- Number of Main Contacts NO
- 3
- Number of Main Contacts NC
- 0
- Number of Auxiliary Contacts NO
- 0
- Number of Auxiliary Contacts NC
- 0
- Standards
- IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1
- Rated Operational Voltage
- Main Circuit 690 V
- Rated Frequency (f)
- Control Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith)
- acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 50 A
- Rated Operational Current AC-1 (Ie)
- (690 V) 40 °C 45 A(690 V) 60 °C 40 A(690 V) 70 °C 32 A
- Rated Operational Current AC-3 (Ie)
- (415 V) 60 °C 26 A(440 V) 60 °C 26 A(500 V) 60 °C 23 A(690 V) 60 °C 17 A(380 / 400 V) 60 °C 26 A(220 / 230 / 240 V) 60 °C 26 A
- Rated Operational Current AC-3e (Ie)
- (415 V) 60 °C 26 A(440 V) 60 °C 26 A(500 V) 60 °C 23 A(690 V) 60 °C 17 A(380 / 400 V) 60 °C 26 A(220 / 230 / 240 V) 60 °C 26 A
- Rated Operational Power AC-3 (Pe)
- (400 V) 11 kW(415 V) 11 kW(440 V) 15 kW(500 V) 15 kW(690 V) 15 kW(380 / 400 V) 11 kW(220 / 230 / 240 V) 6.5 kW
- Rated Operational Power AC-3e (Pe)
- (415 V) 11 kW(440 V) 15 kW(500 V) 15 kW(690 V) 15 kW(380 / 400 V) 11 kW(220 / 230 / 240 V) 6.5 kW
- Rated Short-time Withstand Current Low Voltage (Icw)
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
- Maximum Breaking Capacity
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
- Maximum Electrical Switching Frequency
- (AC-1) 600 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 1200 cycles per hour
- Rated Operational Current DC-1 (Ie)
- (110 V) 2 Poles in Series, 40 °C 45 A(110 V) 2 Poles in Series, 60 °C 40 A(110 V) 2 Poles in Series, 70 °C 32 A(110 V) 3 Poles in Series, 40 °C 45 A(110 V) 3 Poles in Series, 60 °C 40 A(110 V) 3 Poles in Series, 70 °C 32 A(220 V) 3 Poles in Series, 40 °C 45 A(220 V) 3 Poles in Series, 60 °C 40 A(220 V) 3 Poles in Series, 70 °C 32 A(72 V) 1-Pole, 40 °C 45 A(72 V) 1-Pole, 60 °C 40 A(72 V) 1-Pole, 70 °C 32 A(72 V) 2 Poles in Series, 40 °C 45 A(72 V) 2 Poles in Series, 60 °C 40 A(72 V) 2 Poles in Series, 70 °C 32 A(72 V) 3 Poles in Series, 40 °C 45 A(72 V) 3 Poles in Series, 60 °C 40 A(72 V) 3 Poles in Series, 70 °C 32 A
- Rated Operational Current DC-3 (Ie)
- (110 V) 2 Poles in Series, 40 °C 45 A(110 V) 2 Poles in Series, 60 °C 40 A(110 V) 2 Poles in Series, 70 °C 32 A(110 V) 3 Poles in Series, 40 °C 45 A(110 V) 3 Poles in Series, 60 °C 40 A(110 V) 3 Poles in Series, 70 °C 32 A(220 V) 3 Poles in Series, 40 °C 45 A(220 V) 3 Poles in Series, 60 °C 40 A(220 V) 3 Poles in Series, 70 °C 32 A(72 V) 1-Pole, 40 °C 45 A(72 V) 1-Pole, 60 °C 40 A(72 V) 1-Pole, 70 °C 32 A(72 V) 2 Poles in Series, 40 °C 45 A(72 V) 2 Poles in Series, 60 °C 40 A(72 V) 2 Poles in Series, 70 °C 32 A(72 V) 3 Poles in Series, 40 °C 45 A(72 V) 3 Poles in Series, 60 °C 40 A(72 V) 3 Poles in Series, 70 °C 32 A
- Rated Operational Current DC-5 (Ie)
- (110 V) 2 Poles in Series, 40 °C 45 A(110 V) 2 Poles in Series, 60 °C 40 A(110 V) 2 Poles in Series, 70 °C 32 A(110 V) 3 Poles in Series, 40 °C 45 A(110 V) 3 Poles in Series, 60 °C 40 A(110 V) 3 Poles in Series, 70 °C 32 A(220 V) 3 Poles in Series, 40 °C 20 A(220 V) 3 Poles in Series, 60 °C 20 A(220 V) 3 Poles in Series, 70 °C 20 A(72 V) 1-Pole, 40 °C 20 A(72 V) 1-Pole, 60 °C 20 A(72 V) 1-Pole, 70 °C 20 A(72 V) 2 Poles in Series, 40 °C 45 A(72 V) 2 Poles in Series, 60 °C 40 A(72 V) 2 Poles in Series, 70 °C 32 A(72 V) 3 Poles in Series, 40 °C 45 A(72 V) 3 Poles in Series, 60 °C 40 A(72 V) 3 Poles in Series, 70 °C 32 A
- Rated Insulation Voltage (Ui)
- acc. to IEC 60947-4-1 690 Vacc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp)
- 6 kV
- Maximum Mechanical Switching Frequency
- 3600 cycles per hour
- Rated Control Circuit Voltage (Uc)
- 50 Hz 24 ... 60 V60 Hz 24 ... 60 VDC Operation 20 ... 60 V
- Operate Time
- Between Coil De-energization and NC Contact Closing 13 ... 98 msBetween Coil De-energization and NO Contact Opening 11 ... 95 msBetween Coil Energization and NC Contact Opening 38 ... 90 msBetween Coil Energization and NO Contact Closing 40 ... 95 ms
- Mounting on DIN Rail
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Mounting by Screws (not supplied)
- 2 x M4 screws placed diagonally
- Connecting Capacity Main Circuit
- Flexible with Ferrule 1/2x 1.5 ... 10 mm²Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²Flexible with Insulated Ferrule 2x 1.5 ... 4 mm²Rigid Solid 1/2x 2.5 ... 4 mm²Rigid Stranded 1/2x 2.5 ... 10 mm²
- Connecting Capacity Control Circuit
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
- Wire Stripping Length
- Control Circuit 10 mmMain Circuit 14 mm
- Degree of Protection
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
- Terminal Type
- Screw Terminals