Fluke 1750/B
1 / 1
- Part Number
- Fluke 1750/B
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Technical Specifications
- Power quality measurement standards Conformance
- IEC 61999-1-4 Class 1, IEC 61000-4-30 Class A or B depending on measurement function, IEEE519, IEEE1159, IEEE1459 and EN50160
- Power quality measurement standards Clock/calendar
- Leap years, 24-hour clock
- Power quality measurement standards Real-time clock accuracy
- Not more than ±1 s/day
- Power quality measurement standards Internal memory capacity for data
- At least 2 GB
- Power quality measurement standards
- Maximum recording period: At least 31 days || Operating time during interruptions (internal UPS operation): 5 minutes per interruption, 60 minutes total operating time without recharging
- Power quality measurement standards Measurement time control
- Automatic
- Power quality measurement standards Maximum number of events
- Limited only by the size of the internal memory
- Power quality measurement standards Power requirements
- 100 to 240 Vrms ±10%, 47-63 Hz, 40 W
- Power quality measurement standards Dimensions
- 215 x 310 x 35 mm (8.5 x 12.2 x 3.5 in)
- Power quality measurement standards Mass (weight)
- 6.3 kg (14 lb)
- Input Measurement types
- One Phase Plus Neutral, One Phase IT No Neutral, One Phase Split Phase, Three Phase Wye, Three Phase Delta, Three Phase IT, Three Phase High Leg, Three Phase Open Leg, 2 Element Delta, 21/2 Element Wye
- Input Input channels
- Voltage: 4 channels, AC/DC || Current: 5 channels
- Input
- Voltage channels: Input resistance: 2 MΩ || Voltage channels: Input capacitance: < 20 pF || Current input characteristics: 2 Vrms = full scale, 1 MΩ Input Impedance for ferro CTs, low impedance for Flexi-CTs || Measuring method: Simultaneous digital sampling of voltage and current. Digital PLL synchronized sampling, internal frequency reference used during voltage drops.
- Synchronization and sampling PLL-synchronization source
- The PLL synchronizes to the A-N voltage for wye power types, and to the A-B voltage for delta power types. All listed power types can be characterized as either wye or delta.
- Synchronization and sampling PLL lock range
- 42.5 to 69 Hz
- Synchronization and sampling
- Sampling frequency: Voltage and current: 256 samples/cycle Inter-harmonics per IEC 61000-4-7: 2 560 points/10 cycles (50 Hz), 3072 points/12 cycles (60 Hz) Transient Voltage: 5 MHz
- Synchronization and sampling A/D resolution
- Voltage and current: 24 bits || Transient voltage: 14 bits
- Voltage and current measurements
- Voltage measurement range: AC voltage: 1000 Vrms ±10% over range || Voltage measurement range: DC voltage: ±1000 V +10% over range || Voltage crest factor: 3 or less
- Voltage and current measurements Current measurement range
- Depends on current probe used
- Voltage and current measurements Current crest factor
- 4 or less
- RMS voltage Measurement type
- True RMS calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by IEC 61000-4-30.
- RMS voltage
- Measurement uncertainty: AC: ±0.2% reading ±0.1% full scale, above 50 Vrms || Measurement uncertainty: DC: ±0.5% reading ±0.2% full scale, above 50 VDC
- RMS current Measurement type
- True RMS calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards
- Transient voltage (impulse) Measurement type
- Waveshape sampling
- Transient voltage (impulse) Full scale
- 8000 V pk
- Transient voltage (impulse) Sample resolution
- 200 nS
- Transient voltage (impulse)
- Measurement uncertainty: ±5% reading ±20 V (test parameters: 1000 VDC, 1000 Vrms, 100 kHz)
- Voltage swell (rms swell) Measurement type
- True RMS (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines)
- Voltage swell (rms swell) Displayed data
- Amplitude and duration of swell
- Voltage swell (rms swell) Measurement
- Same as rms voltage
- Voltage dip (rms sag) Measurement type
- True RMS (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines)
- Voltage dip (rms sag) Displayed data
- Amplitude and duration of dip or interruption
- Voltage dip (rms sag) Measurement
- Same as rms voltage
- Voltage dropout (interruption) Measurement type
- Same as voltage dip
- LAN interface Connector
- RJ-45
- LAN interface Speed and type
- 10/100 Base-T, auto MDIX
- LAN interface
- Communications protocol: TCP/IP over Ethernet
- Wireless controller interface Connection
- wireless (2.4 GHz radio)
- Wireless controller interface Speed
- up to 700 kbit/second
- Wireless controller interface
- Communications protocol: Bluetooth SPP
Power Measurements
- Power, battery life Measurement type
- True RMS calculated continuously: every cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards
- Frequency Measurement range
- 42.5 to 69 Hz
- Frequency Measurement source
- Same as PLL synchronization source
- Frequency Measurement accuracy
- ±10 mHz (10 to 110% of range, with sine wave)
- Power factor Measurement range
- 0.000 to 1.000
- Power factor Measurement accuracy
- ±1 digit from the calculation of each measured value (±3 digits for total)
- Displacement power factor Measurement method
- Calculated from the phase difference between voltage fundamental and current fundamental
- Displacement power factor Measurement range
- 1.000 (leading) to + 1.000 (lagging)
- Displacement power factor Measurement accuracy
- ±0.5% reading ±2% full scale ±1 digit
- Voltage unbalance and phase sequence Measurement method
- Positive sequence voltage divided by negative sequence voltage, per IEC 61000-4-30
- Harmonic voltage and current
- Analysis window: rectangular
- Harmonic voltage and current Analysis order
- 1st to 50th order
- Harmonic voltage and current Measurement accuracy
- Voltage / Current: 1st to 20th orders: ±0.5% reading ±0.2% full scale, 21st to 50th orders: ±1% reading ±0.3% full scale (current sensor accuracy must be included for current and power)
- Harmonic voltage and current Measurement method
- IEC 61000-4-7
- Inter-harmonic voltage and current (intermediate harmonics)
- Analysis window: rectangular
- Inter-harmonic voltage and current (intermediate harmonics) Analysis orders
- 1.5 to 49.5th order
- Inter-harmonic voltage and current (intermediate harmonics) Measurement method
- IEC 61000-4-7
- Flicker Measurement method
- IEC 61000-4-15 || Plt for 2 hours and PSt for 10 minutes
- Flicker
- Measuring range: 0,1 to 5 (25) depending on voltage level, modulation and frequency
Environmental Specifications
- Environmental
- Operating environment: Indoors or in covered area outdoors, up to 2 000 m altitude || Operating temperature and humidity: 0°C to 40°C, 80% RH max, non-condensing
- Environmental Storage temperature and humidity
- -20°C to 50°C, 80% RH max, non-condensing
- Maximum rated working voltage
- Voltage terminals: 1100 Vrms || Voltage durability: 5550 Vrms AC for 1 minute, between voltage input terminals, voltage input terminals and current probes, and voltage input terminals and case (50/60 Hz, 1 mA sense current)
- Maximum rated working voltage Enclosure protection
- IP30 (per EN 60529)
- Standards EMC
- EN 61326-1:1997+A1:1998 Class A || EN 61000-3-2:1995+A1:1998+A2:1998 || EN 61000-3-3:1995
Other Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther