Fluke

Fluke Norma 5000

1 / 3
thumbnail
thumbnail
thumbnail
Part Number
Fluke Norma 5000
  • Get up to 90 days payment terms from 500+ suppliers
  • Reselling discounts up to 40%!
Sign-Up
Send request for price
1
Payment methods:
Request a Quote and we will send you information on availability and price.

Standards and Safety

Electrical Safety
EN 61010-1 / 2nd Edition 1000 V CAT II (600V CAT III) || Degree of pollution 2, safety Class I || EN 61558 for transformer || EN 61010-2-031/032 for accessories
Maximum inputs
For voltage inputs Measurement range 1000 Veff, 2 kVpeak || For current inputs Measurement range 10 Aeff, 20 Apeak
Test voltage
Net input: case (protective conductor): 1.5 KV AC || Measurement inputs: Case: 3.3 kV AC || Measurement input: input: 5.4 kV
Test voltage Net connection
Measurement input: 5.4 kV AC
Electromagnetic susceptibility Emission
IEC 61326-1, EN 50081-1, EN 55011 Class B
Electromagnetic susceptibility
Immunity: IEC 61326-1 / Annex A (industrial sector), EN 50082-1

Interface

Options
IEEE 488.2 / 1 MBit/s || Ethernet / 10 MBit/s or 100 Mbit/s

Ambient Conditions

Working Temperature Range
5°C to 35°C (41°F to 95°F)
Storage Temperature Range
-20°C to 50°C (-4°F to 122°F)
Housing Material
Fluke Norma Power Analyzers are extremely compact and equipped with a solid metal case to meet stringent EMC requirements.
Climatic Class
KYG DIN 40040, max. 85% relative humidity, non-condensing.
Power supply
85 V AC to 264 V AC, 50 Hz to 60 Hz, DC 100 to 260 V, ca. 40 VA European plug with switch. Binding post for current available on some models.
Measuring Inputs
Safety sockets 4 mm, 2 for each input. External shunt connection over BNC socket.
Operation
Membrane keyboard with cursor – function keys and direct functions.
Connections
Rear panel of the 3-phase Analyzer

Planarshunt

Continuous load (Imin)Range (Imax)
0.3 A
Continuous load (Imin)
32 A
Nominal current (calibration point)
32 A
Basic accuracy at calibration point [%]
± 0.03
Basic accuracy at nominal current [%]
± 0.03
Nominal voltage drop [V]
320 mV
Nominal resistance [Ohm]
10 mΩ
Short time overrange(5s load 15s interval)
100A/ 1s-5s
Bandwidth
DC - 1 MHz
Angular accuracy [°/kHz]
± 0.1
Temperature coefficient [ppm/K]
≤10
Weight (kg / lbs)
0.62 /1.36

Basic Functions

Fast Fourier Transformation (FFT)
Calculation of harmonics with graphical representation. Up to 3 bar graphs are displayed at the same time. || Measured values: U, I, P per phase || Order: 1st to 40th harmonics, maximum half sample frequency
Digital Oscilloscope (DSO)
Simultaneous display of up to 3 measured values on sample level. Quick view of curve form and distortion.
Integration function (energy)
Simultaneous display of up to 6 configurable numeric values. Start/Stop conditions and positive negative direction available.
Vector Display
Vector display of HO1 up to 6 signals. For easy testing of the right connection of the instrument and quick overview of the phase angle of each signal.
Recorder
Display of average values over time for trend determination.
RAM data memory
Storing of sample and average values; setting of start and stop conditions. || From the RAM approximately 4 MB are available for the storage of measured values.
Configuration
Set up the analyzer to measure and display data in the format required.

Frequency and Synchronization

Range
DC and 0.2 Hz to sample rate
Accuracy
±0.01% of measured value (reading)

Power Phase Channels

PP42 Accuracy
0.2% (0.1% rd + 0.1% rg)
PP42 Current range
20 A
PP42
Sampling rate: 341 kHz
PP42 Bandwidth
3 MHz
PP50 Accuracy
0.1% (0.05% rd + 0.05% rg)
PP50 Current range
10 A
PP50
Sampling rate: 1 MHz
PP50 Bandwidth
10 MHz
PP54 Accuracy
0.1% (0.05% rd + 0.05% rg)
PP54 Current range
10 A
PP54
Sampling rate: 341 kHz
PP54 Bandwidth
3 MHz
PP64 Accuracy
0.03% (0.02% rg + 0.01% rg)
PP64 Current range
10 A
PP64
Sampling rate: 341 kHz
PP64 Bandwidth
3 MHz

General Specifications

Number of Phases
1 to 3
Weight
Approx. 5 kg (11 lb)
Size
150 x 237 x 315 mm || 5.9 x 9.3 x 12.4 in
On-board Printer
No
Display
Color, 5.7 in / 144 mm - 320 x 240 pixel || User-selectable background lighting and contrast.
Bandwidth
DC to 3 MHz or DC to 10 MHz depending on input module
Basic Accuracy
0.2%, 0.1% or 0.03% depending on input modules
Sampling Rate
0.33 MHz or 1 MHz depending on input modules
Voltage Input Range
0.3 V to 1000 V
Current Input Range (direct, not via shunt)
0.03 mA to 20 A depending on input module
Memory for Configurations
4 MB
Memory for Settings
0.5 MB
Fast Fourier Transformation (FFT)
To the 40th harmonic
RS232/USB Interface
Standard
PI1 Process interface (8 analog/impulse inputs and 4 analog outputs)
Optional
IEEE 488.2/GPIB interface (1 MBit/s Ethernet / 10 MBit/s or 100 MBit/s)
Optional
Fluke NormaView PC software (for data download, analysis and report writing)
Standard

Documents

Data Sheet

Download