Fluke
572-2
1 / 2
- Part Number
- 572-2
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 19 pcs.In-StockUpdated at: 21-11-2024
- Warranty:
- 12 months
- Estimated Delivery:
- On Request
- Condition:
- New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Measurement Options
- Probe input
- K-type thermocouple simultaneous display of probe and IR temperature
- Hi/Low alarms
- Audible and two-color visual
- Display
- Dot matrix 98 x 96 pixels with function menus
- Data storage
- 99 points
- Switchable celsius and fahrenheit
- Yes
- Min/Max/Avg/Dif
- Yes
- Trigger lock
- Yes
- Communication
- USB 2.0
- Backlight
- Two levels, normal and extra bright for darker environments
K-Type Thermocouple Specifications
- Cable length
- 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination
- Accuracy
- ±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)
- Measurement range (bead probe)
- -40°C to 260°C (-40°F to 500°F)
Infrared Measurements
- Infrared temperature range
- -30°C to 900°C (-22°F to 1652°F)
- Emissivity
- Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
- IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)
- ≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater
- IR repeatability
- ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
- IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)
- ≥ -10°C to < 0°C: ±2°C
- Minimum spot size
- 19 mm
- IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)
- < -10°C: ±3°C
- Laser sighting
- Offset dual laser, output < 1 mW
- Response time (95%)
- < 500 ms
- IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)
- < 14°F: ±6°F
- IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)
- ≥ 14°F to < 32°F: ±4°F
- Display resolution
- 0.1°C / 0.1°F
- IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)
- ≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater
- Distance: Spot
- 60:1 (calculated at 90% energy)
- Spectral response
- 8 μm to 14 μm
Contact Measurements
- K-type thermocouple repeatability
- ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
- K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C)
- ≥ -40°C: ±1% or 1°C, whichever is greater
- K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C)
- < -40°C: ±(1°C + 0.2° / 1°C)
- K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C)
- ≥ -40°F: ±1% or 2°F, whichever is greater
- K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C)
- < -40°F: ±(2°F + 0.2° / 1°F)
- K-type thermocouple input temperature range
- -270°C to 1372°C (-454°F to 2501°F)
- K-type thermocouple
- 0.1°C / 0.1°F
General Specifications
- Storage temperature
- -20°C to 60°C (-4°F to 140°F)
- Safety and compliance
- IEC 60825-1 FDA Laser Class II IEC 61326-1 CE Complaint CMC # 01120009
- Battery life
- 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on)
- Operating temperature
- 0°C to 50°C (32°F to 122°F)
- Power
- 2 AA batteries
- Relative humidity
- 10% to 90% RH non-condensing up to 30°C (86°F)
- Weight
- 0.322 kg (0.7099 lb)
- Operating altitude
- 2000 meters above mean sea level
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther