Fluke

Fluke i430

1 / 1
thumbnail
Part Number
Fluke i430
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

General Specifications

Probe and cable material
R 1/14
Couplings material
Polypropylene, UL94 V-0
Probe cable length
610 mm
Probe cable diameter
12.4 mm
Probe cable bend radius
40 mm
Output cable length
2.5 meters RG58
Output connector
Safety BNC Connector
Operating range
-20 to +90°C
Storage temperature
-40 to +105°C
Operating humidity
15% to 85% (non condensing)
Degree of protection (Probe)
IP41

Specifications

Current range
3000 A AC rms
Voltage output (@ 1000 A rms, 50 Hz)
85 mV
Accuracy
(@ 25°C, 50 Hz)
Linearity (10% to 100% of range)
±0.2% of reading
Noise (10 Hz – 7 kHz)
1.0 mV AC rms
Output impedance
82 Ω min
Load impedance
50 kΩ
Internal Resistance per 100 mm probe length
10.5Ω ±5%
Bandwidth (-3dB)
10 Hz to 7 kHz
Phase error (45 – 65 Hz)
±1°
Position sensitivity
±2% of reading max.
Temperature coefficient
±0.08% max of reading per °C
Working voltage (see Safety standards section)
30 V max. (output)

Safety Specifications

Safety standards
Safety rating for the output to earth is limited to 600 V AC rms or DC.