Need more information?

Call us at:+48 17 778 34 19

ABB 1SBL237201R1300AF26-40-00-13 100-250V50/60HZ-DC Contactor

1 / 2
1SBL237201R1300 ABB, Electronics
Reference Image - Not actual item!
1SBL237201R1300 ABB, Electronics
1SBL237201R1300 ABB, Electronics
1SBL237201R1300 ABB, Electronics

Offer Description

The AF26-40-00-13 is a 4 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 11 kW / 400 V AC (AC-3) and switching power circuits up to 45 A (AC-1) or 45 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.AF26-40-00-13 100-250V50/60HZ-DC Contactor ABB 1SBL237201R1300

Product Description

The AF26-40-00-13 is a 4 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 11 kW / 400 V AC (AC-3) and switching power circuits up to 45 A (AC-1) or 45 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Product Details

Brand
ABB
Country of Origin
FR
Part Number
1SBL237201R1300
Tariff Code
85364900
EAN
3471523115231
UNSPSC
39121529
ETIM
Group Code : EG000017
Group Description : Low-voltage Industrial Components
Class Description : Power contactor, AC switching
Class Code : EC000066
Version : 7
$147.22
excl. tax
Free Shipping!

Offer details

Best offer from:
Trusted Automa.Net Supplier
Availability:
3 pcs.
In-Stock
Updated at: 18-07-2025
Warranty:
12 months
Estimated Delivery:
25-30 July to United States
Condition:
New Factory Sealed
New Factory Sealed - A brand-new, unused, unopened, undamaged item in its original manufacturer-sealed packaging.
The Seller is responsible for shipping the product and invoicing

Are you a Supplier?

Join 650 suppliers, sell to 3500+ verified buyers.

Sign up now

Policies and Information

Shipping Information

Return & Refund Policies

Secure Payment Process

Warranty Policies

Dimensions

Product Net Width
45 mm
Product Net Depth / Length
101 mm
Product Net Height
86 mm
Product Net Weight
0.36 kg

Technical

Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Main Circuit 690 V
Rated Frequency (f)
Control Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 55 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 45 A(690 V) 60 °C 40 A(690 V) 70 °C 32 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 21.2 A(440 V) 60 °C 20 A(500 V) 60 °C 17.6 A(690 V) 60 °C 10.5 A(380 / 400 V) 60 °C 22 A(220 / 230 / 240 V) 60 °C 23.2 A
Rated Operational Power AC-3 (Pe)
(400 V) 11 kW(415 V) 11 kW(440 V) 11 kW(500 V) 11 kW(690 V) 9 kW(220 / 230 / 240 V) 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour
Rated Operational Current DC-1 (Ie)
(110 V) 2 Poles in Series, 40 °C 45 A(110 V) 2 Poles in Series, 60 °C 40 A(110 V) 2 Poles in Series, 70 °C 32 A(110 V) 3 Poles in Series, 40 °C 45 A(110 V) 3 Poles in Series, 60 °C 40 A(110 V) 3 Poles in Series, 70 °C 32 A(110 V) 4 Poles in Series, 40 °C 45 A(110 V) 4 Poles in Series, 60 °C 40 A(110 V) 4 Poles in Series, 70 °C 32 A(220 V) 3 Poles in Series, 40 °C 45 A(220 V) 3 Poles in Series, 60 °C 40 A(220 V) 3 Poles in Series, 70 °C 32 A(220 V) 4 Poles in Series, 40 °C 45 A(220 V) 4 Poles in Series, 60 °C 40 A(220 V) 4 Poles in Series, 70 °C 32 A(72 V) 1-Pole, 40 °C 45 A(72 V) 1-Pole, 60 °C 40 A(72 V) 1-Pole, 70 °C 32 A(72 V) 2 Poles in Series, 40 °C 45 A(72 V) 2 Poles in Series, 60 °C 40 A(72 V) 2 Poles in Series, 70 °C 32 A(72 V) 3 Poles in Series, 40 °C 45 A(72 V) 3 Poles in Series, 60 °C 40 A(72 V) 3 Poles in Series, 70 °C 32 A(72 V) 4 Poles in Series, 40 °C 45 A(72 V) 4 Poles in Series, 60 °C 40 A(72 V) 4 Poles in Series, 70 °C 32 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 msBetween Coil De-energization and NO Contact Opening 11 ... 95 msBetween Coil Energization and NC Contact Opening 38 ... 90 msBetween Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 1.5 ... 16 mm²Flexible with Insulated Ferrule 1/2x 1.5 ... 16 mm²Rigid Solid 1/2x 1.5 ... 4 mm²Rigid Stranded 1/2x 1.5 ... 16 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Control Circuit 10 mmMain Circuit 12 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type
Screw Terminals

Classifications

Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
EClass
V11.0 : 27371003
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3705830
E-Number (Sweden)
3211511

Environmental

Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Vibrations acc. to IEC 60068-2-6
5 ... 300 Hz 4 g closed position / 2 g open position
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 gOpen, Shock Direction: B1 5 gShock Direction: A 30 gShock Direction: B2 15 gShock Direction: C1 25 gShock Direction: C2 25 g
RoHS Status
Following EU Directive 2011/65/EU

Technical UL/CSA

Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 45 A
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 16-10 AWGRigid Stranded 1/2x 16-6 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Control Circuit 11 in·lbMain Circuit 22 in·lb

Ordering

Minimum Order Quantity
1 piece
Customs Tariff Number
85364900

Related products

1SDA054859R1 ABB, Other
1SDA054859R1
ABB
TC-FP T5 400/630 3p TER.COV.FIXED/P 2pcs
1SDA073770R1 ABB, Other
1SDA073770R1
ABB
RTC 250VAC E1.2-XT7M
05330 ABB, Cables
05330
ABB
WIRING DUCT PVC HOLES 18 23 50X50
1SDA071652R1 ABB, Other
1SDA071652R1
ABB
E2.2B 2000 Ekip Dip LSI 4p F HR
1SDA072919R1 ABB, Circuit Breakers
1SDA072919R1
ABB
E2.2S 1000 Ekip Hi-Touch LSIG 4p WMP
1SDA073022R1 ABB, Circuit Breakers
1SDA073022R1
ABB
E2.2S 2000 Ekip Dip LSI 4p WMP
1SDA073545R1 ABB, Other
1SDA073545R1
ABB
E4.2H/MS 4000 4p WMP
1SDA072013R1 ABB, Circuit Breakers
1SDA072013R1
ABB
E6.2H/f 6300 Ekip Dip LSIG 4p F HR
1SDA072659R1 ABB, Circuit Breakers
1SDA072659R1
ABB
E6.2V 6300 Ekip Hi-Touch LSIG 3p WMP
2TLA022301R0300 ABB, Other
2TLA022301R0300
ABB
Orion1-4-14-060-E Light Curtain
EA2360 ABB, Other
EA2360
ABB
IS2-EA2360 Control and Automation Board
EC2280VC4K ABB, Control Cabinets
EC2280VC4K
ABB
IS2-EC2280VC4K Control and Automation Board
BCG-M632 ABB, Other
BCG-M632
ABB
NP BRASS CG M63X1.5 34-44MM
1SDA054602R1 ABB, Other
1SDA054602R1
ABB
T5D 630 4p F F
1SDA059145R1 ABB, Other
1SDA059145R1
ABB
TOROID TRANSFOR. x PR122/123 E1-6 new-T8