Description
Surge protection for instrumentation and control, 5 V, 450 mA, IEC 61643-21, HART-compatible- Part Number
- 8924430000
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 3 pcs.In-StockUpdated at: 30-04-2024
- Estimated Delivery:
- On Request
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Further Details Of Approvals
- GOST certificate
- GOST-Zertifikat
General Data
- Colour
- orange
- Design
- Terminal, miscellaneous
- Optical function display
- No
- Protection degree
- IP20
- Segment
- Measurement - Monitoring - Setting
- UL 94 flammability rating
- V-0
- Version
- without warning function / function indicator
- Protected current loops
- 2
Probability Of Failure
- Λges
- 45
- MTTF
- 2,537 Years
- PFH in 1*10
- 2.95
- SFF
- 93.98 %
- SIL PAPER
- SIL Paper
- SIL in compliance with IEC 61508
- 3
Approvals
- Approvals
- CE, CSAEX, EAC, FUSAFETY, OEVE, UL
- ROHS
- Conform
- UL File Number Search
- E311081
Insulation Coordination Acc. To En 50178
- Pollution severity
- 2
- Surge voltage category
- III
Rated Data Iec / En
- Discharge current I
- 2.5 kA
- Fuse
- 0.5 A
- Lightning test current, I
- 2.5 kA
- Max. continuous voltage, Uc (DC)
- 6.4 V
- Number of poles
- 1
- Overload - failure mode
- Modus 2
- Protection level U
- < 800 V
- Protection level on output side Wire-PE 1kV/µs, typically
- 450 V
- Protection level on output side Wire-wire 1 kV/µs, typically
- 12 V
- Protection level on output side Wire-wire 8/20 µs, typically
- 12 V
- Protection level, U
- 12 V
- Pulse-reset capacity
- ≤ 20 ms
- Rated current I
- 450 mA
- Rated voltage (DC)
- 5 V
- Requirements category acc. to IEC 61643-21
- C1, C2, C3, D1
- Signal transmission properties (-3 dB)
- 103 MHz
- Signalling contact
- No
- Standards
- IEC 61643-21, HART-compatible
- Surge current-carrying capacity C1
- < 1 kA 8/20 μs
- Surge current-carrying capacity C2
- 5 kA 8/20 μs
- Surge current-carrying capacity C3
- 100 A 10/1000 μs
- Surge current-carrying capacity D1
- 2.5 kA 10/350 μs
- Voltage type
- DC
- Volume resistance
- 2.20 Ω
Dimensions And Weights
- Width
- 17.8 mm
- Width (inches)
- 0.701 inch
- Height
- 90 mm
- Height (inches)
- 3.543 inch
- Depth
- 69 mm
- Depth (inches)
- 2.717 inch
- Net weight
- 46 g
Csa Protection Data
- Gas group C
- IIB
- Gas group D
- IIA
- Gas groups A, B
- IIC
- Input voltage, max. U
- 6.4 V
- Internal capacity, max. C
- 10 nF
- Internal inductance, max. L
- 0 µH
Rated Data Ul
- Certificate No. (UL)
- E311081
- UL certificate
- UL 497b Certificate
Tender Specification Sheets
- Long specification
- Surge protection plug for use in connection with the base element VSPC BASE 2CL for two floating-ground driven paired cables, for IT use. Two-stage protection circuit consisting of coarse protection, decoupling resistors and fine protection between the signal wires and coarse common mode voltage protection to earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Optical identification of the protected plug based on the type of protected switching and the voltage level. Protected plug with coding pin and counter-profile for the base element. It is possible to mark the plug.
- Short specification
- Surge protection plug for use in connection with the base element VSPC BASE 2CL for two floating-ground driven paired cables, for IT use, 5 V DC.
Classifications
- ETIM 6.0
- EC000943
- ETIM 7.0
- EC000943
- EClass 9.0
- 27-13-08-07
- EClass 9.1
- 27-13-08-07
- EClass 10.0
- 27-13-08-07
- UNSPSC
- 30-21-19-21
Environmental Product Compliance
- REACH SVHC
- Lead 7439-92-1
Temperatures
- Humidity
- 5...96 %
- Operating temperature, max.
- 70 °C
- Operating temperature, min.
- -40 °C
- Storage temperature, max.
- 80 °C
- Storage temperature, min.
- -40 °C
- Operating temperature
- -40 °C...70 °C
- Storage temperature
- -40 °C...80 °C
Ratings Iecex/Atex/Cul
- CUL certificate
- cUL Certificate
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther