Fluke

190-104

1 / 4
thumbnail
thumbnail
thumbnail
thumbnail
Part Number
190-104
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Mechanical and General Specifications

Size
270 x 190 x 70 mm
Li-Ion battery
BP291 4800 mAh battery up to 7 Hours included standard
Warranty
3-years on main instrument, 1-year on accessories
Weight
2.2 kg

Included Accessories

Warranty
Three years on main instrument, one year on accessories

Specifications

Independently floating isolated inputs
Up to 1000 V CAT III/600 V CAT IV between inputs, references and ground
Scope measurements
Automatic: 30
Waveform compare
Waveform reference with automatic Pass/Fail testing
Trigger types
Connect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle
Real-time sample rate
1.25 GS/s
Bandwidth
100 MHz
Inputs
4scope plus DMM input
Timebase range
G5 ns - 2 min/div
Maximum record length
ScopeRecord mode: 30,000 pts
Glitch capture
8 ns
Maximum record length
Scope mode: 10,000 pts per input
Input sensitivity
2 mV-100 V/div
Scope measurements
Cursor: 7
Number of channels
100MHz: 4 channels
Trigger source
Any scope input channel, or external via DMM
Persistence
Digital persistence giving analog oscilloscope-like waveform decay

Safety Specifications

Electrical safety
1,000 V CAT III/600V CAT IV (EN61010-1)

Environmental Specifications

Operating temperature
0°C to 40°C Including Batteries
Operating temperature
0°C to 50°C Excluding Batteries
Operating altitude
Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Operating altitude
Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
Storage temperature
-20°C to +60°C