Weidmuller
2014140000
1 / 4
Description
Printed circuit board terminals, 10.16 mm, Number of poles: 5, 90°, Solder pin length (l): 5 mm, tinned, black, Clamping yoke connection, Clamping range, max. : 16 mm², Box- Part Number
- 2014140000
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Rated Data Acc. To Ul 1059
- Institute (cURus)
- cURus
- Certificate No. (cURus)
- E60693
- Rated voltage (Use group B / UL 1059)
- 300 V
- Rated voltage (Use group C / UL 1059)
- 300 V
- Rated voltage (Use group D / UL 1059)
- 600 V
- Rated current (Use group B / UL 1059)
- 58 A
- Rated current (Use group C / UL 1059)
- 58 A
- Rated current (Use group D / UL 1059)
- 5 A
- Wire cross-section, AWG, min.
- AWG 26
- Wire cross-section, AWG, max.
- AWG 6
- Reference to approval values
- Specifications are maximum values, details - see approval certificate.
Approvals
- Approvals
- CSA, cURus
- ROHS
- Conform
- UL File Number Search
- E60693
Dimensions And Weights
- Width
- 51.6 mm
- Width (inches)
- 2.031 inch
- Height
- 36.5 mm
- Height (inches)
- 1.437 inch
- Height of lowest version
- 31.5 mm
- Depth
- 25.1 mm
- Depth (inches)
- 0.988 inch
- Net weight
- 46.6 g
Rated Data Acc. To Iec
- Tested acc. to standard
- IEC 60664-1, IEC 61984
- Rated current, min. number of poles (Tu=20°C)
- 76 A
- Rated current, max. number of poles (Tu=20°C)
- 72 A
- Rated current, min. number of poles (Tu=40°C)
- 72 A
- Rated current, max. number of poles (Tu=40°C)
- 62 A
- Rated voltage for surge voltage class / pollution degree II/2
- 1,000 V
- Rated voltage for surge voltage class / pollution degree III/2
- 1,000 V
- Rated voltage for surge voltage class / pollution degree III/3
- 800 V
- Rated impulse voltage for surge voltage class/ pollution degree II/2
- 6 kV
- Rated impulse voltage for surge voltage class/ pollution degree III/2
- 8 kV
- Rated impulse voltage for surge voltage class/ contamination degree III/3
- 8 kV
- Short-time withstand current resistance
- 1 x 1s with 700 A
Material Data
- Insulating material
- Wemid (PA)
- Colour
- black
- Colour chart (similar)
- RAL 9011
- Insulating material group
- I
- Comparative Tracking Index (CTI)
- ≥ 600
- UL 94 flammability rating
- V-0
- Contact material
- E-Cu
- Contact surface
- tinned
- Layer structure of solder connection
- 1.5-3 µm Ni / 4-6 µm Sn matt
- Storage temperature, min.
- -25 °C
- Storage temperature, max.
- 55 °C
- Max. relative humidity during storage
- 80 %
- Operating temperature, min.
- -50 °C
- Operating temperature, max.
- 120 °C
- Temperature range, installation, min.
- -25 °C
- Temperature range, installation, max.
- 120 °C
Classifications
- ETIM 6.0
- EC002643
- ETIM 7.0
- EC002643
- EClass 9.0
- 27-44-04-01
- EClass 9.1
- 27-44-04-01
- EClass 10.0
- 27-44-04-01
System Parameters
- Product family
- OMNIMATE Power - series LUP
- Wire connection method
- Clamping yoke connection
- Mounting onto the PCB
- THT solder connection
- Conductor outlet direction
- 90°
- Pitch in mm (P)
- 10.16 mm
- Pitch in inches (P)
- 0.4 inch
- Number of poles
- 5
- Fitted by customer
- Yes
- Number of rows
- 1
- Max. adjacent poles per row
- 12
- Solder pin length (l)
- 5 mm
- Solder pin dimensions
- 1.2 x 1.2 mm
- Solder eyelet hole diameter (D)
- 1.6 mm
- Solder eyelet hole diameter tolerance (D)
- + 0,1 mm
- Number of solder pins per pole
- 2
- Screwdriver blade
- 1.0 x 5.5, PZ 2
- Screwdriver blade standard
- DIN 5264
- Tightening torque, min.
- 1.2 Nm
- Tightening torque, max.
- 1.5 Nm
- Clamping screw
- M 4
- Stripping length
- 12 mm
- L1 in mm
- 40.64 mm
- L1 in inches
- 1.6 inch
- Touch-safe protection acc. to DIN VDE 0470
- IP20 plugged/ IP10 unplugged
- Touch-safe protection acc. to DIN VDE 57 106
- Safe from finger touch
- Volume resistance
- 0.50 mΩ
Packing
- Packaging
- Box
- VPE length
- 0 m
- VPE width
- 0 m
- VPE height
- 0 m
Notes
- Notes
- Additional colours on request Rated current related to rated cross-section & min. No. of poles. Wire end ferrule without plastic collar to DIN 46228/1 Wire end ferrule with plastic collar to DIN 46228/4 The data given under CSA relates to a cUL approval - E60693 P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. The test point can only be used as potential-pickup point.
- IPC conformity
- Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request.
Conductors Suitable For Connection
- Clamping range, min.
- 0.13 mm²
- Clamping range, max.
- 16 mm²
- Wire connection cross section AWG, min.
- AWG 22
- Wire connection cross section AWG, max.
- AWG 6
- Solid, min. H05(07) V-U
- 0.5 mm²
- Solid, max. H05(07) V-U
- 16 mm²
- Stranded, min. H07V-R
- 6 mm²
- Stranded, max. H07V-R
- 16 mm²
- Flexible, min. H05(07) V-K
- 0.5 mm²
- Flexible, max. H05(07) V-K
- 16 mm²
- W. plastic collar ferrule, DIN 46228 pt 4, min.
- 2.5 mm²
- W. plastic collar ferrule, DIN 46228 pt 4, max.
- 10 mm²
- W. wire end ferrule, DIN 46228 pt 1, min.
- 2.5 mm²
- W. wire end ferrule, DIN 46228 pt 1, max.
- 10 mm²
- Plug gauge in accordance with EN 60999 a x b; ø
- 5.4 mm x 5.1 mm; 5.3 mm
- Max. clamping range
- 16 mm²
Rated Data Acc. To Csa
- Institute (CSA)
- CSA
- Certificate No. (CSA)
- 200039-1198743
- Rated voltage (Use group B / CSA)
- 300 V
- Rated voltage (Use group C / CSA)
- 300 V
- Rated voltage (Use group D / CSA)
- 600 V
- Rated current (Use group B / CSA)
- 58 A
- Rated current (Use group C / CSA)
- 58 A
- Rated current (Use group D / CSA)
- 5 A
- Wire cross-section, AWG, min.
- AWG 22
- Wire cross-section, AWG, max.
- AWG 6
- Reference to approval values
- Specifications are maximum values, details - see approval certificate.
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther