Honeywell Industrial Automation Spare Parts

Honeywell logo

509 results

E34-4003200J04-SPKIT Honeywell, Power Supply
Honeywell

E34-4003200J04-SPKIT

CLASS 3400 SUBMETER, 1 or 2 Phase, 3200 A, 230/400 V AC

On Request

The Class 3400 Smart Meters (H34) incorporate advanced dual protocol communications, allowing for simultaneous interaction with up to two energy monitoring systems. These systems can include Building Automation Systems (BAS) for energy monitoring, billing programs, and Measurement & Verification (M&V) reporting tools. An optional feature package expands functionality with built-in load control and two pulse outputs for kWh and kVARh measurement.Equipped with a large 4-line LCD display that includes a backlight for enhanced visibility, the device supports RS485 and Ethernet communications. This fully electronic meter operates under rigorous standards, meeting ANSI C12.20 and UL/CUL regulatory approvals. With a maximum operating ambient temperature of 122 °F (50 °C) and a minimum of -4 °F (-20 °C), it is suitable for diverse commercial and industrial environments.The Class 3400 supports both single-phase and two-phase configurations, utilizing split-core current sensors that provide accurate readings within ±1% across the full load range. It is designed to monitor 3200 A with input voltage configurations of either 3 or 4 wire, and operates at frequencies of 50 Hz or 60 Hz, ensuring compatibility with a variety of electrical systems.

Available in:
US
Ask for a quote
E50-400800-J03-N-KIT Honeywell, Proximity & Inductive Sensors
Honeywell

E50-400800-J03-N-KIT

CLASS 5000 SUBMETER, 3 Phase, 800 A, 230/400 V AC

On Request

The Class 5000 Smart Meters (H50) are equipped with advanced dual protocol communications, allowing them to connect with up to two energy monitoring systems. These systems include building automation systems for energy monitoring and billing, as well as measurement and verification reporting tools. The device features a large 4-line LCD display with backlighting, ensuring easy readability of data.With an operating temperature range from -4 °F (-20 °C) to 122 °F (50 °C) and a maximum humidity of 95% non-condensing, this submeter is suitable for diverse commercial and industrial applications. The meter's construction conforms to regulatory approvals such as ANSI C12.20 and CE standards. The Class 5000 includes three split-core current sensors and operates on a frequency of 50 Hz or 60 Hz, providing accurate measurements within ±1% across the rated load range.For connectivity, it supports BACnet MS/TP and EZ-7 Ethernet communication protocols. The enclosure is made of JIC steel, ensuring durability and protection in various environments. The product's dimensions are 6.5 in (166 mm) in width, 7.8 in (198 mm) in height, and 3.4 in (86 mm) in depth, with a total weight of 12.26 lbs.

Available in:
US
Ask for a quote
HVFDSB3C0250G330/U Honeywell, VFDs & Frequency Converters
Honeywell

HVFDSB3C0250G330/U

VFD with Bypass and Disconnect, SmartVFD BYPASS, 480Vac, 25HP, Graphical, NEMA 3R Enclosure, Three Contactor Bypass

On Request

The variable frequency drive (VFD) with bypass functionalities is designed to optimize energy consumption in HVAC systems by controlling the speed of motors, particularly for fans and pumps. Operating at an input voltage of 460 (3PH) V AC and delivering a continuous output current capable of 38 A, this drive is particularly suited for applications requiring variable torque. Equipped with an intuitive graphical interface, the device simplifies commissioning with labor-saving features such as startup wizards and PC programming. The SmartVFD HVAC drive also supports internal PID control, allowing it to function effectively either in conjunction with a building automation system or autonomously. With a robust NEMA 3R enclosure, it is suitable for various environmental conditions, supporting ambient temperatures ranging from 14 °F to 104 °F and humidity levels up to 95%. The device incorporates three contactors for bypass operations and features a fused disconnect for added safety.

Ask for a quote
E10-2120200MSCS-NS Honeywell, Power Supply
Honeywell

E10-2120200MSCS-NS

CLASS 1000 SUBMETER - NO SENSORS, 1 Phase, 200 A, 120 V AC

On Request

The Class 1000 submeter (H10) is designed to accurately monitor electrical consumption in single-phase configurations, delivering kW and kWh data. This model, devoid of current sensors, ensures readings persist even during power interruptions. It is compatible with WEBs-AX Energy Analytics for tenant billing and E-mon Energy Software.With an operational current rating of 200 A and voltage of 120 V AC, this meter adheres to ANSI C12.20 and UL/CUL standards. Its construction features a compact enclosure measuring 6 in in width, 7.5 in in height, and 3 in in depth, while weighing 5.81 lbs. The device is built for a wide range of environmental conditions, functioning optimally between -4 °F (-20 °C) and 122 °F (50 °C) with a maximum humidity tolerance of 95% non-condensing.Accuracy is maintained at ±1% across a load range from 1% to 100%, ensuring reliable performance for commercial and industrial applications. The meter is equipped with a 2-line LCD display and operates under pulse output communication protocols, supporting 50 Hz and 60 Hz frequencies. This configuration enables effective monitoring without the inclusion of current sensors, relying on a solid-core type sensor approach.

Available in:
US
Ask for a quote
E50-12025HVR04-SPKIT Honeywell, Power Supply
Honeywell

E50-12025HVR04-SPKIT

CLASS 5000 SUBMETER, 1 or 2 Phase, 25 A, High Voltage (120) V AC

On Request

The Class 5000 Smart Meters are designed for advanced energy monitoring, featuring dual protocol communications that facilitate simultaneous connectivity with up to two energy monitoring systems. This capability includes integration with Building Automation Systems (BAS) for energy monitoring and billing applications, as well as Measurement and Verification (M&V) reporting tools.With a four-line LCD display that is backlit for enhanced visibility, the meter provides comprehensive data output. It supports RS485 and Ethernet communication protocols, ensuring versatile integration into existing infrastructures.This device is compliant with regulatory standards including CE and UL/CUL, and has dimensions of 6.5 inches in width, 7.8 inches in height, and 3.4 inches in depth, weighing 7.28 lbs. It operates within a temperature range of -4 °F to 122 °F and a humidity level of up to 95% non-condensing. The input voltage configuration can be set up for either 3 or 4 wire systems, and the device is capable of handling frequencies of 50 Hz or 60 Hz.Notably, the meter includes two split-core current sensors with an output of 2 V, ensuring accuracy within ±1% across the load spectrum from 1% to 100% of rated capacity. The enclosure is rated NEMA 4X, providing protection in various environments.

Available in:
US
Ask for a quote
E34-208100-R04-SPSCS-NS Honeywell, Proximity & Inductive Sensors
Honeywell

E34-208100-R04-SPSCS-NS

CLASS 3400 SUBMETER - NO SENSORS, 1 or 2 Phase, 100 A, 120/208-240 V AC

On Request

The Class 3400 Smart Meter (H34) is designed for advanced energy monitoring, featuring dual protocol communications that allow it to interface with up to two energy monitoring systems simultaneously. This includes integration with Building Automation Systems (BAS) for energy monitoring, billing, and Measurement & Verification (M&V) reporting tools.Equipped with a comprehensive feature set, the meter includes an optional package for load control and provides two pulse outputs for kWh and kVARh. Its advanced 4-line LCD display, complete with backlighting, enhances usability in various environments. Connectivity options include RS485 and Ethernet communications, making it suitable for diverse applications.With a regulatory compliance to ANSI C12.20 and UL/CUL standards, the meter operates across a voltage configuration of 120/208-240 V AC using either single-phase or two-phase setups. It supports a maximum current of 100 A and operates efficiently within a temperature range of -4 °F to 122 °F and maximum humidity levels of 95% non-condensing. The Class 3400 delivers accuracy within ±1% across a load range from 1% to 100% of its rated capacity, ensuring reliable measurements for commercial and industrial electrical usage.

Available in:
US
Ask for a quote
E34-2081600J01-X-KIT-NS Honeywell, Power Supply
Honeywell

E34-2081600J01-X-KIT-NS

CLASS 3400 SUBMETER - NO SENSORS, 3 Phase, 1600 A, 120/208-240 V AC

On Request

The CLASS 3400 (H34) Smart Meter facilitates dual protocol communications, permitting simultaneous interaction with up to two energy monitoring systems, which may include Building Automation Systems (BAS) for energy monitoring and billing or Measurement and Verification (M&V) reporting tools. The meter supports an optional expanded feature package that includes built-in load control capabilities and two pulse outputs for kWh and kVARh.Featuring an advanced 4-line LCD display with backlight, the meter is equipped with RS485 and Ethernet communication interfaces. The regulatory approvals for this device include ANSI C12.20 and UL/CUL certifications, ensuring compliance with industry standards.With dimensions of 6.5 inches in width, 7.8 inches in height, and 3.4 inches in depth, it is housed in a JIC steel enclosure. The CLASS 3400 operates effectively across a broad temperature range, from -4°F (-20°C) to a maximum of 122°F (50°C), and can withstand a maximum operating humidity of 95% non-condensing. This meter's accuracy is rated at ±1% from 1% to 100% of the rated load, making it suitable for precise electrical usage monitoring in commercial and industrial environments. It is designed to operate under either a 3 or 4 wire input voltage configuration with a frequency of 50/60 Hz.

Available in:
US
Ask for a quote
E50-600200-R03-SPKIT Honeywell, Proximity & Inductive Sensors
Honeywell

E50-600200-R03-SPKIT

CLASS 5000 SUBMETER, 1 or 2 Phase, 200 A, 347/600 V AC

On Request

The Class 5000 (H50) Smart Meter enables advanced dual protocol communications, facilitating simultaneous interaction with up to two energy monitoring systems, which may include BAS systems or billing programs. This model features a 4-line LCD display with backlight, providing clear visibility of metrics. It is equipped with RS485 and Ethernet communication capabilities.Constructed for both commercial and industrial settings, the meter is compliant with ANSI C12.20 standards and UL/CUL regulations. With an overall width of 6.5 inches (166 mm), height of 7.8 inches (198 mm), and depth of 3.4 inches (86 mm), it maintains a compact form factor. The device's enclosure is rated NEMA 4X, ensuring durability in various environmental conditions.Operational parameters include a minimum ambient temperature of -4 °F (-20 °C) and a maximum of 122 °F (50 °C), with a maximum humidity tolerance of 95% non-condensing. The Class 5000 meter features split-core current sensors and supports both single-phase and two-phase configurations. It operates on an input voltage configuration of 347/600 V AC, with a frequency range of 50 Hz to 60 Hz. The accuracy of the meter is ±1% across 1% to 100% of the rated load, making it suitable for detailed energy monitoring and reporting.

Available in:
US
Ask for a quote
E34-400800-J01KIT-NS Honeywell, General Accessories
Honeywell

E34-400800-J01KIT-NS

CLASS 3400 SUBMETER - NO SENSORS, 3 Phase, 800 A, 230/400 V AC

On Request

The CLASS 3400 (H34) Smart Meter is equipped with advanced dual protocol communications, facilitating simultaneous interaction with up to two energy monitoring systems. This includes compatibility with Building Automation Systems (BAS) for energy monitoring and billing, as well as Measurement and Verification (M&V) reporting tools. Additionally, an optional feature package is available, which offers integrated load control functions and two pulse outputs for kWh and kVARh.Featuring a sophisticated 4-line LCD display with backlight, the meter supports RS485 and Ethernet communications. It adheres to regulatory standards including ANSI C12.20 and UL/CUL. With dimensions of 6.5 in width, 7.8 in height, and 3.4 in depth, it is constructed with a JIC steel enclosure designed for durability in commercial and industrial settings.This model operates effectively within a temperature range of -20 °C to 50 °C and can manage ambient humidity levels of up to 95% non-condensing. The accuracy of the meter is rated at ±1% across 1% to 100% of the rated load, ensuring reliable electrical usage monitoring.

Available in:
US
Ask for a quote
HVFDSD3A0007G200A Honeywell, Power Supply
Honeywell

HVFDSD3A0007G200A

VFD Alone, SMARTVFD HVAC 208-240VAC 0.75HP NEMA12

On Request

The SMARTVFD HVAC is designed to optimize energy usage by adjusting the speed of motors in heating, ventilation, and air conditioning systems. With an input voltage of 208/230 (3-phase) V AC and rated at 0.75 HP, it effectively controls variable torque applications. The drive supports a continuous output current rating of 3.7 A and is equipped with both analog inputs and outputs, allowing for seamless integration into existing systems.This VFD features a NEMA 12 enclosure, ensuring protection against dust and moisture, making it suitable for various environments. It can operate under a wide range of temperatures, from a minimum of -10 °C (14 °F) to a maximum of 40 °C (104 °F) with a maximum operating humidity of 95%. Additionally, the device includes an EMC filter to minimize radio frequency interference, adhering to relevant regulatory approvals including CE and EN 61800-5-1.With a range of features that include startup wizards and PC programming capabilities, commissioning is streamlined for quick and accurate setup. The internal PID controls allow the VFD to function autonomously or in conjunction with a building automation system (BAS), enhancing overall system efficiency.

Available in:
US
Ask for a quote
E34-12025HVR07XSPKIT-NS Honeywell, Proximity & Inductive Sensors
Honeywell

E34-12025HVR07XSPKIT-NS

CLASS 3400 SUBMETER - NO SENSORS, 1 or 2 Phase, 25 A, High Voltage (120) V AC

On Request

The Class 3400 (H34) Smart Meters are engineered to facilitate advanced dual protocol communications, allowing for simultaneous interaction with two energy monitoring systems. This capability is instrumental for integrating with building automation systems (BAS) for energy monitoring, billing programs, and measurement and verification (M&V) reporting tools. An optional expanded feature package is available, which incorporates built-in load control functions and two pulse outputs for kWh and kVARh measurements.The device features a large 4-line LCD display with backlighting for enhanced visibility. Communication options include RS485 and Ethernet. With a regulatory approval of ANSI C12.20 and certification from UL/CUL, the meter measures 6.5 inches in width, 7.8 inches in height, and 3.4 inches in depth, weighing 7.34 pounds. The Class 3400 operates within a temperature range of -4 °F to 122 °F and a humidity level of up to 95% non-condensing. It employs a split-core current sensor output of 2 V, ensuring an accuracy of ±1% across 1% to 100% of the rated load.Designed for commercial and industrial applications, the Class 3400 is a fully electronic meter that utilizes popular communication protocols and provides 38 points of information for monitoring electrical usage. The input voltage configuration supports both 3 and 4 wire setups, and it operates at frequencies of 50 Hz and 60 Hz. The enclosure type is rated NEMA 4X, ensuring durability in various environments.

Available in:
US
Ask for a quote
E32-400200-JRTUSCS Honeywell, Proximity & Inductive Sensors
Honeywell

E32-400200-JRTUSCS

CLASS 3200 SUBMETER, 3 Phase, 200 A, 230/400 V AC

On Request

The Class 3200 Smart Meter (H32) is engineered for precise energy monitoring in industrial and commercial settings. It supports RS-485 communications, allowing integration with multiple energy monitoring systems, including building automation systems and billing programs. This model can communicate simultaneously with two systems, enhancing monitoring capabilities.With a three-phase configuration and a current rating of 200 A, the meter is suitable for a variety of applications. Its operational parameters include an input voltage of 230/400 V AC, a frequency range of 50 Hz to 60 Hz, and an accuracy rating of ±1% across the load spectrum. The device is equipped with three solid-core current sensors and features a 4-line LCD display with backlighting for clear readings.Designed to withstand a broad operating temperature range from -20 °C to 50 °C, the submeter has a maximum operating humidity of 95% non-condensing. It conforms to regulatory standards including ANSI C12.20 and UL/CUL, ensuring reliability and safety in operation. The enclosure type is JIC Steel, providing durability in various environments.

Available in:
US
Ask for a quote
E50-480100-R02KIT Honeywell, Proximity & Inductive Sensors
Honeywell

E50-480100-R02KIT

CLASS 5000 SUBMETER, 3 Phase, 100 A, 277/480 V AC

On Request

The Class 5000 (H50) Smart Meters are engineered for advanced energy monitoring, featuring dual protocol communications that facilitate simultaneous interaction with two distinct energy management systems. This includes options for building automation systems (BAS), energy monitoring, billing programs, and measurement and verification (M&V) reporting tools. Equipped with a 4-line LCD display, the meter supports RS485 and Ethernet communications, enhancing connectivity and data accessibility. The device operates within a temperature range of -4 °F to 122 °F (-20 °C to 50 °C) and maintains accuracy within ±1% across the load range from 1% to 100% of rated capacity. Its NEMA 4X enclosure ensures protection against environmental factors. With a current rating of 100 A and designed for 3 or 4 wire input voltage configurations, this meter also includes three split-core current sensors for precise monitoring. The Class 5000 is ideal for various commercial and industrial applications, providing 38 points of information for detailed electrical usage analysis, and complies with ANSI C12.20 and CE standards.

Available in:
US
Ask for a quote
E50-480100-J02NSPSCS Honeywell, Power Supply
Honeywell

E50-480100-J02NSPSCS

CLASS 5000 SUBMETER, 1 or 2 Phase, 100 A, 277/480 V AC

On Request

The CLASS 5000 (H50) Smart Meters facilitate advanced dual protocol communications, allowing for simultaneous interaction with up to two energy monitoring systems. This includes compatibility with BAS systems, energy monitoring, billing programs, and M&V reporting tools. The device features a 4-line LCD display with backlight for enhanced visibility.With an operating voltage configuration of 277/480 V AC and a current rating of 100 A, the submeter supports both single and dual-phase configurations. It operates effectively in ambient temperatures ranging from -4 °F (-20 °C) to 122 °F (50 °C), with a maximum humidity tolerance of 95% non-condensing. The Class 5000 meter complies with regulatory standards such as ANSI C12.20 and UL/CUL.It employs solid-core current sensors and provides accurate readings with a tolerance of ±1% across 1% to 100% of the rated load. The meter includes multiple communication protocols, including Modbus RTU and EZ-7 Ethernet, allowing for flexible integration into existing monitoring systems. The enclosure is constructed from JIC steel, ensuring durability and reliability in industrial environments.

Available in:
US
Ask for a quote
E34-480400-J05KIT-NS Honeywell, Power Supply
Honeywell

E34-480400-J05KIT-NS

CLASS 3400 SUBMETER - NO SENSORS, 3 Phase, 400 A, 277/480 V AC

On Request

The Class 3400 (H34) Smart Meter variant is engineered for advanced energy monitoring in commercial and industrial settings. It supports dual protocol communications, allowing integration with up to two energy monitoring systems simultaneously, including building automation systems and measurement and verification reporting tools. This model does not include current sensors and operates with a 3 or 4-wire input voltage configuration. The 4-line LCD display features backlighting for enhanced visibility, while communication is facilitated through RS485 and Ethernet interfaces. With an accuracy of ±1% across the rated load range, it effectively monitors electrical usage. The environmental specifications are noteworthy, with a minimum operating temperature of -4 °F (-20 °C) and a maximum threshold of 122 °F (50 °C), alongside a tolerable humidity level of up to 95% non-condensing. Regulatory approvals include ANSI C12.20 and UL/CUL certifications, ensuring compliance and reliability. The enclosure is constructed from JIC steel, contributing to its durability in diverse operational conditions.

Available in:
US
Ask for a quote
E50-400200-J04KIT-NS Honeywell, General Accessories
Honeywell

E50-400200-J04KIT-NS

CLASS 5000 SUBMETER - NO SENSORS, 3 Phase, 200 A, 230/400 V AC

On Request

The Class 5000 (H50) Smart Meter is engineered to support advanced dual protocol communications, allowing it to interface with two energy monitoring systems concurrently. This capability includes integration with building automation systems (BAS) for energy monitoring, billing programs, and measurement and verification (M&V) reporting tools.Featuring a large backlit 4-line LCD display, this meter facilitates ease of reading and monitoring. It supports both RS485 and Ethernet communications. With a current capacity of 200 A and operating voltage of 230/400 V AC, it is suitable for commercial and industrial applications.Regulatory approvals include CE and UL/CUL, ensuring compliance with industry standards. The unit measures 6.5 inches in width, 7.8 inches in height, and 3.4 inches in depth, weighing 5.1 pounds. It operates effectively within a temperature range of -4 °F to 122 °F and a humidity level of up to 95% non-condensing. The meter has an accuracy of ±1% across its rated load range, and it utilizes a split-core current sensor type.Designed specifically for three-phase applications, the Class 5000 is capable of monitoring various electrical metrics with 38 data points available for detailed analysis.

Available in:
US
Ask for a quote
E34-208100-J07XSPSCS Honeywell, Proximity & Inductive Sensors
Honeywell

E34-208100-J07XSPSCS

CLASS 3400 SUBMETER, 1 or 2 Phase, 100 A, 120/208-240 V AC

On Request

The Class 3400 Smart Meter (H34) integrates advanced dual protocol communications, allowing for simultaneous interaction with two distinct energy monitoring systems, which may include Building Automation Systems (BAS) and various billing or measurement and verification (M&V) tools. This model supports both 1 or 2 phase configurations and handles an input voltage of 120/208-240 V AC.Equipped with a 4-line LCD display and a range of connectivity options via RS485 and Ethernet, the meter can also be enhanced with an optional feature package that provides load control capabilities and two pulse outputs for kWh and kVARh tracking. The regulatory approvals include ANSI C12.20 and UL/CUL certifications.With a compact design measuring 6.5 in in width, 7.8 in in height, and 3.4 in in depth, the meter operates effectively in various environments, with an ambient temperature range of -4 °F to 122 °F and a maximum relative humidity of 95% non-condensing. The Class 3400 is optimized for commercial and industrial applications, ensuring accurate monitoring with a precision of ±1% across its operational load range.

Available in:
US
Ask for a quote
E32-208400-RRTUKIT-NS Honeywell, Power Supply
Honeywell

E32-208400-RRTUKIT-NS

CLASS 3200 SUBMETER - NO SENSORS, 3 Phase, 400 A, 120/208-240 V AC

On Request

The Class 3200 (H32) Smart Meter provides advanced energy monitoring capabilities through RS-485 communications. This model facilitates simultaneous communication with two energy monitoring systems, which may include building automation systems for energy usage tracking and billing, as well as measurement and verification reporting tools.This device is constructed with a NEMA 4X enclosure suitable for industrial environments, ensuring protection against dust and moisture. It operates within a temperature range of -4 °F to 122 °F and can withstand up to 95% non-condensing humidity. The Class 3200 meter features a 4-line LCD display with backlight for easy reading and is designed to support both 50 Hz and 60 Hz frequency operations.With an accuracy rating of ±1% across the full load range, this fully electronic meter is capable of monitoring electrical consumption effectively in commercial and industrial applications. The current sensor output is rated at 2 V, and the model operates on a three or four-wire input voltage configuration.

Available in:
US
Ask for a quote
E20-600400-R-D-KIT-NS Honeywell, Power Supply
Honeywell

E20-600400-R-D-KIT-NS

CLASS 2000 SUBMETER - NO SENSORS, 3 Phase, 400 A, 347/600 V AC

On Request

The Class 2000 (H20) submeter is engineered for three-phase power monitoring, providing essential kW and kWh information. This model does not include current sensors, making it suitable for setups that require external sensor integration. With a current rating of 400 A and a voltage configuration of 347/600 V AC, this submeter operates effectively within commercial and industrial environments. Regulatory compliance is assured with approvals including ANSI C12.20 and UL/CUL. The device features a compact design with overall dimensions of 6 inches in width, 7.5 inches in height, and 3 inches in depth, weighing approximately 5.1 lbs. It is capable of functioning in ambient temperatures ranging from -4 °F (-20 °C) to 122 °F (50 °C) and can withstand humidity levels up to 95% non-condensing. The Class 2000 submeter utilizes a 2-line LCD display for easy reading of measurements and communicates via pulse output. Its accuracy is rated at ±1% across the complete load range, ensuring reliable performance for energy monitoring applications.

Available in:
US
Ask for a quote
E50-480100-J08-SPKIT-NS Honeywell, Proximity & Inductive Sensors
Honeywell

E50-480100-J08-SPKIT-NS

CLASS 5000 SUBMETER - NO SENSORS, 1 or 2 Phase, 100 A, 277/480 V AC

On Request

The CLASS 5000 Smart Meters, identified by the designation code H50, incorporate advanced dual protocol communications. They facilitate concurrent communication with two energy monitoring systems, which may include Building Automation Systems (BAS) for energy monitoring, billing, or Measurement and Verification (M&V) reporting tools.This model features a 4-line LCD display with a backlight for improved visibility. Connectivity options include RS485 and Ethernet, accommodating diverse communication protocols such as LonWorks TP/FT-10 and Modbus TCP/IP.With an operating temperature range from -4 °F (-20 °C) to 122 °F (50 °C) and a maximum humidity of 95% non-condensing, this meter is suitable for various commercial and industrial settings. The meter's accuracy is ±1% across 1% to 100% of its rated load, ensuring reliable performance.It is housed in a JIC steel enclosure, measuring 6.5 inches in width, 7.8 inches in height, and 3.4 inches in depth, with a total weight of 5.1 lbs. The device operates on a 3 or 4 wire input voltage configuration at frequencies of either 50 Hz or 60 Hz.

Available in:
US
Ask for a quote