Fluke
Fluke i2000 Flex
1 / 1
- Part Number
- Fluke i2000 Flex
Payment methods:
- Best offer from:
- Trusted Automa.Net Supplier
- Availability:
- 1 pc.In-StockUpdated at: 21-11-2024
- Estimated Delivery:
- On Request
- Condition:
- New Surplus
New Surplus - A new, unused, undamaged item without a manufacturer guarantee. The item may come without original packaging or in replacement packaging. If provided, the box may have been opened.
Shipping Information
Secure Payment Process
Return & Refund Policies
Shipping Policies
Warranty Policies
Electrical specifications
- Current ranges
- 20 A200 A2000 AAC rms
- Output sensitivity (AC-coupled)
- 1 mV10 mV100 mV1 mV per A
- Load impedance
- 100 kΩ minimum
- Accuracy
- at +25°C±1% of range (45 Hz to 65 Hz)
- Linearity
- 10% to 100% of range±0.2% of reading
- Noise
- 8 mV AC rms (30 A)2 mV AC rms (300 A, 3000 A)
- Frequency range
- 10 Hz to 20 kHz (-3 dB)
- Phase error
- < ±1° (45 Hz to 65 Hz)±10° (at 20 kHz)
- Position sensitivity
- with cable > 25 mm from the coupling±2% of range
- External field
- with cable > 200 mm from the head±1% of range
- Power supply
- 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
- Temperature Coefficient
- ±0.08% of reading per °C
- Working voltage
- see Safety standards section600 V AC rms or DC
General Specifications
- Head Circumference
- 610 mm (24 in)
- Head cable diameter
- 14.3 mm (0.56 in)
- Head bend radius
- 38.1 mm (1.5 in)
- Cable length (head to electronics)
- 2 m (6.56 ft)
- Output connection
- Molded 4 mm safety plugs (not integrated)
- Operating temperature range
- 0°C to +70°C (32°F to 158°F) (head and electronics)
- Storage temperature range
- -40°C to +105°C (-40°F to 221°F) (head)-20°C to +85°C (-4°F to 185°F) (electronics)
- Operating humidity
- 15% to 85% (non-condensing)
- Weight
- 180 g (6.34 oz) (head)190 g (6.70 oz) (electronics)
- Safety standards
- EN 61010-031: 2002EN 61010-2-032: 2002EN 61010-1: 2001600 Vrms, Category III, Pollution Degree 2Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz.
- EMC standards
- EN 61326: 1998 +A1, A2, and A3
- Dimensions (H x W x D)
- 116 x 68.5 x 30 mm (4.56 x 2.69 x 1.18 in)
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther