Weidmuller

8924430000

1 / 5
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail

Description

Surge protection for instrumentation and control, 5 V, 450 mA, IEC 61643-21, HART-compatible
Part Number
8924430000
Payment methods:
Best offer from:
GBTrusted Automa.Net Supplier
Availability:
3 pcs.
In-Stock
Updated at: 30-04-2024
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Further Details Of Approvals

GOST certificate
GOST-Zertifikat

General Data

Colour
orange
Design
Terminal, miscellaneous
Optical function display
No
Protection degree
IP20
Segment
Measurement - Monitoring - Setting
UL 94 flammability rating
V-0
Version
without warning function / function indicator
Protected current loops
2

Probability Of Failure

Λges
45
MTTF
2,537 Years
PFH in 1*10
2.95
SFF
93.98 %
SIL PAPER
SIL Paper
SIL in compliance with IEC 61508
3

Approvals

Approvals
CE, CSAEX, EAC, FUSAFETY, OEVE, UL
ROHS
Conform
UL File Number Search
E311081

Insulation Coordination Acc. To En 50178

Pollution severity
2
Surge voltage category
III

Rated Data Iec / En

Discharge current I
2.5 kA
Fuse
0.5 A
Lightning test current, I
2.5 kA
Max. continuous voltage, Uc (DC)
6.4 V
Number of poles
1
Overload - failure mode
Modus 2
Protection level U
< 800 V
Protection level on output side Wire-PE 1kV/µs, typically
450 V
Protection level on output side Wire-wire 1 kV/µs, typically
12 V
Protection level on output side Wire-wire 8/20 µs, typically
12 V
Protection level, U
12 V
Pulse-reset capacity
≤ 20 ms
Rated current I
450 mA
Rated voltage (DC)
5 V
Requirements category acc. to IEC 61643-21
C1, C2, C3, D1
Signal transmission properties (-3 dB)
103 MHz
Signalling contact
No
Standards
IEC 61643-21, HART-compatible
Surge current-carrying capacity C1
< 1 kA 8/20 μs
Surge current-carrying capacity C2
5 kA 8/20 μs
Surge current-carrying capacity C3
100 A 10/1000 μs
Surge current-carrying capacity D1
2.5 kA 10/350 μs
Voltage type
DC
Volume resistance
2.20 Ω

Dimensions And Weights

Width
17.8 mm
Width (inches)
0.701 inch
Height
90 mm
Height (inches)
3.543 inch
Depth
69 mm
Depth (inches)
2.717 inch
Net weight
46 g

Csa Protection Data

Gas group C
IIB
Gas group D
IIA
Gas groups A, B
IIC
Input voltage, max. U
6.4 V
Internal capacity, max. C
10 nF
Internal inductance, max. L
0 µH

Rated Data Ul

Certificate No. (UL)
E311081
UL certificate
UL 497b Certificate

Tender Specification Sheets

Long specification
Surge protection plug for use in connection with the base element VSPC BASE 2CL for two floating-ground driven paired cables, for IT use. Two-stage protection circuit consisting of coarse protection, decoupling resistors and fine protection between the signal wires and coarse common mode voltage protection to earth. Mechanical identification of the plug to the base element according to the switching type and rated voltage. Optical identification of the protected plug based on the type of protected switching and the voltage level. Protected plug with coding pin and counter-profile for the base element. It is possible to mark the plug.
Short specification
Surge protection plug for use in connection with the base element VSPC BASE 2CL for two floating-ground driven paired cables, for IT use, 5 V DC.

Classifications

ETIM 6.0
EC000943
ETIM 7.0
EC000943
EClass 9.0
27-13-08-07
EClass 9.1
27-13-08-07
EClass 10.0
27-13-08-07
UNSPSC
30-21-19-21

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Temperatures

Humidity
5...96 %
Operating temperature, max.
70 °C
Operating temperature, min.
-40 °C
Storage temperature, max.
80 °C
Storage temperature, min.
-40 °C
Operating temperature
-40 °C...70 °C
Storage temperature
-40 °C...80 °C

Ratings Iecex/Atex/Cul

CUL certificate
cUL Certificate