- Number of Main Contacts NO
- 3
- Number of Main Contacts NC
- 0
- Number of Auxiliary Contacts NO
- 1
- Number of Auxiliary Contacts NC
- 1
- Rated Operational Voltage
- Auxiliary Circuit 690 VMain Circuit 1000 V DC
- Rated Frequency (f)
- Auxiliary Circuit 50 / 60 HzControl Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith)
- acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 Aacc. to IEC 60947-5-1, Θ = 40 °C 16 A
- Rated Operational Current AC-15 (Ie)
- (500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(380 / 400 V) 3 A
- Short-Circuit Protective Devices
- Auxiliary Circuit - gG Type Fuses 10 AgG Type Fuses 160 A
- Rated Short-time Withstand Current Low Voltage (Icw)
- for 0.1 s 140 Afor 1 s 100 A
- Maximum Electrical Switching Frequency
- 300 cycles per hour
- Rated Operational Current DC-1 (Ie)
- (1000 V) 1-Pole, 40 °C 35 A(1000 V) 1-Pole, 55 °C 35 A(1000 V) 1 Pole, 70 °C 35 A(110 V) 1-Pole, 40 °C 120 A(110 V) 1-Pole, 55 °C 100 A(110 V) 1-Pole, 70 °C 85 A(220 V) 1-Pole, 40 °C 120 A(220 V) 1-Pole, 55 °C 100 A(220 V) 1-Pole, 70 °C 85 A(440 V) 1-Pole, 40 °C 100 A(440 V) 1-Pole, 55 °C 100 A(440 V) 1-Pole, 70 °C 85 A(600 V) 1-Pole, 40 °C 75 A(600 V) 1-Pole, 55 °C 75 A(600 V) 1-Pole, 70 °C 75 A(72 V) 1-Pole, 40 °C 120 A(72 V) 1-Pole, 55 °C 100 A(72 V) 1-Pole, 70 °C 85 A
- Rated Operational Current DC-3 (Ie)
- (110 V) 1-Pole, 40 °C 120 A(110 V) 1-Pole, 55 °C 100 A(220 V) 1-Pole, 40 °C 100 A(220 V) 1-Pole, 55 °C 100 A(440 V) 1-Pole, 40 °C 85 A(440 V) 1-Pole, 55 °C 85 A(72 V) 1-Pole, 40 °C 120 A(72 V) 1-Pole, 55 °C 100 A
- Rated Operational Current DC-5 (Ie)
- (110 V) 1-Pole, 40 °C 85 A(110 V) 1-Pole, 55 °C 85 A(220 V) 1-Pole, 40 °C 85 A(220 V) 1-Pole, 55 °C 85 A(440 V) 1-Pole, 40 °C 35 A(440 V) 1-Pole, 55 °C 35 A(72 V) 1-Pole, 40 °C 85 A(72 V) 1-Pole, 55 °C 85 A
- Rated Operational Current DC-13 (Ie)
- (24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.30 A / 66 W(250 V) 0.3 / 75 W
- Rated Insulation Voltage (Ui)
- acc. to IEC 60947-4-1 1000 Vacc. to IEC 60947-5-1 690 Vacc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp)
- 8 kV
- Mechanical Durability
- 10 million
- Maximum Mechanical Switching Frequency
- 3600 cycles per hour
- Rated Control Circuit Voltage (Uc)
- 50 Hz 110 V60 Hz 110 ... 120 V
- Coil Consumption
- Average Holding Value 50 / 60 Hz 18 V·AAverage Pull-in Value 50 Hz 190 V·AAverage Pull-in Value 60 Hz 180 V·AHolding at Max. Rated Control Circuit Voltage 50 Hz 18 V·AHolding at Max. Rated Control Circuit Voltage 50 Hz 5.5 WHolding at Max. Rated Control Circuit Voltage 60 Hz 18 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 5.5 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 210 V·A
- Operate Time
- Between Coil De-energization and NC Contact Closing 7 ... 14 msBetween Coil De-energization and NO Contact Opening 4 ... 11 msBetween Coil Energization and NC Contact Opening 7 ... 22 msBetween Coil Energization and NO Contact Closing 8 ... 27 ms
- Mounting on DIN Rail
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH75-25 (75 x 25 mm Mounting Rail) acc. to IEC 60715
- Mounting by Screws (not supplied)
- 2 x M6 screws placed diagonally
- Connecting Capacity Main Circuit
- Flexible with Cable End 6 ... 16 mm²Rigid Cable 6 ... 25 mm²
- Connecting Capacity Auxiliary Circuit
- Flexible with Cable End 0.75 ... 2.5 mm²Rigid Cable 1 ... 4 mm²
- Degree of Protection
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
- Connecting Terminals (delivered in open position) Main Poles
- M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
- Terminal Type
- Screw Terminals