Fluke
9190A-C
1 / 4
- Part Number
- 9190A-C
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
P Specifications
- Reference resistance range
- 0 Ω to 400 Ω
- Built-in TC thermometer readout accuracy5
- Type K: ±0.75°C at 140°C
- Built-in reference thermometer readout accuracy (4-wire reference probe)3
- ±0.020°C at 50°C
- Built-in RTD thermometer readout accuracy
- PT-100 (3926): ±0.02°C at 0°C
- Loop power function
- 24 V DC loop power
- Built-in RTD thermometer readout accuracy
- PT-100 (385): ±0.02°C at 0°C
- RTD resistance range
- 0 Ω to 400 Ω
- MA connection
- 2 terminal input
- Built-in TC thermometer readout accuracy5
- Type T: ±0.60°C at 140°C
- MA range
- Cal 4-22 mA, Spec 4-24 mA
- Built-in TC thermometer readout accuracy5
- Type S: ±1.60°C at 140°C
- Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
- ±0.005% of range per °C
- Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C)
- 1. For ambient temperature of 23°C. 2. Time from when the SETPOINT is reached to when the unit is with in stability specification. 3. The temperature range may be limited by the reference probe connected to the readout. The built-in reference accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 4. Measurement accuracy specifications apply within the operating range and assume 4 wires for PRTs. With 3-wire RTDs add 0.05 Ω to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires. 5. The thermocouple input readout is sensitive to EM fields in the frequency range of 500 MHz to 700 MHz.
- Reference probe connection
- 6-pin din with INFO-CON technology
- RTD measurement capability
- 2-wire, 3-wire, and 4-wire RTD with jumpers only
- Voltage accuracy
- 0.025% of reading +0.01 mV
- TC connection
- Miniature connectors (ASTM E1684)
- Built-in TC thermometer readout accuracy5
- Type E: ±0.60°C at 140°C
- Built-in reference thermometer readout accuracy (4-wire reference probe)3
- ±0.015°C at 0°C
- Reference resistance accuracy4
- 0 Ω to 42 Ω: ±0.0025 Ω 42 Ω to 400 Ω: ±60 ppm of reading
- Built-in RTD thermometer readout accuracy
- PT-100 (JIS): ±0.02°C at 0°C
- Built-in TC thermometer readout accuracy5
- Type M: ±0.65°C at 140°C
- Built-in TC thermometer readout accuracy5
- Type R: ±1.60°C at 140°C
- Built-in reference thermometer readout accuracy (4-wire reference probe)3
- ±0.010°C at –95°C
- Built-in reference thermometer readout accuracy (4-wire reference probe)3
- ±0.013°C at –25°C
- RTD characterizations
- PT-100 (385), (JIS), (3926), NI-120, resistance
- Built-in mA readout accuracy
- 0.02% of reading + 0.002 mA
- Built-in TC thermometer readout accuracy5
- Type N: ±0.75°C at 140°C
- Reference measurement capability
- 4 wire
- Resistance accuracy4
- 0 Ω to 25 Ω: ±0.002 Ω
- Built-in TC thermometer readout accuracy5
- Type L: ±0.65°C at 140°C
- Built-in RTD thermometer readout accuracy
- NI-120: ±0.015°C at 0°C
- RTD connection
- 4-terminal input
- Built-in TC thermometer readout accuracy5
- Type J: ±0.70°C at 140°C
- Built-in TC thermometer readout accuracy5
- Type U: ±0.70°C at 140°C
- Reference characterizations
- ITS-90, CVD, IEC-751, resistance
- Built-in reference thermometer readout accuracy (4-wire reference probe)3
- ±0.025°C at 140°C
- Resistance accuracy4
- 25 Ω to 400 Ω: ±80 ppm of reading
- TC millivolt range
- –10 mV to 75 mV
- Internal cold junction compensation accuracy
- ±0.35°C (ambient of 13°C to 33°C)
- Built-in TC thermometer readout accuracy5
- Type C: ±1.00°C at 140°C
Specifications
- Axial uniformity at 40 mm (1.6 in)
- ±0.05°C full range
- Operating conditions
- RH (non-condensing) < 2000 m altitude
- Environmental conditions for all specifications except temperature range
- 13°C to 33°C
- Immersion (well) depth
- 160 mm (6.3 in)
- Loading effect
- (with a 6.35 mm reference probe and three 6.35 mm probes)
- Refrigerants
- R704 (Helium)
- Cooling time1
- 23°C to –95°C: 90 min
- Resolution
- 0.01°
- Heating time1
- –95°C to 140°C: 40 min
- Loading effect
- (versus display with one 6.35 mm probe)
- Stabilization time2
- 15 min
- Well diameter
- 30 mm (1.18 in)
- Power requirements
- 200 V to 230 V (±10%) 50/60 Hz, 575 W
- 4–20 mA fuse (-P model only)
- 50 mA F 250 V
- Refrigerants
- < 20 g, ASHRAE safety group A2L
- Display accuracy
- ±0.2°C full range
- Electromagnetic environment
- IEC 61326-1: Basic
- Safety
- IEC 61010-1, Installation Category II, Pollution degree 2
- Loading effect
- ±0.25°C at –95°C
- Loading effect
- ±0.10°C at 140°C
- Refrigerants
- < 20 g, ASHRAE safety group A1
- Temperature range at 23°C
- –95°C to 140°C (–139°F to 284°F)
- Weight
- 16 kg (35 lb)
- Refrigerants
- R32 (Difluoromethane)
- Display
- LCD, °C or °F user selectable
- System fuse ratings
- 230 V: 3.15 A T 250 V
- Cooling time1
- 23°C to –90°C: 80 min
- Size (H x W x D)
- 480 x 205 x 380 mm (18.8 x 8.0 x 14.9 in)
- Radial gradient
- ±0.01°C full range
- Operating conditions
- 0°C to 35°C, 0% to 90%
- System fuse ratings
- 115 V: 6.3 A T 250 V
- Stability
- ±0.015°C full range
- Loading effect
- ±0.006°C full range
- Computer interface
- RS-232, USB Serial, and 9930 interface-it temperature calibration software included
- Power requirements
- 100 V to 115 V (±10%) 50/60 Hz, 575 W
- Cooling time1
- 140°C to 23°C: 60 min
- Accuracy with external reference3
- ±0.05°C full range
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther