- Range
- 0.5 A to 400.0 A
- Resolution
- 0.1 A
- Accuracy
- 400.0 A: 2% ± 5 digits (10 Hz to 100 Hz), 2.5% ± 5 digits (100 Hz to 500 Hz)
- Inrush
- Max displayed reading: 999.9A
- Crest factor (50 Hz/60 Hz)
- 3 at 500 A2.5 at 600 A1.42 at 1000 AAdd 2 % for C.F. > 2
- LCD w/backlight
- 3 1/2 digits
- Log rate/interval
- 1 sec minimum/adjustable by PC
- Battery type
- 2 AA, NEDA 15 A, IEC LR6
- Battery life
- 400 hours
- Memory
- Record up to 65,000 readings
- RF communications
- 2.4 GHZ ISM Band
- RF communication range Open air, unobstructed
- Up to 20 m
- RF communication range Obstructed, sheetrock wall
- Up to 6.5 m
- RF communication range Obstructed, concrete wall or steel electrical enclosure
- Up to 3.5 m
- Operating temperature
- -10°C to +50°C
- Storage temperature
- -40°C to +60°C
- Temperature coefficient
- Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
- Operating humidity
- 90% at 35°C75% at 40°C45% at 50°C
- Altitude
- Operating: 2,000 m
- Altitude Storage
- 12,000 m
- EMC
- EN 61326-1:2006
- Safety compliance
- IEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2
- Safety rating
- CAT III 600 V
- Certifications
- CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
- Ingress Protection (IP) rating
- IP30
- Pollution Degree
- 2
- Jaw opening
- 34 mm (1.33 in)
- Size (HxWxD)
- 20.3 cm x 7.49 cm x 3.55 cm (8 in x 2.95 in x 1.4 in)
- Weight
- .22 kg (8 oz)
- Warranty
- Three years