Weidmuller

1064700000

1 / 3
thumbnail
thumbnail
thumbnail

Description

Surge protection for instrumentation and control, 110 V, 156 V, 12 A, IEC 61643-21
Part Number
1064700000
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Further Details Of Approvals

GOST certificate
GOST-Zertifikat

General Data

Colour
black
Design
Terminal
Isolating function
No
Optical function display
No
Protection degree
IP20
Rail
TS 35
Segment
Measurement - Monitoring - Setting
UL 94 flammability rating
V-0
Version
Surge protection for measurement and control

Probability Of Failure

Λges
10
MTTF
11,416 years
PFH in 1*10
0
SFF
100 %
SIL PAPER
SIL Paper
SIL in compliance with IEC 61508
3

Approvals

Approvals
CE, CSAEX, EAC, FUSAFETY
ROHS
Conform

Insulation Coordination Acc. To En 50178

Pollution severity
2
Surge voltage category
III

Rated Data Iec / En

Capacitance
2.5 nF
Discharge current I
5 kA
Lightning test current I
2.5 kA
Lightning test current, I
1 kA
Max. continuous voltage, Uc (AC)
138 V
Max. continuous voltage, Uc (DC)
195 V
Number of poles
1
Overload - failure mode
Modus 2
Protection level U
< 1000 V
Rated current I
12 A
Rated voltage (AC)
110 V
Rated voltage (DC)
156 V
Requirements category acc. to IEC 61643-21
C2, C3, D1
Standards
IEC 61643-21
Surge current-carrying capacity C2
5 kA 8/20 μs
Surge current-carrying capacity C3
100 A 10/1000 μs
Surge current-carrying capacity D1
2.5 kA 10/350 μs
Voltage type
AC/DC
Volume resistance
< 0.1 Ω

Dimensions And Weights

Width
12.4 mm
Width (inches)
0.488 inch
Height
88.5 mm
Height (inches)
3.484 inch
Depth
81 mm
Depth (inches)
3.189 inch
Net weight
52.8 g

Csa Protection Data

Gas group C
IIB
Gas group D
IIA
Gas groups A, B
IIC
Input current, max. I
12 A
Input voltage, max. U
195 V
Internal capacity, max. C
0 nF
Internal inductance, max. L
0 µH

Connection Data

Type of connection
Screw connection
Tightening torque, min.
0.5 Nm
Tightening torque, max.
0.8 Nm
Clamping range, min.
0.5 mm²
Clamping range, max.
4 mm²
Wire cross-section, solid, min.
0.5 mm²
Wire cross-section, solid, max.
6 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), min.
0.5 mm²
Conductor cross-section, flexible, AEH (DIN 46228-1), max.
4 mm²
Connection cross-section, stranded, min.
0.5 mm²
Connection cross-section, stranded, max.
4 mm²

Rated Data Ul

UL certificate
UL Zertifikat

Tender Specification Sheets

Long specification
Feed-through terminal, 12.4mm wide with sparkover gap between the two signal lines and the mounting rail potential, TS 35 contact base.A signal with max. 12A can be protected here. When the terminal is fitted, a simultaneous electrically conducting contact is made between the mounting rail (earth) and the reference potential (ground) of the protection circuit in the terminal. Optical identification of the terminal based on the type of protected switching and the voltage level. The terminal can be labelled or marked.
Short specification
Feed-through terminal with sparkover gaps (GDT) between two signal lines and the mounting rail potential, TS 35 contact base. Version: 110 V UC 20kA

Classifications

ETIM 6.0
EC000943
ETIM 7.0
EC000943
EClass 9.0
27-13-08-07
EClass 9.1
27-13-08-07
EClass 10.0
27-13-08-07
UNSPSC
30-21-18-11

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Temperatures

Humidity
5...96 %
Operating temperature, max.
70 °C
Operating temperature, min.
-40 °C
Storage temperature, max.
80 °C
Storage temperature, min.
-40 °C
Operating temperature
-40 °C...70 °C
Storage temperature
-40 °C...80 °C

Ratings Iecex/Atex/Cul

CUL certificate
cUL Certificate