Fluke
FLK-1663
1 / 2
- Part Number
- FLK-1663
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Continuity testing (RLO)
- Range (autoranging)
- 20 Ω / 200 Ω / 2000 Ω
- Resolution
- 0.01 Ω / 0.1 Ω / 1 Ω
- Open Circuit Voltage
- >4 V
Tripping speed test (ΔT)
- Current settings¹
- 10-30-100-300-500-1000 mA – VAR10-30-100 mA
- Multiplier
- x 1/2, x 1x 5
- Measurement range RCD Type G
- 310 ms50 ms
- Measurement range RCD Type S
- 510 ms160 ms
- Notes
- ¹1000 mA type AC only700 mA maximum type A in VAR modeVAR mode not available for type B. || ¹30% to 150% for Type A IΔN > 10 mA30% to 210% for Type A IΔN = 10 mA20% to 210% for Type B
- Current range
- 30% to 110% of RCD rated current¹
- Step size
- 10% of IΔN²
- Dwell time Type G
- 300 ms/step
- Dwell time Type S
- 500 ms/step
- Measurement accuracy
- ±5%
- Specified trip current ranges (EN 61008-1)
- 50% to 100% for Type AC35% to 140% for Type A (>10 mA)35% to 200% for Type A (≤10 mA)50% to 200% for Type B²5% for Type B
RCD testing, RCD types tested
- RCD Type
- AC¹G²,S³
- Model 1663
- A4, AC¹, G²,S³
- Notes
- ¹Responds to AC²General, no delay³Time delay4Responds to pulsed signal5Responds to smooth DC signal
Insulation resistance measurement (RISO)
- Test voltages
- 50-100-250-500-1000 V
- Accuracy of tTest voltage (at rated test current)
- +10%, -0%
- Test voltage
- 50 V100 V250 V500 V1000 V
- Insulation resistance range
- 20 MΩ /50 MΩ20 MΩ / 100 MΩ20 MΩ / 200 MΩ20 MΩ / 200 MΩ / 500 MΩ20 MΩ / 200 MΩ / 1000 MΩ
- Resolution
- 0.01 MΩ / 0.1 MΩ0.01 MΩ / 0.1 MΩ0.01 MΩ / 0.1 MΩ0.01 MΩ / 0.1 MΩ / 1 MΩ0.01 MΩ / 0.1 MΩ / 1 MΩ
- Test current
- 1 mA @ 50 kΩ1 mA @ 100 kΩ1 mA @ 250 kΩ1 mA @ 500 kΩ1 mA @ 1 MΩ
Phase Sequence Indication
- Icon
- Phase Sequence indicator is active.
AC voltage measurement
- Range
- 500 V
- Resolution
- 0.1 V
- Accuracy 45 Hz – 66 Hz
- 0.8% + 3
- Input impedance
- 360 kΩ
- Overload protection
- 660 V rms
Loop and line impedance (ZI)
- Range
- 10 Ω / 0.001 Ω / High current mΩ mode || 1000 A / 10 kA (50 kA)
- Resolution
- 0.01 Ω / 0.1 Ω / 1 Ω || 1 A / 0.1 kA
- Computation
- Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
Earth Resistance Test (RE)
- Range
- 200 Ω / 2000 Ω
- Resolution
- 0.1 Ω / 1Ω
- Frequency
- 128 Hz
- Output Voltage
- 25 V
General Specifications
- Size (L x W x H)
- 10 x 25 x 12.5 cm
- Weight (incl. batteries)
- 1.3 Kg
- Battery size, quantity
- Type AA, 6 ea.
- Sealing
- IP-40
- Safety
- Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition
- Overvoltage
- CAT III / 500V; CAT IV 300V
- Performance
- EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther