Need more information?

Call us at:+48 17 778 34 19

Honeywell E50-208100-J06-N-KIT

5000 Class Submeter, 3 Phase, 100 A, 120/208-240 V AC

1 / 1
Honeywell E50-208100-J06-N-KIT 5000 Class Submeter, 3 Phase, 100 A, 120/208-240 V AC — Power Supply
Manufacturer catalogue image

Product Description

The 5000 Class Smart Meter (H50) is engineered for advanced energy monitoring in commercial and industrial settings. With the capability to communicate simultaneously with two energy monitoring systems, it supports both Building Automation Systems (BAS) and measurement & verification (M&V) reporting tools.

This device features an advanced 4-line LCD display with backlight for enhanced visibility and offers dual protocol communications, including Modbus RTU and Modbus TCP/IP, for versatile connectivity. The meter is built to operate within a temperature range of -4 °F to 122 °F (-20 °C to 50 °C) and can withstand humidity levels up to 95% non-condensing.

Designed to accommodate a 3 or 4 wire input voltage configuration, the meter utilizes split-core current sensors, providing a current output of 2 V. With a total of 38 points of information available, this meter ensures precise monitoring of electrical usage with an accuracy of ±1% across its rated load range, complying with ANSI C12.20 and CE regulatory standards. The enclosure is made from JIC Steel, ensuring durability in demanding environments.

Send Inquiry
Payment methods:

Offer details

Best offer from:
Trusted supplier — United States, member since 2024
Availability:
0 pcs.
On Request
Updated at: 02-09-2026
Warranty:
12 months
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing

Specifications

Regulatory Approvals
ANSI C12.20 ; CE
Phases
3
Number of Current Sensors Included
3
Modem Included
No
Minimum Operating Ambient Temperature
-4 °F ; -20 °C
Maximum Operating Humidity
95 % non-condensing

Access our platform to find more offers

Register now to explore 36 mln offers from verified suppliers worldwide.

  • Compare offers globally
  • Direct supplier contact
  • RFQs, Quotes, and Orders
  • BOM Search
Sign UpFree 14-day trial available
Offer with manufacturer lead time
Directly from the manufacturer - with a confirmed, predictable, and fully transparent delivery time.
Get Quote

Documents

Data Sheet

Datasheet for Honeywell E50-208100-J06-N-KIT, including specifications and features.

Download Data Sheet
TracePartsTraceParts

CAD Models

3D CAD model and technical drawings, ready for your design software.

Download CAD Model

Related products

E50-208100-J05SCS-NS Honeywell
E50-208100-J05SCS-NS
Honeywell
This three-phase submeter operates at 100 A and supports input voltages of 120/208-240 V AC without integrated sensors.
E50-208800-J07KIT-NS Honeywell
E50-208800-J07KIT-NS
Honeywell
Three-phase submeter designed for electrical monitoring with a current capacity of 800 A and voltage ratings of 120/208-240 V AC.
E50-400400-J07-SPKIT-NS Honeywell
E50-400400-J07-SPKIT-NS
Honeywell
The CLASS 5000 SUBMETER is designed for 1 or 2 phase operation with a current rating of 400 A and voltage configuration of 230/400 V AC.
E34-600400-J05-X-KIT-NS Honeywell
E34-600400-J05-X-KIT-NS
Honeywell
Three-phase submeter designed for 400 A current and 347/600 V AC voltage without current sensors.
E34-600100-J07SCS-NS Honeywell
E34-600100-J07SCS-NS
Honeywell
The CLASS 3400 SUBMETER is a 3-phase, 100 A submeter designed for applications with an input voltage of 347/600 V AC.
E34-600100-R07KIT Honeywell
E34-600100-R07KIT
Honeywell
The CLASS 3400 SUBMETER is designed for three-phase systems, accommodating up to 100 A at 347/600 V AC.
E34-480800-J03-X-KIT-NS Honeywell
E34-480800-J03-X-KIT-NS
Honeywell
The CLASS 3400 SUBMETER is a three-phase electronic meter designed for monitoring electrical usage with a maximum current of 800 A and input voltage of 277/480 V AC.
E32-600400-MBAC-SPKIT-NS Honeywell
E32-600400-MBAC-SPKIT-NS
Honeywell
The CLASS 3200 SUBMETER is designed for 1 or 2 phase operation, capable of handling up to 400 A at 347/600 V AC.
E34-208800-J07-X-KIT-NS Honeywell
E34-208800-J07-X-KIT-NS
Honeywell
The CLASS 3400 SUBMETER accommodates 3-phase, 800 A electrical systems and operates at 120/208-240 V AC without integrated sensors.
E34-208800-J08-X-KIT-NS Honeywell
E34-208800-J08-X-KIT-NS
Honeywell
The CLASS 3400 SUBMETER is designed for 3-phase systems with a current rating of 800 A and operates at 120/208-240 V AC.
E34-480100-J02-SPKIT Honeywell
E34-480100-J02-SPKIT
Honeywell
The CLASS 3400 SUBMETER is designed for 1 or 2 phase applications with a current rating of 100 A and operates at 277/480 V AC.
E20-600800-M-G-KIT-NS Honeywell
E20-600800-M-G-KIT-NS
Honeywell
This device measures kW and kWh for three-phase power without included sensors, suitable for commercial and industrial applications.

Market insights

AutomaINSIGHTS analytics dashboard

Get real-time analytics and market data to optimize your purchasing decisions for this component and similar products

  • Real-time stock availability data from 700 MRO distributors in Europe and USA
  • Price analysis by condition (new, used, refurbished) with market median prices
  • Critical component availability monitoring to prevent production downtime
  • Inventory optimization insights based on market supply trends