Fluke

572-2

1 / 2
thumbnail
thumbnail
Part Number
572-2
Payment methods:
Best offer from:
USTrusted Automa.Net Supplier
Availability:
19 pcs.
In-Stock
Updated at: 21-11-2024
Warranty:
12 months
Estimated Delivery:
On Request
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies

Measurement Options

Probe input
K-type thermocouple simultaneous display of probe and IR temperature
Hi/Low alarms
Audible and two-color visual
Display
Dot matrix 98 x 96 pixels with function menus
Data storage
99 points
Switchable celsius and fahrenheit
Yes
Min/Max/Avg/Dif
Yes
Trigger lock
Yes
Communication
USB 2.0
Backlight
Two levels, normal and extra bright for darker environments

K-Type Thermocouple Specifications

Cable length
1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination
Accuracy
±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)
Measurement range (bead probe)
-40°C to 260°C (-40°F to 500°F)

Infrared Measurements

Infrared temperature range
-30°C to 900°C (-22°F to 1652°F)
Emissivity
Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)
≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater
IR repeatability
±0.5% of reading or ±0.5°C (±1°F), whichever is greater
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)
≥ -10°C to < 0°C: ±2°C
Minimum spot size
19 mm
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)
< -10°C: ±3°C
Laser sighting
Offset dual laser, output < 1 mW
Response time (95%)
< 500 ms
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)
< 14°F: ±6°F
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)
≥ 14°F to < 32°F: ±4°F
Display resolution
0.1°C / 0.1°F
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)
≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater
Distance: Spot
60:1 (calculated at 90% energy)
Spectral response
8 μm to 14 μm

Contact Measurements

K-type thermocouple repeatability
±0.5% of reading or ±0.5°C (±1°F), whichever is greater
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C)
≥ -40°C: ±1% or 1°C, whichever is greater
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C)
< -40°C: ±(1°C + 0.2° / 1°C)
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C)
≥ -40°F: ±1% or 2°F, whichever is greater
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C)
< -40°F: ±(2°F + 0.2° / 1°F)
K-type thermocouple input temperature range
-270°C to 1372°C (-454°F to 2501°F)
K-type thermocouple
0.1°C / 0.1°F

General Specifications

Storage temperature
-20°C to 60°C (-4°F to 140°F)
Safety and compliance
IEC 60825-1 FDA Laser Class II IEC 61326-1 CE Complaint CMC # 01120009
Battery life
8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on)
Operating temperature
0°C to 50°C (32°F to 122°F)
Power
2 AA batteries
Relative humidity
10% to 90% RH non-condensing up to 30°C (86°F)
Weight
0.322 kg (0.7099 lb)
Operating altitude
2000 meters above mean sea level