- Current measurement DC and AC 10 Hz to 100 Hz Range
- 40 A / 400 A / 2000 A / 1400 AC rms
- Current measurement DC and AC 10 Hz to 100 Hz Resolution
- 10 mA / 100 mA / 1 A
- Current measurement DC and AC 10 Hz to 100 Hz Accuracy
- A: 1.5% rdg + 15 digitsA: 1.5% rdg + 5 digits
- Current measurement DC and AC 10 Hz to 100 Hz Trigger level for Inrush
- 0.50 A / 5.0 A / 5 A
- Current measurement DC and AC 10 Hz to 100 Hz
- Trigger level for Hz filter OFF: 2.50 A / 2.5 A / 8 A || Trigger level for Hz filter ON: 0.50 A / 2.5 A / 8 A
- Crest Factor (50/60 Hz) Range
- 40 A / 400 A / 2000 A / 1400 AC rms
- Crest Factor (50/60 Hz) Crest Factor1
- 2 @ 33 A, 2.4 @ 27 A2 @ 330 A, 2.4 @ 270 A2 @ 1000 A, 2.4 @ 833 A
- Current measurement AC 100.1 Hz to 1 kHz Range
- 40 A / 400 A / 2000 A; 1400 AC rms
- Current measurement AC 100.1 Hz to 1 kHz Resolution
- 10 mA / 100 mA / 1 A
- Current measurement AC 100.1 Hz to 1 kHz Accuracy
- 10 A: 3.5% rdg + 15 digits10 A: 3.5% rdg + 5 digits
- Current measurement AC 100.1 Hz to 1 kHz Trigger level for Inrush
- 0.50 A / 5.0 A / 5 A
- Current measurement AC 100.1 Hz to 1 kHz
- Trigger level for Hz filter OFF: 2.50 A / 2.5 A / 8 A || Trigger level for Hz filter ON: 0.50 A / 2.5 A / 8 A
- Voltage measurement DC and AC 10 Hz to 100 Hz(600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) Range
- 4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC
- Voltage measurement DC and AC 10 Hz to 100 Hz Resolution
- 1 mV / 10 mV / 100 mV / 1 V
- Voltage measurement DC and AC 10 Hz to 100 Hz Accuracy
- 1% rdg + 10 digits1% rdg + 5 digits
- Voltage measurement DC and AC 10 Hz to 100 Hz
- Trigger level for Hz filter OFF: 0.25 V / 6 V || Trigger level for Hz filter ON: 0.25 V / 6 V
- Voltage measurement AC 100.1 Hz to 1 kHz(600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) Range
- 4 V / 40 V / 400 V / 600 V ac rms
- Voltage measurement AC 100.1 Hz to 1 kHz Resolution
- 1 mV / 10 mV / 100 mV / 1 V
- Voltage measurement AC 100.1 Hz to 1 kHz Accuracy
- 3% rdg + 10 digits3% rdg + 5 digits
- Voltage measurement AC 100.1 Hz to 1 kHz
- Trigger level for Hz filter OFF: 0.050 V / 0.25 V / 6 V || Trigger level for Hz filter ON: 0.050 V / 0.25 V / 6 V
- Ohms measurement Range
- 4 kΩ / 40 kΩ / 400 kΩ
- Ohms measurement Resolution
- 0.1 Ω / 1 Ω / 10 Ω / 100 Ω
- Ohms measurement Accuracy
- 1.5% + 5 digits
- Continuity beeper
- On at ≤ 30 ΩOff at ≥ 100 Ω
- Frequency measurement Measurement range
- 5.0 Hz to 1 kHz
- Frequency measurement Resolution
- 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
- Frequency measurement
- Accuracy – 5.0 Hz to 100 Hz: 0.2% + 2 counts || Accuracy – 100.1 Hz to 1 kHz: 0.5% + 5 counts
- Frequency measurement Trigger level
- Refer to current and voltage tables