Fluke

Fluke 718EX 300G

1 / 2
thumbnail
thumbnail
Part Number
Fluke 718EX 300G
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Pressure Measurement Accuracy

Fluke 718Ex 30G Range
-830 mbar to 2 bar (internal sensor)Over pressure: 3x FS
Fluke 718Ex 30G Resolution
0.0001 bar
Fluke 718Ex 30G Accuracy
0.05% FS
Fluke 718Ex 30G Functions
Zero, Min, Max, Hold, Damp
Fluke 718Ex 100G Range
-830 mbar to 2 bar (internal sensor)Over pressure: 2x FS
Fluke 718Ex 100G Resolution
0.001 bar
Fluke 718Ex 100G Accuracy
0.05% FS
Fluke 718Ex 100G Functions
Zero, Min, Max, Hold, Damp
Fluke 718Ex 300G Range
-830 mbar to 20 bar (internal sensor)Over pressure: 375 psi, 25 bar
Fluke 718Ex 300G Resolution
0.0001 bar
Fluke 718Ex 300G Accuracy
0.05% FS
Fluke 718Ex 300G Functions
Zero, Min, Max, Hold, Damp
Fluke 718Ex series Range
Via pressure module connector29 pressure modules, 2.5 mbar to 700 barOver pressure per pressure module specs
Fluke 718Ex series Resolution
Per pressure module specs
Fluke 718Ex series Accuracy
To 0.025% of full span, per pressure module specs
Fluke 718Ex series Functions
Zero, Min, Max, Hold, Damp
Fluke 718Ex series
Source pressure, built in pump range: -820 mbar to full scale

Mechanical and General Specifications

Size (L x W x H)
216 x 94 x 66 mm (with holster)
Weight
Approx. 992 g (with holster)
Warranty
Three years, one year for pump
Shock
1 meter drop test
Vibration
Random, 2 G, 5-500 Hz
Battery type
One 9-volt alkaline battery ANSI/NEDA 1604A or IEC 6LR619V
Battery life
4 to 20 hours, depending on functions used

Technical Data

Measure accuracy Range
0-24 mA
Measure accuracy Resolution
0.001 mA
Measure accuracy Accuracy
0.02% rdg ±2 counts
Display
LCD, 5 digit pressure and current simultaneous

Safety Specifications

Safety
ATEX II 1G Ex ia IIC T4 compliant || CSA Certification I.S. Class I || Div 1 Groups A-D , T4

Environmental Specifications

Operating temperature
-10°C to 55°C
Storage temperature
-40°C to 60°C
Humidity (without condensation)
95% (10°C to 30°C) || 75% (30°C to 40°C) || 45% (40°C to 50°C) || 35% (50°C to 55°C)
Operating altitude
3,000 m max

Documents

Data Sheet

Download