BMI1003P06F
- New Factory Sealed10 pcs.
- New Surplus2 pcs.
#1 Conference for Industrial Automation Trade| 16-18 June 2025| Hilton Warsaw City, Warsaw, PolandLearn More
Categories
Back to:All CategoriesFilters
MOTOR STARTER SIRIUS 3RM1 DIRECT STARTER SAFETY 500 V; 0,1-0,5 A; 110-230 V AC PUSH-IN TYPE CONNECTION SYSTEM
MOTOR STARTER SIRIUS 3RM1 DIRECT STARTER SAFETY 500 V; 0,1-0,5 A; 110-230 V AC PUSH-IN TYPE CONNECTION SYSTEM
SIRIUS soft starter 200-600 V 370 A. 110-250 V AC spring-type terminals Thermistor input
SIRIUS soft starter 200-600 V 370 A. 110-250 V AC spring-type terminals Thermistor input
SIRIUS soft starter 200-690 V 315 A, 24 V AC/DC spring-type terminals
SIRIUS soft starter 200-690 V 315 A, 24 V AC/DC spring-type terminals
SIRIUS soft starter 200-690 V 630 A. 24 V AC/DC Spring-type terminals
SIRIUS soft starter 200-690 V 630 A. 24 V AC/DC Spring-type terminals
SIRIUS SOFT STARTER, S2 63A, 30KW/400V 40 DEGR. AC 200-480V, AC/DC110-230V, Screw Terminals
SIRIUS SOFT STARTER, S2 63A, 30KW/400V 40 DEGR. AC 200-480V, AC/DC110-230V, Screw Terminals
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
Networkable hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 3 A output current, with adjustable overload shutdown, emergency stop function up to SIL 3/PL e, and Push-in connection. Connection to IO-Link.
TeSys D pre-assembled star-delta starter, for motor control applications up to 25kW@400V in delta connection. Plate mounted starter, open version, composed of 3 contactors LC1D with 230V 50/60Hz AC coils, 1NC built-in auxiliary contact on star, a time-delay contact block 1-30 sec. For operating rates until 30 starts/hour, maximum starting time 30 sec. Compact assembly (165mm width), screw fixing. Equipped with pre-wired star delta power connections, and mechanical interlock, the use of a thermal overload relay (to be ordered separately) is strongly recommended. Green Premium compliant (RoHS/REACh).
TeSys D pre-assembled star-delta starter, for motor control applications up to 25kW@400V in delta connection. Plate mounted starter, open version, composed of 3 contactors LC1D with 230V 50/60Hz AC coils, 1NC built-in auxiliary contact on star, a time-delay contact block 1-30 sec. For operating rates until 30 starts/hour, maximum starting time 30 sec. Compact assembly (165mm width), screw fixing. Equipped with pre-wired star delta power connections, and mechanical interlock, the use of a thermal overload relay (to be ordered separately) is strongly recommended. Green Premium compliant (RoHS/REACh).
Load feeder fuseless direct start, AC 400V, sz. s0, 9. . .12,5a, DC 24v screw connection for rail mounting, type of coord. 2,iq = 150ka (also AChieves type of coord.1) 1NO+1NC (contactor)
Load feeder fuseless direct start, AC 400V, sz. s0, 9. . .12,5a, DC 24v screw connection for rail mounting, type of coord. 2,iq = 150ka (also AChieves type of coord.1) 1NO+1NC (contactor)
TeSys U standard control unit to be inserted in power bases LUB12, LUB32, LUB38 to form a TeSys U starter controller, for 3-phase motor applications up to 0.09kW@400V. It provides full protection to motors with a rated current Ir 0.15-0.6A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
TeSys U standard control unit to be inserted in power bases LUB12, LUB32, LUB38 to form a TeSys U starter controller, for 3-phase motor applications up to 0.09kW@400V. It provides full protection to motors with a rated current Ir 0.15-0.6A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. Ethernet/IP and Modbus/TCP protocol is used by this controller. Ethernet TCP/IP communication is used. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 5 to 100 amperes. 24 VDC is used to power this controller. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. Ethernet/IP and Modbus/TCP protocol is used by this controller. Ethernet TCP/IP communication is used. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 5 to 100 amperes. 24 VDC is used to power this controller. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
SIRIUS motor starter M200D AS-i Communication: AS-Interface Reversing starter standard Electronic switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC without brake contact 4 DI / 1 DO AS-i Han Q4/2 - Han Q8/0 with manual on-site operation and key-operated switch
SIRIUS motor starter M200D AS-i Communication: AS-Interface Reversing starter standard Electronic switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC without brake contact 4 DI / 1 DO AS-i Han Q4/2 - Han Q8/0 with manual on-site operation and key-operated switch
SIRIUS MOTOR STARTER M200D TECHNOLOGY MODULE DIRECT ON-LINE-STARTER MECHANICAL SWITCHING 3 400V AC/5,5KW; 1,5A...12,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITHOUT BRAKE CONTACT 4DI / 2DO HAN Q4/2 - HAN Q8/0 WITH OPERATOR TERMINAL AND KEY-OPERATED SWITCH USING A COMMUNICATIONS MODULE 3RK1305* USABLE WITH PROFIBUS OR PROFINET
SIRIUS MOTOR STARTER M200D TECHNOLOGY MODULE DIRECT ON-LINE-STARTER MECHANICAL SWITCHING 3 400V AC/5,5KW; 1,5A...12,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITHOUT BRAKE CONTACT 4DI / 2DO HAN Q4/2 - HAN Q8/0 WITH OPERATOR TERMINAL AND KEY-OPERATED SWITCH USING A COMMUNICATIONS MODULE 3RK1305* USABLE WITH PROFIBUS OR PROFINET
SIRIUS soft starter 200-480 V 370 A. 110-250 V AC Screw terminals Analog output
SIRIUS soft starter 200-480 V 370 A. 110-250 V AC Screw terminals Analog output
SIRIUS soft starter 200-600 V 32 A, 24 V AC/DC spring-type terminals
SIRIUS soft starter 200-600 V 32 A, 24 V AC/DC spring-type terminals
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. Ethernet/IP and Modbus/TCP protocol is used by this controller. Ethernet TCP/IP communication is used. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 1.35 to 27 amperes. 24 VDC is used to power this controller. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. Ethernet/IP and Modbus/TCP protocol is used by this controller. Ethernet TCP/IP communication is used. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 1.35 to 27 amperes. 24 VDC is used to power this controller. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
LOAD FEEDER FUSELESS DIRECT START, AC 400V, SZ S00 0.7. . .1A, AC 230V SPRING-LOADED CONNECTION FOR RAIL-MOUNTING, TYPE OF COORDINATION 2, IQ = 150KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NO (CONTACTOR)
LOAD FEEDER FUSELESS DIRECT START, AC 400V, SZ S00 0.7. . .1A, AC 230V SPRING-LOADED CONNECTION FOR RAIL-MOUNTING, TYPE OF COORDINATION 2, IQ = 150KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NO (CONTACTOR)
SIRIUS soft starter 200-480 V 143 A. 24 V AC/DC Screw terminals Thermistor input
SIRIUS soft starter 200-480 V 143 A. 24 V AC/DC Screw terminals Thermistor input
SIRIUS soft starter 200-690 V 250 A, 110-250 V AC spring-type terminals
SIRIUS soft starter 200-690 V 250 A, 110-250 V AC spring-type terminals