Fluke

279 FC TRMS

1 / 4
thumbnail
thumbnail
thumbnail
thumbnail
Part Number
279 FC TRMS
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

DMM

Continuity with beeper
Yes
Resistance
50 MΩ
Diode test
Yes
Basic dc accuracy
0.09%
Current ac
iFlex Flexible Current Probe (included with the 279 FC/iFlex)
Bandwidth
1% 45 Hz to 65 Hz, full time low pass filter
Min/Max recording
Yes
Capacitance
9,999 µF
Display Hold
Yes
Voltage
ac/dc 1000 V
Frequency
100 kHz

General specifications

Wireless frequency
2.4 GHz ISM Band, 20 meter range
Operating temperature
-10 °C to 50 °C (14 °F to 122 °F)
Altitude
2,000 meters (6,561 feet)
Warranty
Limited three-year warranty
Relative humidity
0% to 90% (0 °C to 35 °C) (32 °F to 95 °F) 0% to 75% (35 °C to 40 °C) (95 °F to 104 °F) 0% to 45% (40 °C to 50 °C) (104 °F to 122 °F)
Certifications
CE, CSA, FCC
Ingress Protection
(IP) IP40 (non-operating)
Size
215.9 x 93.9 x 57.1 mm (8.5 x 3.7 x 2.25 in)
Weight
0.793 kg (1.75 lb)
Temperature coefficient
Add 0.1 x specified accuracy for each °C above 28 °C or below 18 °C (°F above 82 °F or below 64° F)
Safety compliance
IEC 61010-1: Pollution degree 2; IEC 61010-2-033: CAT III 1000 V/CAT IV 600 V
EMC
EN 61326-1:2012
Battery type
Rechargeable lithium ion battery (charge time: 4.5 hours)
Storage temperature
-20 ºC to 60 ºC (-4 °F to 140 °F)

Infrared Camera

Center point
Yes (with center point temp)
Memory storage
Approximately 100 images (internal)
Background compensation
20 °C fixed
Infrared resolution
80 x 60
File format
Non-radiometric .is2
Emissivity
0.95 fixed
Focus mechanism
Fixed focus
Temperature Range (selectable °C and °F)
-10 °C to 200 °C (14 °F to 392 °F) Accuracy: ±5 °C (41 °F) or (±5% as tested)
Field of View
36° (w) x 27° (h)
NETD
≤200 mK
Infrared spectral band
7.5 to 14 microns
Image capture frequency
8 Hz