Weidmuller

8965350000

1 / 9
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail
thumbnail

Description

EX signal isolating converter, Ex-input: NAMUR sensor/switch, Safe-output: relay, NC contact, 1-channel
Part Number
8965350000
£127.84
net
1
Payment methods:
Best offer from:
GBTrusted Automa.Net Supplier
Availability:
8 pcs.
In-Stock
Updated at: 21-11-2024
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
A total of 80 Parts In-Stock from 10 Distributors
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (9)

8965350000 product image
Weidmuller

8965350000

Condition:
New Factory Sealed
Available:
8 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
LVTrusted Automa.Net Supplier
Estimated Delivery:
On Request
Warranty:
12 months
1
€131.85
net
8965350000 product image
Weidmuller

8965350000

Condition:
New Factory Sealed
Available:
8 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
DETrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
€149.90
net
8965350000 product image
Weidmuller

8965350000

Condition:
New Factory Sealed
Available:
8 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
NLTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
€149.90
net
8965350000 product image
Weidmuller

8965350000

Condition:
New Factory Sealed
Available:
8 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
ESTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
€158.44
net
8965350000 product image
Weidmuller

8965350000

Condition:
New Factory Sealed
Available:
8 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
ITTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
€158.44
net
8965350000 product image
Weidmuller

8965350000

Condition:
New Factory Sealed
Available:
8 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
FRTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
€158.44
net
8965350000 product image
Weidmuller

8965350000

Condition:
New Factory Sealed
Available:
8 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
PLTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
674,55 zł
net
8965350000 product image
Weidmuller

8965350000

Condition:
New Factory Sealed
Available:
8 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
ROTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
8965350000 product image
Weidmuller

8965350000

Condition:
New Factory Sealed
Available:
8 pcs.
In-Stock
Updated at: 21-11-2024
Offer from:
CZTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
Offer with manufacturer lead time
Ships in:On Request
Best price:
€96.72

Probability Of Failure

MTBF
207 Years
SIL PAPER
SIL certificate
SIL in compliance with IEC 61508
2

Digital Output

Switching capacity
500 VA / 60 W (safe area), 16 VA / 60 W (zone 2)
Type
Relay, 1 NC contact, Switching frequency 20 Hz
Nominal switching voltage
≤ 250 V AC / 30 V DC (safe area)≤ 32 V AC / 32 V DC (zone 2)
Continuous current
≤ 2 A AC/DC (safe area, Zone 2 area)
Function
Output = input, direct or inverse (configurable)

Approvals

ROHS
Conform
UL File Number Search
E337701

Dimensions And Weights

Width
22.5 mm
Width (inches)
0.886 inch
Height
119.2 mm
Height (inches)
4.693 inch
Depth
113.6 mm
Depth (inches)
4.472 inch
Net weight
175 g

Safety-Related Specifications Low Demand Mode

Average Probability of Failure on Demand (PFD
2.04 x 10-4 (Tproof = 1 year), 4.08 x 10-4 (Tproof = 2 years), 1.02 x 10-4 (Tproof = 5 years)
Safe Failure Fraction (SFF)
90 %

Connection Data

Type of connection
Screw connection
Tightening torque, min.
0.4 Nm
Tightening torque, max.
0.6 Nm
Clamping range, rated connection
2.5 mm²
Clamping range, min.
0.25 mm²
Clamping range, max.
2.5 mm²
Wire connection cross section AWG, min.
AWG 26
Wire connection cross section AWG, max.
AWG 12

Rated Data Ul

UL certificate
E337701.pdf

Safety-Related Basic Specifications

Demand mode
High
Demand rate
1,000 s
Demand response time
< 10 ms (relay output)
Description of the "safe state"
de-energized (relay output)
Device type
B
Diagnostic test interval
10 s
Hardware fault tolerance (HFT)
0
Mean Time To Repair (MTTR)
8 h
Relay lifetime
100000 times
Safe Failure Fraction (SFF)
90 %
T
4 Years
Total failure rate for dangerous detected failures (λ
130 FIT
Total failure rate for dangerous undetected failures (λ
46 FIT
Total failure rate for safe detected failures (λ
0 FIT
Total failure rate for safe undetected failures (λ
289 FIT
Safety category
SIL 2
Probability of outage PFH
4.66 x 10-8 h-1

Tender Specification Sheets

Long specification
Ex isolating switch amplifiers for Namur sensors 1-channel isolating switch amplifiers in 22.5 mm width with an external power supply, to transmit and isolate Namur sensor signals from Ex zones 0,1,2 into the safe zone. On the output side there is a potential-free relay contact with opening function and an alarm contact ("a" contact) for status/error messages. The component can be configured using standard FDT/DTM software. Add-on housing for TS35 DIN rail installation Dimensions: L/W/H 119.2/ 22.5/ 113.6screw connection/ nominal cross-section 2.5 mm2Protection degree: IP20   Input                      NAMUR sensor according to EN 60947                                     8 VDC / 8 mA sensor power supply                                      0 to 5 kHz input frequency                                     wire-break detectionoutput                      Relay 1 NC contact                                      250 VAC / 30 VDC @ 2A safe zone                                    32 VAC @ 0.5 A/ 32 VDC @ 1 A zone 2Alarm output relay 1 NO contact                                       250 VAC / 30 VDC @ 2A safe zone                                     32 VAC @ 0.5 A/ 32 VDC @ 1 A zone 2 Auxiliary power                   19 to 31.2 VDCPower loss approx. 1.8 WAmbient temperature range -20 °C to +60 °C                      Secure isolation                   EN 61010, 3-way isolation up to 2.6 kV AC/DC of all circuits against each otherWorking voltage                    300 V AC/DC at overvoltage category II and pollution degree 2 Approvals cULus, ATEX IECEX, FM ATEX marking II 3 G ExnA nC IIC T4 ATEX characteristic data U0 = 10, 6 V DC                                       I0  = 12 mA DC                                       P0 = 32 W Type                                                             ACT20X-HDI-SDO-RNC-S
Short specification
Ex isolating switch amplifiers for Namur sensors1-channel isolating switch amplifiers in 22.5 mm width with an external power supply,to transmit and isolate Namur sensor signals from Ex zones 0,1,2 into the safe zone. On the output side there is a potential-free relay contact with opening function and an alarm contact ("a" contact)for status/error messages.The component can be configured using standard FDT/DTM software.

Alarm Output

Alarm function
Line interruption at the input, Short circuit at input, No supply voltage, Device error
Type
Relay, 1 NC (voltage-free)
Nominal switching voltage
≤ 125 V AC / 110 V DC (safe area)≤ 32 V AC / 32 V DC (zone 2)
Continuous current
≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2)
Power rating
≤ 62.5 VA / 32 W (safe area)≤ 16 VA / 32 W (Zone 2)

Classifications

ETIM 6.0
EC002653
ETIM 7.0
EC002653
EClass 9.0
27-21-01-20
EClass 9.1
27-21-01-20
EClass 10.0
27-21-01-20
UNSPSC
30-21-18-01

Product Information

Product information
Weidmüller provides an extended guarantee period of 36 months for this device.

Environmental Product Compliance

REACH SVHC
Lead 7439-92-1

Data For Ex Applications (Atex)

Voltage U
10.6 V DC
Current I
12 mA DC
Power P
32 mW
Marking
II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
Installation location
Device installed in safe area, zone 2

Insulation Coordination

EMC standards
DIN EN 61326, NE 21
Insulation voltage
2.6 kV (input / output)
Rated voltage
300 V

Input Ex

Input frequency
< 20 Hz
Input resistance
1 kΩ
Output signal in case of wire break
< 0.1 mA, > 6.5 mA (in case of wire break)
Pulse duration
> 0.1 ms
Resistance
RP = 750 Ω / RS = 15kΩ
Sensor
NAMUR sensor, according to EN60947, switch with or without RS, RP
Sensor supply
8 V DC / 8 mA
Trigger level high
> 2.1 mA
Trigger level low
< 1.2 mA
Type
intrinsically safe circuit

Temperatures

Humidity
0...95 % (no condensation)
Operating temperature, max.
60 °C
Operating temperature, min.
-20 °C
Storage temperature, max.
85 °C
Storage temperature, min.
-20 °C
Operating temperature
-20 °C...60 °C
Storage temperature
-20 °C...85 °C

Ratings Iecex/Atex/Cul

ATEX certificate
09ATEX0168X.pdf
IEC Ex certificate
IECEx certification
Certificate No. (ATEX)
KEMA09ATEX0168X
Certificate No. (IECEX)
IECEXKEM09.0072X
Certificate no. (cULus)
E337701

General Specifications

Configuration
With FDT/DTM software
Voltage supply
19.2…31.2 V DC
Type of connection
Screw connection
NAMUR supply
8 V DC / 8 mA
Power consumption
≤ 1.3 W
Protection degree
IP20
Humidity
0...95 % (no condensation)