- Contacts Type And Composition
- 1 NO + 1 NC fault signal || 3 NO
- Height
- 61 mm
- Connection Pitch
- 5.08 mm
- Permissible Power
- 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
- Network And Machine Diagnosis Type
- fault recording || trip context information || waiting time after overload tripping || trip history information || running hours counter/operating time || motor control command recording || starting current and time || phase fault and earth fault trip counters || event recording || remaining operating time before overload tripping
- Pollution Degree
- 3
- Logic Input Number
- 6
- Maximum Operating Rate
- 1800 cyc/h
- Connections - Terminals
- control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end
- Input Current
- 7 mA
- Current State 1 Guaranteed
- logic input < 15 V 2...15 mA 15 ms
- Net Weight
- 0.53 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
- Associated Fuse Rating
- 4 A gG output || 0.5 A gG control circuit
- Electromagnetic Compatibility
- electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
- Measurement Accuracy
- 5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 5 % active and reactive power || 0,02 current
- Current State 0 Guaranteed
- logic input < 5 V <= 15 mA 5 ms
- [Ui] Rated Insulation Voltage
- 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
- Short-Circuit Withstand
- 100 kA conforming to EN/IEC 60947-4-1
- Compatibility Code
- LTMR
- Protection Type
- locked rotor || overload || thermal overload protection || earth-leakage protection || reverse polarity protection || overload (long time) || power factor variation || phase unbalance || load fluctuation || phase failure || thermal protection
- Web Services
- web server
- Width
- 91 mm
- Load Current
- 5 A 250 V AC logic output || 5 A 30 V DC logic output
- Tightening Torque
- control circuit 0.5-0.6 N.m flat 3 mm
- Overvoltage Category
- III
- Depth
- 122.5 mm
- Maximum Operating Frequency
- 2 Hz
- Metering Type
- average current Iavg || earth-fault current || temperature || phase current I1, I2, I3 RMS || imbalance current