Schneider Electric
XCSD3918G13
1 / 1
Description
Active Mature
This XCSD Compact Safety Limit Switch has a thermoplastic roller lever, a Zamak body and head and a Pg 13.5 cable gland entry. It has 1 normally open and 2 normally closed snap action contacts. Its B10D reliability data is 50 000 000. It has IK06 impact resistance and IP66 / IP67 degree of protection, makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.- Country of Origin
- FR
- Part Number
- XCSD3918G13
- Tariff Code
- 85365080
- EAN
- 3389110240733
- UNSPSC
- 39122213
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Specifications
- Contacts Type And Composition
- 1 NC + 1 NC + 1 NO
- Range Of Product
- Telemecanique Safety switches XCS
- Cable Entry
- 1 entry tapped Pg 13.5
- Contact Operation
- snap action
- Type Of Operator
- thermoplastic roller lever
- Product Or Component Type
- safety limit switch
- Protection Technology
- plastic protective cover, secured by 5-lobe socket head safety screw
- Component Name
- XCSD
- Material
- metal
- Design
- compact
- Head Type
- rotary head
Contractual warranty
- Warranty
- 18 months
Complementary
- Switch Actuation
- by 30° cam
- Height
- 122-122 mm
- [Ui] Rated Insulation Voltage
- 300 VUL 508 || 400 V 3)EN/IEC 60947-1 || 300 VCSA C22.2 No 14
- Short-Circuit Protection
- 6 A cartridge fuse gG (gl)
- Positive Opening
- with NC contact
- Clamping Connection Capacity
- 1 x 0.34...2 x 0.75 mm²
- Repeat Accuracy
- 0.1 mm on tripping points, 1 million operating cycles for head with end plunger
- Positive Opening Minimum Torque
- 0.25 N.m
- Mechanical Durability
- 10000000 cycles
- Maximum Actuation Speed
- 1.5 m/s
- Body Material
- zamak
- Electrical Connection
- terminal
- [Ithe] Conventional Enclosed Thermal Current
- 6 A
- Enclosure Material
- Plastic
- Contact Code Designation
- B300, AC-15 (Ue = 240 V, Ie = 1.5 A)EN/IEC 60947-5-1 appendix A || R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN/IEC 60947-5-1 appendix A
- Width
- 34 mm
- Depth
- 35 mm
- Head Material
- zamak
- Minimum Torque For Tripping
- 0.1 N.m
- Net Weight
- 0.255 kg
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV EN/IEC 60947-1 || 4 kV IEC 60664
- Number Of Poles
- 3
- Maximum Resistance Across Terminals
- 25 MOhm IEC 60255-7 category 3
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP110614EN
- Sustainable Offer Status
- Green Premium product
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Environment
- Product Certifications
- CSA || UL
- Ik Degree Of Protection
- IK06 EN 50102
- Ambient Air Temperature For Operation
- -25-70 °C
- Ambient Air Temperature For Storage
- -40-70 °C
- Standards
- EN/IEC 60947-5-1 || EN/IEC 60204-1 || EN 1088/ISO 14119 || CSA C22.2 No 14 || UL 508
- Electrical Shock Protection Class
- class I NF C 20-030 || class I EN/IEC 61140
- Safety Reliability Data
- B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
- Shock Resistance
- 50 gn 11 ms IEC 60068-2-27
- Vibration Resistance
- 25 gn 10-500 Hz)IEC 60068-2-6
- Protective Treatment
- TC
- Ip Degree Of Protection
- IP66 conforming to IEC 60529 || IP67 conforming to IEC 60529
- Safety Level
- can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508