Fluke

FLUKE 355

1 / 3
thumbnail
thumbnail
thumbnail
Part Number
FLUKE 355
UPC
095969401203
Payment methods:
Best offer from:
CNTrusted Automa.Net Supplier
Availability:
10 pcs.
In-Stock
Updated at: 08-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
A total of 12 Parts In-Stock from 2 Distributors
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Available Offers (1)

FLUKE 355 product image
Condition:
New Surplus
Available:
2 pcs.
In-Stock
Updated at: 08-11-2024
Offer from:
PLTrusted Automa.Net Supplier
Estimated Delivery:
On Request
1
Offer with manufacturer lead time
Ships in:On Request
Best price:
£987.00

Electrical Specifications

Current measurement DC and AC 10 Hz to 100 Hz Range
40 A / 400 A / 2000 A / 1400 AC rms
Current measurement DC and AC 10 Hz to 100 Hz Resolution
10 mA / 100 mA / 1 A
Current measurement DC and AC 10 Hz to 100 Hz Accuracy
A: 1.5% rdg + 15 digitsA: 1.5% rdg + 5 digits
Current measurement DC and AC 10 Hz to 100 Hz Trigger level for Inrush
0.50 A / 5.0 A / 5 A
Current measurement DC and AC 10 Hz to 100 Hz
Trigger level for Hz filter OFF: 2.50 A / 2.5 A / 8 A || Trigger level for Hz filter ON: 0.50 A / 2.5 A / 8 A
Crest Factor (50/60 Hz) Range
40 A / 400 A / 2000 A / 1400 AC rms
Crest Factor (50/60 Hz) Crest Factor1
2 @ 33 A, 2.4 @ 27 A2 @ 330 A, 2.4 @ 270 A2 @ 1000 A, 2.4 @ 833 A
Current measurement AC 100.1 Hz to 1 kHz Range
40 A / 400 A / 2000 A; 1400 AC rms
Current measurement AC 100.1 Hz to 1 kHz Resolution
10 mA / 100 mA / 1 A
Current measurement AC 100.1 Hz to 1 kHz Accuracy
10 A: 3.5% rdg + 15 digits10 A: 3.5% rdg + 5 digits
Current measurement AC 100.1 Hz to 1 kHz Trigger level for Inrush
0.50 A / 5.0 A / 5 A
Current measurement AC 100.1 Hz to 1 kHz
Trigger level for Hz filter OFF: 2.50 A / 2.5 A / 8 A || Trigger level for Hz filter ON: 0.50 A / 2.5 A / 8 A
Voltage measurement DC and AC 10 Hz to 100 Hz(600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) Range
4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC
Voltage measurement DC and AC 10 Hz to 100 Hz Resolution
1 mV / 10 mV / 100 mV / 1 V
Voltage measurement DC and AC 10 Hz to 100 Hz Accuracy
1% rdg + 10 digits1% rdg + 5 digits
Voltage measurement DC and AC 10 Hz to 100 Hz
Trigger level for Hz filter OFF: 0.25 V / 6 V || Trigger level for Hz filter ON: 0.25 V / 6 V
Voltage measurement AC 100.1 Hz to 1 kHz(600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) Range
4 V / 40 V / 400 V / 600 V ac rms
Voltage measurement AC 100.1 Hz to 1 kHz Resolution
1 mV / 10 mV / 100 mV / 1 V
Voltage measurement AC 100.1 Hz to 1 kHz Accuracy
3% rdg + 10 digits3% rdg + 5 digits
Voltage measurement AC 100.1 Hz to 1 kHz
Trigger level for Hz filter OFF: 0.050 V / 0.25 V / 6 V || Trigger level for Hz filter ON: 0.050 V / 0.25 V / 6 V
Ohms measurement Range
4 kΩ / 40 kΩ / 400 kΩ
Ohms measurement Resolution
0.1 Ω / 1 Ω / 10 Ω / 100 Ω
Ohms measurement Accuracy
1.5% + 5 digits
Continuity beeper
On at ≤ 30 ΩOff at ≥ 100 Ω
Frequency measurement Measurement range
5.0 Hz to 1 kHz
Frequency measurement Resolution
0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Frequency measurement
Accuracy – 5.0 Hz to 100 Hz: 0.2% + 2 counts || Accuracy – 100.1 Hz to 1 kHz: 0.5% + 5 counts
Frequency measurement Trigger level
Refer to current and voltage tables

Environmental Specifications

Operating temperature
32°F to +122°F (0°C to +50°C)
Storage temperature
-4°F to 140°F (-20°C to +60°C)
Operating humidity
0 to 95% (non-condensing)
Operating altitude
2000 m
Storage altitude
10,000 m
IP rating
42 (indoor use only)
Drop test requirements
1 m
EMI, RFI, EMC
FCC part 15, IEC/EN 61326-1:1997 class BIEC/EN 61326:1997 3 V/m, performance criteria B, EN61325
Temperature coefficients Current
0.1% of reading per °C outside 22°C to 24°C
Temperature coefficients
Voltage: 0.1% of reading per °C outside 22°C to 24°C

General Specifications

Batteries
Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off)
100 hours
Test leads
Rated to 1000 V
Weight
.814 kg (1.8 lb)
Jaw size
58 mm (2.28 in)
Dimensions (L x W x D)
300 x 98 x 52 mm (12 x 3.75 x 2 in)
Safety rating
IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III