EX signal isolating converter, Ex-input: I,ϑ, Safe-output: 4-20mA, 1-channel
Part Number
2456180000
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Probability Of Failure

SIL PAPER
SIL certificate

Approvals

Approvals
DNV GL, EAC
ROHS
Conform

Dimensions And Weights

Width
22.5 mm
Width (inches)
0.886 inch
Height
127.3 mm
Height (inches)
5.012 inch
Depth
114.6 mm
Depth (inches)
4.512 inch
Net weight
178 g

Safety-Related Specifications Low Demand Mode

Average Probability of Failure on Demand (PFD
3.96 x 10-4 (Tproof = 1 year), 6.5 x 10-4 (Tproof = 2 years), 1.41 x 10-4 (Tproof = 5 years)

Connection Data

Type of connection
PUSH IN
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 14
Wire cross-section, solid, min.
0.2 mm²
Wire cross-section, solid, max.
2.5 mm²
Wire connection cross-section, finely stranded, min.
0.2 mm²
Wire connection cross section, finely stranded, max.
2.5 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.
0.2 mm²
Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.
2.5 mm²

Rated Data Ul

UL certificate
E337701.pdf

Safety-Related Basic Specifications

Demand mode
High
Demand rate
3,000 s
Demand response time
Signal input: < 0.5 s (opto output), Temperature input: < 1.1 s (opto output)
Description of the "safe state"
analogue Output ≤ 3.6 mA or output ≥ 21 mA
Device type
B
Diagnostic test interval
30 s
Hardware fault tolerance (HFT)
0
Mean Time To Repair (MTTR)
24 h
Safe Failure Fraction (SFF)
90 %
T
3 Years
Total failure rate for dangerous detected failures (λ
367 FIT
Total failure rate for dangerous undetected failures (λ
61 FIT
Total failure rate for safe detected failures (λ
0 FIT
Total failure rate for safe undetected failures (λ
234 FIT
Safety category
SIL 2
Probability of outage PFH
6.1 x 10-8 h-1

Alarm Output

Alarm function
Line interruption at the input, Short circuit at input, No supply voltage, Device error
Type
Relay, 1 NC (voltage-free)
Nominal switching voltage
≤ 125 V AC / 110 V DC (safe area)≤ 32 V AC / 32 V DC (zone 2)
Continuous current
≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2)
Power rating
≤ 62.5 VA / 32 W (safe area)≤ 16 VA / 32 W (Zone 2)

Classifications

ETIM 6.0
EC002919
ETIM 7.0
EC002919
EClass 9.0
27-21-01-29
EClass 9.1
27-21-01-29
EClass 10.0
27-21-01-29

Output

Type
active (as current source) or passive (as current sink)
Influence of load resistance
≤ 0.01% of span / 100 Ω
Output signal limit
3.8…20.5 mA / 0…20.5 mA (dependent on range)
Output current
0…23 mA, configurable: 0…20 / 4…20 / 20…0 / 20…4 mA, configurable downscale (3.5 mA) ⁄ upscale (23 mA) @ error
Load impedance current
≤ 600 Ω

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Data For Ex Applications (Atex)

Voltage U
8.7 V DC
Current I
18.4 mA
Power P
40 mW
Marking
II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
Installation location
Device installed in safe area, zone 2

Insulation Coordination

EMC standards
DIN EN 61326, NE 21
Insulation voltage
2.6 kV (input / output)
Rated voltage
300 V

Input Ex

Input current
0...20 mA, 4…20mA
Input resistance, current
20 Ω + PTC 50 Ω
Line resistance in measuring circuit
≤ 50 Ω
Sensor
RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Thermocouples: B, E, J, K, N, R, S, T ; in compliance with IEC 60584-1 and L, U in compliance with DIN43710
Temperature input range
Configurable
Type
intrinsically safe circuit, RTD, TC, DC (mA)

Temperatures

Humidity
0...95 % (no condensation)
Operating temperature, max.
60 °C
Operating temperature, min.
-20 °C
Storage temperature, max.
85 °C
Storage temperature, min.
-20 °C
Operating temperature
-20 °C...60 °C
Storage temperature
-20 °C...85 °C

Ratings Iecex/Atex/Cul

ATEX certificate
10ATEX0020X.pdf
IEC Ex certificate
IECEx certification

General Specifications

Configuration
With FDT/DTM software
Voltage supply
19.2…31.2 V DC
Type of connection
PUSH IN
Power consumption
≤ 0.8 W
Step response time
≤ 400 ms (with current), ≤ 1 s (with temperature)
Protection degree
IP20
Humidity
0...95 % (no condensation)