Weidmuller
1990970000
1 / 4
Description
TERMSERIES, solid-state relais, 1 NO contact (MOS-FET), Rated control voltage: 24…230 V UC ±10 % , Rated switching voltage: 3...33 V DC, Continuous current: 5 A, Screw connection- Part Number
- 1990970000
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 2 pcs.In-StockUpdated at: 21-11-2024
- Warranty:
- 12 months
- Estimated Delivery:
- On Request
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
General Data
- Rail
- TS 35
- Colour
- black
- UL 94 flammability rating
- V-0
Probability Of Failure
- MTTF
- 773 Years
Load Side
- Rated switching voltage
- 3...33 V DC
- Continuous current
- 5 A
- Rated switching current
- 5 A
- Switch-on delay
- ≤ 10 ms
- Switch-off delay
- < 100 ms
- Voltage drop at max. load
- ≤ 0.3 V
- Leakage current
- < 10 µA
- Min. switching current
- 1 mA
- Short-circuit-proof
- No
- Protective circuit, load side
- Free-wheeling diode
- Max. switching frequency (AC control voltage)
- 3 Hz
- Max. switching frequency (DC control voltage)
- 3 Hz
Approvals
- Approvals
- CE, CULUS, DNV GL, EAC
- ROHS
- Conform
- UL File Number Search
- E141197
Dimensions And Weights
- Width
- 12.8 mm
- Width (inches)
- 0.504 inch
- Height
- 89.6 mm
- Height (inches)
- 3.528 inch
- Depth
- 87.8 mm
- Depth (inches)
- 3.457 inch
- Net weight
- 60 g
Connection Data
- Wire connection method
- Screw connection
- Stripping length, rated connection
- 8 mm
- Tightening torque, max.
- 0.4 Nm
- Clamping range, rated connection
- 1.5 mm²
- Clamping range, min.
- 0.14 mm²
- Clamping range, max.
- 2.5 mm²
- Wire connection cross section AWG, min.
- AWG 26
- Wire connection cross section AWG, max.
- AWG 14
- Wire cross-section, solid, min.
- 0.14 mm²
- Wire cross-section, solid, max.
- 2.5 mm²
- Wire connection cross-section, finely stranded, min.
- 0.14 mm²
- Wire connection cross section, finely stranded, max.
- 2.5 mm²
- Wire cross-section, finely stranded, min. (AWG)
- AWG 26
- Wire cross-section, finely stranded, max. (AWG)
- AWG 14
- Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
- 0.25 mm²
- Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
- 2.5 mm²
- Conductor cross-section, flexible, AEH (DIN 46228-1), min.
- 0.25 mm²
- Conductor cross-section, flexible, AEH (DIN 46228-1), max.
- 2.5 mm²
- Wire connection cross section, finely stranded, two clampable wires, min.
- 0.5 mm²
- Wire cross-section, finely stranded, two clampable wires, max.
- 1 mm²
- Twin wire-end ferrules, min.
- 0.5 mm²
- Twin wire-end ferrules, max.
- 1 mm²
- Blade size
- size PH0
- Gauge to IEC 60947-1
- A1, B1
Rated Data Ul
- Ambient temperature (operational), max.
- 40 °C
- Connection cross-section AWG, min.
- AWG 26
- Connection cross-section AWG, max.
- AWG 14
- Type of conductor
- rigid copper conductor, flexible copper conductor
- Tightening torque, max.
- 0.4 Nm
- Pollution severity level
- 2
Contact Data
- Contact type
- 1 NO contact (MOS-FET)
Control Side
- Rated control voltage
- 24…230 V UC ±10 %
- Nominal control current
- 22.4 mA DC @ 24 V DC, 22.6 mA AC @ 24 V AC, 2.4 mA DC @ 230 V DC, 4.6 mA AC @ 230 V AC
- Power rating
- 540 mW @ 24 V DC, 545 mVA @ 24 V AC, 550 mW @ 230 V DC, 1.1 VA @ 230 V AC
- Cut-in / dropout voltage
- 12 V / 6 V AC12 V / 5 V DC
- Status indicator
- Green LED
- Protective circuit
- Rectifier
- Coil voltage of the replacement relay deviating from the rated control voltage
- Yes
- Coil voltage of the replacement relay
- 24 V DC
Classifications
- ETIM 6.0
- EC001504
- ETIM 7.0
- EC001504
- EClass 9.0
- 27-37-16-04
- EClass 9.1
- 27-37-16-04
- EClass 10.0
- 27-37-16-04
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Insulation Coordination
- Rated voltage
- 300 V
- Pollution severity
- 2
- Surge voltage category
- III
- Clearance and creepage distances for control side - load side
- ≥ 5.5 mm
- Dielectric strength for control side - load side
- 2.5 kVeff
- Dielectric strength to mounting rail
- 4 kVeff / 1 Min.
- Impulse withstand voltage
- 6 kV (1.2/50 µs)
- Protection degree
- IP20
Temperatures
- Humidity
- 5-95% relative humidity, Tu = 40°C, without condensation
- Operating temperature, max.
- 40 °C
- Operating temperature, min.
- -20 °C
- Storage temperature, max.
- 70 °C
- Storage temperature, min.
- -40 °C
- Operating temperature
- -20 °C...40 °C
- Storage temperature
- -40 °C...70 °C
Ratings Iecex/Atex/Cul
- Certificate no. (cULus)
- E141197
Further Details Of Approvals / Standards
- Standards
- DIN EN 50178
- Certificate no. (cULus)
- E141197
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther