- Electrical Connection
- control removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 25...50 mm² AWG 4...AWG 1 || motor screw terminal 25...50 mm² AWG 4...AWG 1
- Maximum Output Frequency
- 500 kHz
- Discrete Input Logic
- positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
- Height
- 597 mm
- Analogue Output Type
- software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
- Acceleration And Deceleration Ramps
- linear adjustable separately from 0.01...9999 s
- Discrete Output Type
- relay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V DC 5000 mA
- Transmission Frame
- RTU
- Maximum Switching Current
- relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
- Relay Output Number
- 3
- Exchange Mode
- half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
- Data Format
- 8 bits, configurable odd, even or no parity
- Power Range
- 30-50 kW 380-440 V 3 phase || 30-50 kW 480-500 V 3 phase
- Phase
- 3 phase
- Net Weight
- 25.8 kg
- Type Of Polarization
- no impedance
- Relay Output Type
- configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
- Frequency Resolution
- display unit 0.1 Hz || analog input 0.012/50 Hz
- Accuracy
- +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
- Connector Type
- RJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
- Input Compatibility
- DI1...DI6 discrete input level 1 PLC EN/IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC EN/IEC 61131-2
- Permissible Temporary Current Boost
- 1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
- Analogue Input Number
- 3
- Motor Slip Compensation
- adjustable || automatic whatever the load || can be suppressed || not available in permanent magnet motor law
- Discrete Output Number
- 0
- Mounting Mode
- cabinet mount
- Analogue Output Number
- 2
- Physical Interface
- Ethernet || 2-wire RS 485
- Minimum Switching Current
- relay output R1, R2, R3 5 mA 24 V DC
- Method Of Access
- slave Modbus TCP
- Refresh Time
- relay output R1, R2, R3)5 ms +/- 0.5 ms)
- Enclosure Mounting
- with heat sink
- Isolation
- between power and control terminals
- Discrete Input Number
- 8
- Local Signalling
- for local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
- Linearity Error
- AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
- Number Of Addresses
- 1-247 Modbus serial
- Output Voltage
- <= power supply voltage
- Quantity Per Set
- 1
- Width
- 210 mm
- Transmission Rate
- 10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
- Braking To Standstill
- by DC injection
- Depth
- 262 mm
- Discrete Input Type
- DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
- Protection Type
- thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || motor phase break drive || overvoltages on the DC bus drive || line supply overvoltage drive || line supply undervoltage drive || line supply phase loss drive || overspeed drive || break on the control circuit drive
- Supply
- external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection
- Analogue Input Type
- AI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
- Sampling Duration
- 2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output