Weidmuller

1344680000

1 / 2
thumbnail
thumbnail

Description

System cable, Cat.7 (ISO/IEC 11801), LSZH, 305 m
Part Number
1344680000
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Cable Structure

Copper diameter
0.43 mm
Strands
7
Cross-section
4*2*AWG 27/7 - 4*2*0.1 mm²
Insulation
PE
Insulation cross-section
1.04 mm
Number of wires
8
Arrangement of wire cores
Twisted pair
Colour sequence or wires - wire pairs
white - blue, white - orange, white - green, white - brown
Shielding
S/FTP
Complete shielding
Shielding braid made from copper wiring
Overlap of shielding braid
60 %
Material sheath
LSZH
Sheath diameter, min.
5.5 mm
Sheath diameter, max.
5.9 mm
Sheathing colour
green

Approvals

Approvals
CULUS
ROHS
Conform
UL File Number Search
E349758

Mechanical And Material Properties Of Cable

Min. bending radius, once only
25 mm
Min. bending radius, repetitive
50 mm
Resistance to spread of flame
in accordance with IEC 60332-1
Halogen
No

Dimensions And Weights

Length
305 m
Length (inches)
12.008 inch
Net weight
12,180 g
Insulation cross-section
1.04 mm

Standards

Generic communication cable facilities
ISO / IEC 11801:2002, EN 50173-1:2007
Certificate no. (cULus)
E349758

Classifications

ETIM 6.0
EC000830
ETIM 7.0
EC003249
EClass 9.0
27-06-18-05
EClass 9.1
27-06-90-90
EClass 10.0
27-06-18-01

Electrical Properties Of Cable

Category
Cat.7 (ISO/IEC 11801)
Test voltage: wire-wire-shield
750 V DC, 1 min
Characteristic impedance
100 ± 15 Ω at 1–100 MHz
Loop resistance
183 Ω/km
Deviation
25 ns/100m
Resistance differential
5 %
Capacity at 1 kHz
46 nF/km

Temperatures

Operating temperature, max.
60 °C
Operating temperature, min.
-20 °C
Operating temperature
-20 °C...60 °C
Installation temperature
0 °C...50 °C