Fluke
Fluke Norma 5000
1 / 3
- Part Number
- Fluke Norma 5000
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Standards and Safety
- Electrical Safety
- EN 61010-1 / 2nd Edition 1000 V CAT II (600V CAT III) || Degree of pollution 2, safety Class I || EN 61558 for transformer || EN 61010-2-031/032 for accessories
- Maximum inputs
- For voltage inputs Measurement range 1000 Veff, 2 kVpeak || For current inputs Measurement range 10 Aeff, 20 Apeak
- Test voltage
- Net input: case (protective conductor): 1.5 KV AC || Measurement inputs: Case: 3.3 kV AC || Measurement input: input: 5.4 kV
- Test voltage Net connection
- Measurement input: 5.4 kV AC
- Electromagnetic susceptibility Emission
- IEC 61326-1, EN 50081-1, EN 55011 Class B
- Electromagnetic susceptibility
- Immunity: IEC 61326-1 / Annex A (industrial sector), EN 50082-1
Interface
- Options
- IEEE 488.2 / 1 MBit/s || Ethernet / 10 MBit/s or 100 Mbit/s
Ambient Conditions
- Working Temperature Range
- 5°C to 35°C (41°F to 95°F)
- Storage Temperature Range
- -20°C to 50°C (-4°F to 122°F)
- Housing Material
- Fluke Norma Power Analyzers are extremely compact and equipped with a solid metal case to meet stringent EMC requirements.
- Climatic Class
- KYG DIN 40040, max. 85% relative humidity, non-condensing.
- Power supply
- 85 V AC to 264 V AC, 50 Hz to 60 Hz, DC 100 to 260 V, ca. 40 VA European plug with switch. Binding post for current available on some models.
- Measuring Inputs
- Safety sockets 4 mm, 2 for each input. External shunt connection over BNC socket.
- Operation
- Membrane keyboard with cursor – function keys and direct functions.
- Connections
- Rear panel of the 3-phase Analyzer
Planarshunt
- Continuous load (Imin)Range (Imax)
- 0.3 A
- Continuous load (Imin)
- 32 A
- Nominal current (calibration point)
- 32 A
- Basic accuracy at calibration point [%]
- ± 0.03
- Basic accuracy at nominal current [%]
- ± 0.03
- Nominal voltage drop [V]
- 320 mV
- Nominal resistance [Ohm]
- 10 mΩ
- Short time overrange(5s load 15s interval)
- 100A/ 1s-5s
- Bandwidth
- DC - 1 MHz
- Angular accuracy [°/kHz]
- ± 0.1
- Temperature coefficient [ppm/K]
- ≤10
- Weight (kg / lbs)
- 0.62 /1.36
Basic Functions
- Fast Fourier Transformation (FFT)
- Calculation of harmonics with graphical representation. Up to 3 bar graphs are displayed at the same time. || Measured values: U, I, P per phase || Order: 1st to 40th harmonics, maximum half sample frequency
- Digital Oscilloscope (DSO)
- Simultaneous display of up to 3 measured values on sample level. Quick view of curve form and distortion.
- Integration function (energy)
- Simultaneous display of up to 6 configurable numeric values. Start/Stop conditions and positive negative direction available.
- Vector Display
- Vector display of HO1 up to 6 signals. For easy testing of the right connection of the instrument and quick overview of the phase angle of each signal.
- Recorder
- Display of average values over time for trend determination.
- RAM data memory
- Storing of sample and average values; setting of start and stop conditions. || From the RAM approximately 4 MB are available for the storage of measured values.
- Configuration
- Set up the analyzer to measure and display data in the format required.
Frequency and Synchronization
- Range
- DC and 0.2 Hz to sample rate
- Accuracy
- ±0.01% of measured value (reading)
Power Phase Channels
- PP42 Accuracy
- 0.2% (0.1% rd + 0.1% rg)
- PP42 Current range
- 20 A
- PP42
- Sampling rate: 341 kHz
- PP42 Bandwidth
- 3 MHz
- PP50 Accuracy
- 0.1% (0.05% rd + 0.05% rg)
- PP50 Current range
- 10 A
- PP50
- Sampling rate: 1 MHz
- PP50 Bandwidth
- 10 MHz
- PP54 Accuracy
- 0.1% (0.05% rd + 0.05% rg)
- PP54 Current range
- 10 A
- PP54
- Sampling rate: 341 kHz
- PP54 Bandwidth
- 3 MHz
- PP64 Accuracy
- 0.03% (0.02% rg + 0.01% rg)
- PP64 Current range
- 10 A
- PP64
- Sampling rate: 341 kHz
- PP64 Bandwidth
- 3 MHz
General Specifications
- Number of Phases
- 1 to 3
- Weight
- Approx. 5 kg (11 lb)
- Size
- 150 x 237 x 315 mm || 5.9 x 9.3 x 12.4 in
- On-board Printer
- No
- Display
- Color, 5.7 in / 144 mm - 320 x 240 pixel || User-selectable background lighting and contrast.
- Bandwidth
- DC to 3 MHz or DC to 10 MHz depending on input module
- Basic Accuracy
- 0.2%, 0.1% or 0.03% depending on input modules
- Sampling Rate
- 0.33 MHz or 1 MHz depending on input modules
- Voltage Input Range
- 0.3 V to 1000 V
- Current Input Range (direct, not via shunt)
- 0.03 mA to 20 A depending on input module
- Memory for Configurations
- 4 MB
- Memory for Settings
- 0.5 MB
- Fast Fourier Transformation (FFT)
- To the 40th harmonic
- RS232/USB Interface
- Standard
- PI1 Process interface (8 analog/impulse inputs and 4 analog outputs)
- Optional
- IEEE 488.2/GPIB interface (1 MBit/s Ethernet / 10 MBit/s or 100 MBit/s)
- Optional
- Fluke NormaView PC software (for data download, analysis and report writing)
- Standard
Documents
Data Sheet
DownloadOther Categories
ActuatorsBlocksCables, Pipes & HosesCompressorsControlCouplings & FittingsCylinders & PistonsElectronicsFiltersHVACIndustrial PC's & HMIsLightingLinear techniqueMotorsPower SupplyPower TransmissionPumps & ValvesRenewable energyRoboticsSeals, Rings & ConnectorsSensors & Measuring DevicesTools and AccessoriesCNCOther