Fluke
FLK-Ti450 9 Hz
1 / 4
- Part Number
- FLK-Ti450 9 Hz
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Data storage and image capture
- Video recording
- Standard and radiometric
- File formats video
- Non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3)
- Image file formats
- Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files
- Extensive memory options
- Removable 4 GB micro SD memory card, 4 GB internal flash memory, save to USB flash drive capability, upload to Fluke Cloud™ for permanent storage
- Remote control operation
- Yes, through SmartView® software or Fluke Connect® mobile app
- Software
- SmartView® software - full analysis and reporting software and Fluke Connect® system
- Memory review
- Thumbnail and fullscreen review
- Image capture, review, save mechanism
- One-handed image capture,review, and save capability
- Export file formats with SmartView® software
- Bitmap (.bmp), GIF, JPEG, PNG, TIFF
- Voice annotation
- 60 seconds maximum recording time per image; reviewable playback on camera, optional bluetooth headset available but not required
- Text annotation
- Yes
- Streaming video (remote display)
- Yes, see the live stream of the camera display on your PC, smartphone, or TV monitor. Via USB, WiFi hotspot, or WiFi network to SmartView® software on a PC; via WiFi hotspot to the Fluke Connect® app on a smartphone; or via HDMI to a TV monitor
- Auto capture (temperature and interval)
- Yes
- IR-PhotoNotes™
- Yes (5 images)
Wireless connectivity
- Fluke Connect® Assets optional software
- Yes, assign images to assets and create work orders. Easily compare measurement types - whether mechanical, electrical or infrared images - in one location.
- Fluke Connect® tool compatible
- Yes, connects wirelessly to select Fluke Connect® enabled tools and displays measurements on camera screen. Five simultaneous connections supported.
- Fluke Connect® Instant Upload
- Yes, connect your camera to your building's WiFi network, and images taken automatically upload to the Fluke Connect® system for viewing on your smartphone or PC
- Fluke Connect® app compatible
- Yes, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect® app for saving and sharing
Key Features
- Laser distance meter
- Yes, calculates distance to the target for precisely focused images and displays distance on screen
- Detector resolution
- 320 x 240 (76,800 pixels) — or 640 x 480 with SuperResolution
- Ruggedized touchscreen display
- 3.5 inch (landscape) 640 x 480 LCD
- Digital zoom
- 2x and 4x
- Rugged, ergonomic design for one-handed use
- Yes
- LaserSharp® Auto Focus
- Yes, for consistently in-focus images. Every. Single. Time.
- MultiSharp™ Focus
- Yes, focused near and far, throughout the field of view
- Advanced manual focus
- Yes
- SuperResolution
- Yes, on camera and in software. Captures and combines 4x the data to create a 640 x 480 image
- IFOV with standard lens (spatial resolution)
- 1.31 mRad, D:S 753:1
Battery
- AC operation
- AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz)
- Battery life
- 3-4 hours per battery (*Actual life varies depending on settings and usage)
- Batteries (field-replaceable, rechargeable)
- Two lithium ion smart battery packs with five-segment LED display to show charge level
- Battery charge time
- 2.5 hours to full charge
- Power saving
- User selectable sleep and power off modes
- Battery charging system
- Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter
Level and Span
- Fast auto toggle between manual and auto modes
- Yes
- Fast auto-rescale in manual mode
- Yes
- Minimum span (in auto mode)
- 3.0 °C (5.4 °F)
- Minimum span (in manual mode)
- 2.0 °C (3.6 °F)
Temperature measurement
- On-screen transmission correction
- Yes
- On-screen emissivity correction
- Yes (both value and table)
- Thermal sensitivity (NETD)
- ≤0.05 °C at 30 °C target temp (50 mK)
- Filter mode (NETD improvement)
- ≤0.03 °C at 30 °C target temp (30 mK)
- Accuracy
- ±2 °C or 2% (at 25 °C nominal, whichever is greater)
- On-screen reflected background temperature compensation
- Yes
- Temperature measurement range (not calibrated below -10 °C)
- -20 °C to +1200 °C (-4 °F to +2192 °F)
Color palettes
- Warranty
- Two-years (standard), extended warranties are available
- User-definable spot markers
- 3 user-definable spot markers
- Storage temperature
- -20 °C to +50 °C (-4 °F to 122 °F) without batteries
- Center-point temperature measurement
- Yes
- Ultra Contrast™ palettes
- General specifications
- Infrared spectral band
- 7.5 μm to 14 μm (long wave)
- LED light (torch)
- Yes
- Size (H x W x L)
- 27.7 x 12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in)
- Recommended calibration cycle
- Two-years (assumes normal operation and normal aging)
- Ultra Contrast™ palettes
- 8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra
- Spot temperature
- Hot and cold spot markers
- Drop
- Engineered to withstand 2 meter (6.5 feet) drop with standard lens
- Enclosure rating
- IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions)
- Center box
- Expandable-contractible measurement box with MIN-MAX-AVG temp display
- Electromagnetic compatibility
- IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A
- Australian RCM
- IEC 61326-1
- Weight (battery included)
- 1.04 kg (2.3 lb)
- Supported languages
- Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish
- Operating temperature
- -10 °C to +50 °C (14 °F to 122 °F)
- Laser pointer
- Yes
- Relative humidity
- 10% to 95% non-condensing
- Frame rate
- 60 Hz or 9 Hz versions
- Standard palettes
- 8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
- US FCC
- CFR 47, Part 15 Subpart B
- Color alarms (temperature alarms)
- High temperature, low temperature, and isotherms (within range)
- Safety
- IEC 61010-1: Overvoltage category II, Pollution Degree 2
- Vibration
- 0.03 g2/Hz (3.8 g), 2.5 g IEC 68-2-6
- Shock
- 25 g, IEC 68-2-29
IR-Fusion
- Picture-In-Picture (PIP)
- Yes
- Built-in digital camera (visible light)
- 5 MP
- AutoBlend™ mode
- Min, Mid, Max IR plus full visible on camera; continously variable in software
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther