
cURus
Certificate No. (cURus)
E60693
Rated voltage (Use group B / UL 1059)
300 V
Rated voltage (Use group C / UL 1059)
50 V
Rated voltage (Use group D / UL 1059)
300 V
Rated current (Use group B / UL 1059)
10 A
Rated current (Use group C / UL 1059)
10 A
Rated current (Use group D / UL 1059)
10 A
Wire cross-section, AWG, min.
AWG 26
Wire cross-section, AWG, max.
AWG 12
Reference to approval values
Specifications are maximum values, details - see approval certificate.

Approvals

Approvals
cURus, EAC
ROHS
Conform
UL File Number Search
E60693

Dimensions And Weights

Length
14.6 mm
Length (inches)
0.575 inch
Width
12.4 mm
Width (inches)
0.488 inch
Height
29 mm
Height (inches)
1.142 inch
Net weight
5.14 g

Rated Data Acc. To Iec

Tested acc. to standard
IEC 60664-1, IEC 61984
Rated current, min. number of poles (Tu=20°C)
10 A
Rated current, min. number of poles (Tu=40°C)
9 A
Rated voltage for surge voltage class / pollution degree II/2
400 V
Rated voltage for surge voltage class / pollution degree III/2
320 V
Rated voltage for surge voltage class / pollution degree III/3
250 V
Rated impulse voltage for surge voltage class/ pollution degree II/2
4 kV
Rated impulse voltage for surge voltage class/ pollution degree III/2
4 kV
Rated impulse voltage for surge voltage class/ contamination degree III/3
4 kV
Clearance, min.
3 mm
Creepage distance, min.
3.2 mm

Material Data

Insulating material
PA 66 GV30
Colour
black
Colour of operational elements
orange
Colour chart (similar)
RAL 9011
Insulating material group
II
Comparative Tracking Index (CTI)
≥ 400
Insulation strength
≥ 108 Ω
UL 94 flammability rating
V-0
Contact material
CuSn
Contact surface
tinned
Storage temperature, min.
-40 °C
Storage temperature, max.
85 °C
Max. relative humidity during storage
80 %
Operating temperature, min.
0 °C
Operating temperature, max.
120 °C
Temperature range, installation, min.
-25 °C
Temperature range, installation, max.
120 °C

Classifications

ETIM 6.0
EC002638
ETIM 7.0
EC002638
EClass 9.0
27-44-03-09
EClass 9.1
27-44-03-09
EClass 10.0
27-44-03-09

System Specifications

Product family
OMNIMATE Housing - series CH20M
Type of connection
Field connection
Pitch in mm (P)
5 mm
Pitch in inches (P)
0.197 inch
Number of poles
2
L1 in mm
5 mm
L1 in inches
0.197 inch
Number of rows
1
Pin series quantity
1
Can be coded
Yes
Tightening torque for screw flange, min.
0.4 Nm
Tightening torque for screw flange, max.
0.6 Nm
Plugging cycles
25

Notes

IPC conformity
Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request.

Conductors Suitable For Connection

Clamping range, min.
0.13 mm²
Clamping range, max.
3.31 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Solid, min. H05(07) V-U
0.2 mm²
Solid, max. H05(07) V-U
2.5 mm²
Stranded, max. H07V-R
2 mm²
Flexible, min. H05(07) V-K
0.2 mm²
W. plastic collar ferrule, DIN 46228 pt 4, min.
0.25 mm²
W. plastic collar ferrule, DIN 46228 pt 4, max.
2.5 mm²
W. wire end ferrule, DIN 46228 pt 1, min.
0.25 mm²
W. wire end ferrule, DIN 46228 pt 1, max.
2.5 mm²
Plug gauge in accordance with EN 60999 a x b; ø
2.8 mm x 2.4 mm; 3.0 mm
Reference text
The outside diameter of the plastic collar should not be larger than the pitch (P).
Max. clamping range
3.31 mm²

Rated Data Acc. To Csa

Rated voltage (Use group B / CSA)
300 V
Rated voltage (Use group C / CSA)
50 V
Rated voltage (Use group D / CSA)
300 V
Rated current (Use group B / CSA)
10 A
Rated current (Use group C / CSA)
10 A
Rated current (Use group D / CSA)
10 A
Wire cross-section, AWG, min.
AWG 26
Wire cross-section, AWG, max.
AWG 12