P specifications
- Reference probe connection
- 6-pin Din with Infocon Technology
- RTD resistance accuracy‡
- 0 ohms to 25 ohms: ±0.002 ohms 25 ohms to 400 ohms: ±80 ppm of reading
- Loop power function
- 24 V DC loop power
- TC millivolt range
- –10 mV to 75 mV
- Internal cold junction compensation accuracy
- ±0.35°C (ambient of 13°C to 33°C)
- Voltage accuracy
- 0.025% of reading + 0.01 mV
- RTD measurement capability
- 4-wire RTD (2-,3-wire RTD w\ Jumpers only)
- MA range
- Cal 4-22 mA, Spec 4-24 mA
- Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
- 1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires.
- TC connection
- Small connectors
- Reference resistance range
- 0 ohms to 400 ohms
- MA connection
- 2 terminal input
- Built-in RTD thermometer readout accuracy
- NI-120: ±0.015°C at 0°C PT-100 (385): ±0.02°C at 0°C PT-100 (3926): ±0.02°C at 0°C PT-100 (JIS): ±0.02°C at 0°C
- Built-in mA readout accuracy
- 0.02% of reading + 2 mV
- Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
- ±0.005% of range per °C
- Built-in reference thermometer readout accuracy (4-Wire reference probe)1
- ±0.010°C at -25°C ±0.015°C at 0°C ±0.020°C at 50°C ±0.025°C at 150°C ±0.030°C at 200°C ±0.040°C at 350°C ±0.050°C at 420°C ±0.070°C at 660°C
- Reference characterizations
- ITS-90, CVD, IEC-751, Resistance
- RTD characterizations
- PT-100 (385),(JIS),(3926), NI-120, Resistance
- Reference measurement capability
- 4-wire
- Reference resistance accuracy2
- 0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading
- Built-in TC thermometer readout accuracy
- Type J: ±0.7°C at 660°C Type K: ±0.8°C at 660°C Type T: ±0.8°C at 400°C Type E: ±0.7°C at 660°C Type R: ±1.4°C at 660°C Type S: ±1.5°C at 660°C Type M: ±1.4°C at 660°C Type L: ±0.7°C at 660°C Type U: ±0.75°C at 600°C Type N: ±0.9°C at 660°C Type C: ±1.1°C at 660°C
- RTD resistance range
- 0 ohms to 400 ohms
- RTD connection
- 4 terminal input
Base Unit Specifications
- Cooling time
- 32 min: 350°C to 33°C 14 min: 350°C to 100°C
- Computer interface
- RS-232 and 9930 Interface-it control software included
- Immersion (well) depth
- 150 mm (5.9 in)
- Power requirements
- 100 V to 115 V (±10%), 50/60 Hz, 1400 W 230 V (±10%), 50/60 Hz, 1800 W
- Radial uniformity
- ±0.01°C at 33°C ±0.015°C at 200°C±0.02°C at 350°C
- Stability
- ±0.02°C at 33°C ±0.02°C at 200°C±0.03°C at 350°C
- Display
- LCD, °C or °F user-selectable
- Heating time
- 5 min: 33°C to 350°C
- Hysteresis
- 0.03
- Display accuracy
- ±0.2°C Full Range
- Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes)
- ±0.015°C Full Range
- Insert OD
- 25.3 mm (1.00 in)
- Axial uniformity at 40 mm (1.6 in)
- ±0.04°C at 33°C ±0.1°C at 200°C±0.2°C at 350°C
- Temperature range at 23°C
- 33°C to 350°C (91°F to 662°F)
- Resolution
- 0.01°
- Environmental conditions (for all specifications except temperature range)
- 13°C to 33°C
- Weight
- 7.3 kg (16 lb)
- Size (H x W x D)
- 290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
- Operating conditions
- 0°C to 50°C, 0% to 90% RH (non-condensing)
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther