Fluke

124B

1 / 4
thumbnail
thumbnail
thumbnail
thumbnail
Part Number
124B
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Meter Readings

Record Size (min, max, average)
2 M readings for 1 channel
Maximum number of events
1024
Measurement Speed
Maximum 2 measurement/s
Recorded Time Span
2 weeks

Power (125B only)

Full scale reading
999 counts
Watt
RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes)
VA
Vrms x Arms
Full scale reading
999 counts
Configurations
1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)
Full scale reading
999 counts
VA reactive (var)
√((VA)2-W2)
Power factor (PF)
Ratio between watts and VA range - 0.00 to 1.00

Crest factor (CREST)

Full scale reading
90 Counts
Range
1 to 10

Waveform Record

Recorded Time Span SD card
11 hours at 500 μs/div 14 days at 20 ms/div
Size Internal memory
400 M samples Recorded Time
Record Size SD card
1.5 G samples
Maximum number of events
64
Maximum sample rate
400 K sample/s
Span internal memory
15 minutes at 500 μs/div 11 hours at 20 ms/div

Decibel (dB)

0 dBV
1 V
0 dBm (600 Ω /50 Ω)
1 mW referenced to 600 Ω or 50 Ω
Full scale reading
1000 counts
DB on
V dc, V ac, or Vac+dc

Advanced Meter Functions

Fixed decimal point
Activated by using attenuation keys
AutoHold (on A)
Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.
Zero Set
Set actual value to reference

Pulse width (PULSE)

Full scale reading
1000 counts
Frequency range
15 Hz (1 Hz) to 30 MHz in continuous autoset

Input A and Input B

Full scale reading
5000 counts
Common mode rejection (CMRR)
>100 dB @ dc, >60 dB @ 50, 60, or 400 Hz
Accuracy
±(0.5% +5 counts)
Ranges
500 mV, 5 V, 50 V, 500 V, 750 V

Phase

Modes
A to B, B to A
Resolution
1 degree
Range
0 to 359 degrees

Continuity (Cont)

Beep
<(30 Ω ±5 Ω) in 50 Ω range
Measurement current
0.5 mA
Detection of shorts of
≥1 ms

Capacitance (CAP)

Full scale reading
5000 counts
Measurement current
500 nA to 0.5 mA, increases with increasing ranges
Ranges
50 nF, 500 nF, 5 μF, 50 μF, 500 μF

Frequency (Hz)

Frequency range
15 Hz (1 Hz) to 50 MHz in continuous autoset
Accuracy @1 Hz to 1 MHz
±(0.5% +2 counts)
Ranges
124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz
Ranges
123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz
Full scale reading
10,000 counts

Cursor Readout (124B and 125B)

Rise or fall time
Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only  possible in single channel mode)
Single vertical line
Min, max and time from start of readout (in RECORDER mode; instrument in HOLD)
Single vertical line
Average, min and max readout
Sources
A, B
Single vertical line
Harmonics values in POWER QUALITY mode.
Single vertical line
Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD)
Dual vertical lines
Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)
Dual horizontal lines
High, low and peak-peak readout
Accuracy
As oscilloscope accuracy
Dual vertical lines
Peak-peak, time distance and reciprocal time distance readout

RPM

Accuracy
±(0.5% +2 counts)
Max reading
50.00 kRPM

Duty cycle (PULSE)

Range
2% to 98%
Frequency range
15 Hz (1 Hz) to 30 MHz in continuous autoset

Temperature (TEMP) with optional temperature probe

Accuracy
As V dc (add temp. probe uncertainty)
Range
200 °C/div (200 °F/div)
Scale factor
1 mV/°C and 1 mV/°F

Vpwm

Purpose
To measure on pulse width modulated signals, like motor drive inverter outputs
Principle
Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
Accuracy
As Vrms for sinewave signals