Fluke

FLUKE 726

1 / 2
thumbnail
thumbnail
Part Number
FLUKE 726
UPC
095969293273
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

RTDs and Thermocouples

Measure and source accuracy Cu10
1.8°C
Measure and source accuracy NI-120
0.15°C
Measure and source accuracy PT-100 (385)
0.45°C
Measure and source accuracy PT-100 (392)
0.35°C
Measure and source accuracy PT-100 (391-JIS)
0.35°C
Measure and source accuracy PT-200 (385)
0.95°C
Measure and source accuracy PT-500 (385)
0.55°C
Measure and source accuracy PT-1000 (385)
0.35°C
Measure and source accuracy RTD Resolution
0.01°C (0.01°F)
Measure and source accuracy Cu10.01 C
0.1°C (0.1°F)
Measure and source accuracy J
0.4°C
Measure and source accuracy K
0.5°C
Measure and source accuracy T
0.4°C
Measure and source accuracy E
0.4°C
Measure and source accuracy R
1.4°C
Measure and source accuracy S
1.4°C
Measure and source accuracy B
1.4°C
Measure and source accuracy L
0.45°C
Measure and source accuracy U
0.45°C
Measure and source accuracy N
0.6°C
Measure and source accuracy XK
0.4°C
Measure and source accuracy BP
1.1°C
Measure and source accuracy TC Resolution
J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F

Source Accuracy

Voltage DC
100.00 mV: 0.01% + 10 μV || 20.000 V: 0.01% + 2 mV || -10.00 mV to 75.00 mV: 0.025% + 1 count (via TC connector)
Current DC
24.000 mA (Source): 0.01% + 2 μA || 24.000 mA (Simulate): 0.01% + 2 μA
Resistance
Range, accuracy (percent of reading + floor) and excitation current: 5 to 400 Ω, 0.015% + 0.1 Ω, 0.1 to 0.5 mA || Range, accuracy (percent of reading + floor) and excitation current: 5 to 400 Ω, 0.015% + 0.05 Ω, 0.5 to 3 mA || Range, accuracy (percent of reading + floor) and excitation current: 400 to 1500 Ω, 0.015% + 0.5 Ω, 0.05 to 0.8 mA || Range, accuracy (percent of reading + floor) and excitation current: 1500 to 4000 Ω, 0.015% + 0.5 Ω, 0.05 to 0.4 mA
Frequency
2.0 to 1000.0 CPM: 0.05% || 1.0 to 1000.0 Hz: 0.05% || 1.0 to 10.0 kHz: 0.25% || 10.0 to 15.0 kHz: 0.5%
Frequency Waveform
5 V p-p squarewave, -0.1 V offset

Mechanical and General Specifications

Size
200 x 96 x 47 mm (7.9 x 3.8 x 1.9 in)
Weight
650 g (23 oz)
Batteries
4 AA alkaline batteries
Battery replacement
Separate battery compartment, accessible without breaking calibration seal
Side port connections
Pressure module connector, also used for remote real-time programming

Measurement Accuracy

Voltage DC
30.000 V: 0.01% + 2 mV (upper display) || 20.000 V: 0.01% + 2 mV (lower display) || 90.00 mV: 0.01% + 10 μV || -10.00 mV to 75.00 mV: 0.025% + 1 count (via TC connector)
Current DC
24.000 mA: 0.01%+ 2 mA
Resistance
0.0 to 4000.0 Ω: ± 0.015%
Frequency
2.0 to 1000.0 CPM: 0.05% + 0.1 cpm || 1.0 to 1000.0 Hz: 0.05% + 0.1 Hz || 1.00 to 15.00 kHz: 0.05% + 0.01 kHz
Frequency Sensitivity
1 V peak-to-peak-minimum
Pressure
Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.

Specifications

Ramp functions Source functions
Voltage, current, resistance, frequency, temperature
Ramp functions Ramps
Slow ramp, Fast ramp, 25% step-ramp
Loop power function
Voltage: 24 V
Loop power function Accuracy
10%
Loop power function Maximum current
22 mA, short circuit protected
Step functions Source functions
Voltage, current, resistance, frequency, temperature
Step functions Steps
25% of range, 100% of range

Safety Specifications

Agency approvals
EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992

Environmental Specifications

Operating temperature
-10°C to +55°C
Storage temperature
-20°C to +71°C
Operating altitude
3000 m

Documents

Data Sheet

Download